The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Fast, Ultrasensitive Virus Detection Using a Young Interferometer Sensor
Abstract
We report the application of an integrated optical Young interferometer sensor for ultrasensitive, real-time, direct detection of viruses. We have validated the sensor by detecting herpes simplex virus type 1 (HSV-1), but the principle is generally applicable. Detection of HSV-1 virus particles was performed by applying the virus sample onto a sensor surface coated with a specific antibody against HSV-1. The performance of the sensor was tested by monitoring virus samples at clinically relevant concentrations. We show that the Young interferometer sensor can specifically and sensitively detect HSV-1 at very low concentrations (850 particles/mL). We have further demonstrated that the sensor can specifically detect HSV-1 suspended in serum. Extrapolation of the results indicates that the sensitivity of the sensor approaches the detection of a single virus particle binding, yielding a sensor of unprecedented sensitivity with wide applications for viral diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prognosis in HIV-1 Infection Predicted by the Quantity of Virus in Plasma
Mellors, J. W., Rinaldo, C. R., Gupta, P., White, R. M., Todd, J. A., & Kingsley, L. A. (1996) · Science · doi:10.1126/science.272.5265.1167 · Cited by 2,660
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
High Levels of HIV-1 in Plasma During All Stages of Infection Determined By Competitive PCR
Piatak, M., Saag, M. S., Yang, L. C., Clark, S. J., Kappes, J. C., Luk, K.-C., Hahn, B. H., Shaw, G. M., & Lifson, J. D. (1993) · Science · doi:10.1126/science.8096089 · Cited by 1,237
Regulation of T Cell Receptor Signaling by Tyrosine Phosphatase SYP Association with CTLA-4
Marengère, L. E. M., Waterhouse, P., Duncan, G. S., Mittrücker, H.-W., Feng, G.-S., & Mak, T. W. (1996) · Science · doi:10.1126/science.272.5265.1170 · Cited by 551
Virus detection using nanoelectromechanical devices
Ilic, B., Yang, Y., & Craighead, H. G. (2004) · Applied Physics Letters · doi:10.1063/1.1794378 · Cited by 365
Heideman, R. G., & Lambeck, P. V. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00283-x · Cited by 331
Self-citationPachl, C. A., Todd, J. A., Kern, D. G., Sheridan, P. J., Fong, S.-J., Stempien, M. M., Hoo, B., Besemer, D. J., Yeghiazarian, T., Irvine, B. D., et al. (1995) · Journal of Acquired Immune Deficiency Syndromes & Human Retrovirology · doi:10.1097/00042560-199504120-00003 · Cited by 232
A new quantitative optical biosensor for protein characterisation
Cross, G. H., Reeves, A. A., Brand, S., Popplewell, J. F., Peel, L. L., Swann, M. J., & Freeman, N. J. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00203-3 · Cited by 219
Requirement of the Carboxyl Terminus of a Bacterial Chemoreceptor for Its Targeted Proteolysis
Alley, M. R. K., Maddock, J. R., & Shapiro, L. (1993) · Science · doi:10.1126/science.8456303 · Cited by 113
Realization of a multichannel integrated Young interferometer chemical sensor
Ymeti, A., Kanger, J. S., Greve, J., Lambeck, P., Wijn, R. R., & Heideman, R. (2003) · Applied Optics · doi:10.1364/ao.42.005649 · Cited by 107
Self-citation
Cited by
Sensitive optical biosensors for unlabeled targets: A review
Fan, X., White, I. M., Shopova, S. I., Zhu, H., Suter, J. D., & Sun, Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.05.022 · Cited by 2,187
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
McDonagh, C., Burke, C. S., & MacCraith, B. D. (2008) · Chemical Reviews · doi:10.1021/cr068102g · Cited by 1,026
Integrated optical devices for lab‐on‐a‐chip biosensing applications
Estevez, M. C., Alvarez, M., & Lechuga, L. M. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100025 · Cited by 617
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Benelli, G. (2016) · Parasitology Research · doi:10.1007/s00436-015-4800-9 · Cited by 539
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Terahertz plasmonics: The rise of toroidal metadevices towards immunobiosensings
Ahmadivand, A., Gerislioglu, B., Ahuja, R., & Kumar Mishra, Y. (2020) · Materials Today · doi:10.1016/j.mattod.2019.08.002 · Cited by 373
Metasurface Micro/Nano-Optical Sensors: Principles and Applications
Qin, J., Jiang, S., Wang, Z., Cheng, X., Li, B., Shi, Y., Tsai, D. P., Liu, A. Q., Huang, W., & Zhu, W. (2022) · ACS Nano · doi:10.1021/acsnano.2c03310 · Cited by 359
Femtosecond laser microstructuring: an enabling tool for optofluidic lab‐on‐chips
Osellame, R., Hoekstra, H. J. W. M., Cerullo, G., & Pollnau, M. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.201000031 · Cited by 320
So, H., Park, D., Jeon, E., Kim, Y., Kim, B. S., Lee, C., Choi, S. Y., Kim, S. C., Chang, H., & Lee, J. (2008) · Small · doi:10.1002/smll.200700664 · Cited by 288
Carlborg, C. F., Gylfason, K. B., Kaźmierczak, A., Dortu, F., Bañuls Polo, M. J., Maquieira Catala, A., Kresbach, G. M., Sohlström, H., Moh, T., Vivien, L., et al. (2010) · Lab Chip · doi:10.1039/b914183a · Cited by 275
Highly sensitive fluorescence detection system for microfluidic lab-on-a-chip
Ryu, G., Huang, J., Hofmann, O., Walshe, C. A., Sze, J. Y. Y., McClean, G. D., Mosley, A., Rattle, S. J., deMello, J. C., deMello, A. J., et al. (2011) · Lab on a Chip · doi:10.1039/c0lc00586j · Cited by 93
Metadata
- Authors
- Ymeti, A., Greve, J., Lambeck, P. V., Wink, T., van Hövell, Beumer, Wijn, R. R., Heideman, R. G., Subramaniam, V., & Kanger, J. S.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-12-29
- Volume
- 7
- Issue
- 2
- Pages
- 394-397
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2023282503
- Cited by
- 287
- References
- 10
- FWCI
- 10.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.