CoChat

Modulation of Complement Activation and Amplification on Nanoparticle Surfaces by Glycopolymer Conformation and Chemistry

Yu, Kai, Lai, Benjamin F. L., Foley, Jonathan H., Krisinger, Michael J., Conway, Edward M., Kizhakkedathu, Jayachandran N. · 2014 · ACS Nano
Cited by 79

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

The complement system plays an integral part of a host's innate immunity, and its activation is highly dependent on the chemistry and structure of a "foreign" target surface. We determined that the conformational state of glycopolymer chains, defined by the grafting density (chains/nm(2)), on the nanoparticle (NP) surface acts as a "molecular switch" for complement activation and amplification, and the protein corona on the NP surface dictates this process. A grafting density threshold was determined, below which minimal complement activation was observed and above which substantial complement activation was detected. The glycopolymer-grafted NPs activated complement via the alternative pathway. The chemical structure of pendent sugar units on the grafted polymer was also an important determinant for complement activation. NPs grafted with glucose-containing polymer activated complement at a lower grafting density compared to NPs grafted with galactose-containing polymer. Analysis of complement activation products C3a and SC5b-9 followed a similar pattern. Complement activation on the NP surface was independent of particle size or concentration for a given conformational state of grafted polymer. To gain insight into a putative surface-dependent mechanism of complement activation, we determined the nature of adsorbed protein corona on various NPs through quantitative mass spectrometry. Elevated levels of two pro-complement proteins, factors B and C3, present on the NP surface grafted with glycopolymer chains at high grafting density compared to low grafting density surface, may be responsible for its complement activity. Galactose polymer modified NPs adsorbed more of the negative regulator of complement, factor H, than the glucose surface, providing an explanation for its lower level of complement activation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nn504186b

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Yu, K., Lai, B. F. L., Foley, J. H., Krisinger, M. J., Conway, E. M., & Kizhakkedathu, J. N.
Venue
ACS Nano
Published
2014-08-15
Volume
8
Issue
8
Pages
7687-7703
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W1967782236
Cited by
79
References
8
FWCI
4.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.