CoChat

Elevated Serum IgG4 Levels in Diagnosis, Treatment Response, Organ Involvement, and Relapse in a Prospective IgG4-Related Disease UK Cohort

Open access
Culver, Emma L, Sadler, Ross, Simpson, Dawn, Cargill, Tamsin, Makuch, Mateusz, Bateman, Adrian C, Ellis, Anthony J, Collier, Jane, Chapman, Roger W, Klenerman, P, Barnes, Eleanor, Ferry, Berne · 2016 · American Journal of Gastroenterology
Cited by 225

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Elevated serum immunoglobulin G4 (IgG4) levels have been associated with autoimmune pancreatitis and IgG4-related disease (IgG4-RD) for over a decade. However, an elevated serum IgG4 is not specific for the disease. There have been inconsistent reports of its use in diagnosis, as a marker of disease relapse, and its relationship to organ involvement in retrospective cohorts. The aims of this study were to ascertain conditions that are associated with an elevated serum IgG4 and to investigate the role of IgG4 in diagnosis, relapse, and organ involvement in a prospective cohort of patients with IgG4-RD. METHODS: We evaluated serum IgG4 measurements in the Oxford Immunology Laboratory over 6 years. Patients in whom serum IgG4 was requested to differentiate IgG4-RD from other diseases were recruited into a longitudinal follow-up study to determine final diagnosis. In a prospective cohort of IgG4-RD patients, organ involvement, response to therapy, and disease relapse were determined. RESULTS: Two thousand and sixty-seven samples from 1,510 patients had serum IgG4 measured. Of these, IgG4 was elevated (≥1.4 g l(-1)) in 243 (16.1%) patients. The main indication (85.6%) was to distinguish between IgG4-RD and non-IgG4-RD conditions. Only 5.1% of patients who had serum IgG4 measured for this purpose had a final diagnosis of IgG4-RD. Of those with an elevated serum IgG4, 22.4% met IgG4-RD diagnostic criteria. Serum IgG4 was elevated in 48 (82.8%) of IgG4-RD patients. An IgG4 cutoff of 1.4 g l(-1) gave a sensitivity of 82.8% and specificity of 84.7% to diagnose IgG4-RD. Increasing this to 2.8 g l(-1) increased specificity to 96.2% and negative predictive value to 97.7%, with a lower sensitivity of 56.9% and positive predictive value of 44.5%. Serum IgG4 levels fell with corticosteroid therapy, but this was not disease-specific. A serum IgG4 of ≥2.8 g l(-1) at diagnosis was associated with multi-organ involvement and risk of relapse. CONCLUSIONS: Serum IgG4 levels are elevated in multiple non-IgG4-RD inflammatory and malignant conditions, with less than one-quarter of those with an elevated IgG4 meeting IgG4-RD diagnostic criteria. A serum IgG4 of ≥2.8 g l(-1) is useful in distinguishing between IgG4-RD and non-IgG4-RD diagnoses, predicting multiple-organ involvement and risk of relapse in IgG4-RD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajg.2016.40

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 225

Metadata

Authors
Culver, E. L., Sadler, R., Simpson, D., Cargill, T., Makuch, M., Bateman, A. C., Ellis, A. J., Collier, J., Chapman, R. W., Klenerman, P., Barnes, E., & Ferry, B.
Venue
American Journal of Gastroenterology
Published
2016-05
Volume
111
Issue
5
Pages
733-743
ISSN
0002-9270 (ISSN-L)
OpenAlex
W2336178299
Cited by
225
References
31
FWCI
17.16
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.