Blood Pressure Measurement: Retrospective and Prospective Views
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Measurement of the arterial blood pressure (BP) is a time-honored, vital piece of medical information whose accuracy is seldom questioned. This review identifies the unappreciated weakness of the early validation data that compared the cuff to intra-arterial BP's. Unfortunately, the inaccuracy of the auscultatory systolic (SBP) and diastolic (DBP) measurements are necessarily transmitted to the arithmetically calculated mean (MBP) and pulse pressures (PP). The errors in cuff SBP have limited recent efforts to measure central SBP noninvasively because of the need for cuff pressure calibration of the recorded peripheral pulses. Furthermore, cuff DBP's routinely overestimate intra-arterial values adding to the error in the calculation of central PP-a recognized cardiovascular risk predictor.Validation data for the newer automatic oscillometric SBP and DBP measurements are little better. Oscillometric devices, however, offer some improvement in their recognition of the MBP, a measurement made independently of the SBP and DBP. The algorithms used to identify the SBP and DBP by the oscillometric device manufacturers are proprietary and differ from one another. Thus, the accuracy of the commercial devices cannot be compared or standardized. A data base listing those devices that have been "validated" against the inaccurate auscultatory method is available, but many commercial devices are not listed.In addition to the SBP and DBP, there is increasing interest in the information contained within the arterial and aortic pulses. Values such as pulse augmentation and amplification ratios are independent of calibration requirements and add risk assessment information beyond that of the BP itself.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Burt, V. L., Whelton, P., Roccella, E. J., Brown, C., Cutler, J. A., Higgins, M., Horan, M. J., & Labarthe, D. (1995) · Hypertension · doi:10.1161/01.hyp.25.3.305 · Cited by 2,998
Hemodynamic Patterns of Age-Related Changes in Blood Pressure: The Framingham Heart Study
Franklin, S. S., Gustin, W., Wong, N. D., Larson, M. G., Weber, M. A., Kannel, W. B., & Levy, D. (1997) · Circulation · doi:10.1161/01.cir.96.1.308 · Cited by 2,321
Franklin, S. S., Larson, M. G., Khan, S. A., Wong, N. D., Leip, E. P., Kannel, W. B., & Levy, D. (2001) · Circulation · doi:10.1161/01.cir.103.9.1245 · Cited by 1,390
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Cited by
Flynn, J. T., Daniels, S. R., Hayman, L. L., Maahs, D. M., McCrindle, B. W., Mitsnefes, M., Zachariah, J. P., & Urbina, E. M. (2014) · Hypertension · doi:10.1161/hyp.0000000000000007 · Cited by 594
Human Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
“The systole cycle is indicated by the The systole cycle is indicated by the time taken by the heart to leave S1 and arrive at S2, while the diastole is the duration between S2 and S1. time taken by the heart to leave S1 and arrive at S2, while the diastole is the duration between S2 and S1.”
Grimaldi, D., Carter, J. R., Van Cauter, E., & Leproult, R. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06847 · Cited by 153
“Mean arterial pressure was estimated using the standard calculation of one third pulse pressure plus diastolic pressure.(15)”
Cheng, H.-M., Chuang, S.-Y., Sung, S.-H., Yu, W.-C., Pearson, A., Lakatta, E. G., Pan, W.-H., & Chen, C.-H. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.06.029 · Cited by 148
Armstrong, M. K., Schultz, M. G., Picone, D. S., Black, J. A., Dwyer, N., Roberts-Thomson, P., & Sharman, J. E. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12674 · Cited by 59
Metadata
- Authors
- Smulyan, H., & Safar, M. E.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-06-01
- Volume
- 24
- Issue
- 6
- Pages
- 628-634
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2333733804
- Cited by
- 102
- References
- 7
- FWCI
- 6.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.