Assessment of the Diurnal Blood Pressure Profile and Detection of Non-Dippers Based on Home or Ambulatory Monitoring
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A unique advantage of ambulatory blood pressure (ABP) monitoring is the assessment of nocturnal blood pressure (BP) and the detection of non-dippers. This study assessed nocturnal BP and non-dippers using a novel home BP (HBP) monitor. METHODS: Eighty-one hypertensives performed within 2 weeks ABP (24-h, Microlife WatchBP O3) and HBP monitoring (Microlife WatchBPN) during daytime (6 days, duplicate morning and evening measurements) and nighttime (automated asleep measurements, 3 nights, 3 readings/night). Patients' preference in using ABP or HBP was assessed by a questionnaire. RESULTS: Strong associations were found between ABP and HBP (intraclass correlation coefficients for awake systolic/diastolic 0.75/0.81; asleep 0.87/0.85). No statistically significant difference was found between HBP and ABP (mean difference ± SD awake systolic/diastolic 1.5 ± 10.1/-1.1 ± 6.0 mm Hg, P = 0.20/0.09; asleep -0.4 ± 7.8/-1.0 ± 5.3, P = 0.63/0.09). There was substantial agreement (74%, kappa 0.2) between ABP and HBP in the detection of non-dippers, which was similar to the previously reported test-retest reproducibility of repeated ABP monitoring in the diagnosis of non-dippers. Moderate to severe disturbance from ABP monitoring was reported by 18% of the participants and severe restriction of their daily activities by 9, vs. 3 and 1.5%, respectively for HBP (P < 0.001/ <0.01, for comparisons respectively). Nighttime BP monitoring and cuff discomfort were the main complaints for ABP (46 and 32%, respectively) and HBP (34 and 28%), whereas 89% reported more nighttime sleep disturbance by ABP than HBP (P < 0.001). CONCLUSIONS: HBP monitoring appears to be a reliable and well accepted by users alternative to ABP for the assessment of nocturnal BP and the detection of non-dippers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The kappa statistic in reliability studies: use, interpretation, and sample size requirements
Sim, J., & Wright, C. C. (2005) · Physical Therapy · doi:10.1093/ptj/85.3.257 · Cited by 4,093
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationFagard, R. H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.9 · Cited by 324
Home Blood Pressure as a Cardiovascular Outcome Predictor: It’s Time to Take This Method Seriously
Stergiou, G. S., Siontis, K. C. M., & Ioannidis, J. P. A. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.150771 · Cited by 84
Self-citationSelf blood pressure monitoring: a worthy substitute for ambulatory blood pressure?
McGowan, N., & Padfield, P. L. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.15 · Cited by 31
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“similar to those obtained by ABPM.(170) Some studies have shown that the use of HBPM is associated with a reduction in clinical/therapeutic inertia.”
ResultInfluentialNocturnal Hypertension: New Technology and Evidence
Kario, K. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.10971 · Cited by 298
Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application
Asayama, K., Fujiwara, T., Hoshide, S., Ohkubo, T., Kario, K., Stergiou, G. S., Parati, G., White, W. B., Weber, M. A., & Imai, Y. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000001987 · Cited by 120
Self-citationKollias, A., Ntineri, A., & Stergiou, G. S. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001189 · Cited by 90
“Patient’s preference Three studies used questionnaires to assess the patients’ acceptability of home and ambulatory night-time BP monitoring [13,15,22].”
BackgroundMethodResultInfluentialSelf-citationEmergence of Home Blood Pressure-Guided Management of Hypertension Based on Global Evidence
Kario, K., Shimbo, D., Hoshide, S., Wang, J.-G., Asayama, K., Ohkubo, T., Imai, Y., McManus, R. J., Kollias, A., Niiranen, T. J., et al. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12630 · Cited by 82
Self-citation
Metadata
- Authors
- Stergiou, G. S., Nasothimiou, E. G., Destounis, A., Poulidakis, E., Evagelou, I., & Tzamouranis, D.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-06-14
- Volume
- 25
- Issue
- 9
- Pages
- 974-978
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W1990175657
- Cited by
- 54
- References
- 6
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.