Cited by 38Non-Invasive Vital Sign MonitoringAnalytical Chemistry and SensorsOptical Imaging and Spectroscopy Techniques

Skin colour affects the accuracy of medical oxygen sensors

Open access
Keller, Matthew D., Harrison-Smith, Brandon, Patil, Chetan, Arefin, Mohammed Shahriar·2022·Nature

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/d41586-022-03161-1

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Overestimated SpO2 readings in patients with darker skin pigmentation lead to lower hospital admission, higher occult hypoxemia, delayed or no access to dexamethasone, therapeutic oxygen, and COVID-19 therapies, resulting in increased hospital readmission, organ dysfunction, and mortality.

    “leading to lower hospital admission; higher occult hypoxemia; and delayed or no access to dexamethasone, therapeutic oxygen, and COVID-19 therapies, resulting in increased hospital readmission, organ dysfunction, and mortality [11-18].”

    From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [18]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • Patients with darker skin pigmentation are more likely than patients with lighter skin color to have overestimated SpO2 readings.

    “Patients with darker skin pigmentation are more likely than patients with lighter skin color to have overestimated SpO2 readings”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 7

  1. Valbuena, V. S. M. et al. BMJ 378, e069775 (2022).
  2. Wong, A.-K. I. et al. JAMA Netw. Open 4, e2131674 (2021).
  3. Jacques, S. L. Phys. Med. Biol. 58, R37 (2013).
  4. Chatterjee, S. & Kyriacou, P. A. Sensors 19, 789 (2019).
  5. Boonya-ananta, T. et al. Sci. Rep. 11, 2570 (2021).
  6. Arefin, M. S., Dumont, A. P. & Patil, C. A. Proc. SPIE 11951, 1195103 (2022).
  7. Fine, J. et al. Biosensors 11, 126 (2021).

Cited by

Sorted by citations

Authors
Keller, M. D., Harrison-Smith, B., Patil, C., & Arefin, M. S.
Affiliations
  • Purdue University West Lafayette (US)
  • Temple University (US)
Corresponding author
  • Keller, Matthew D.
  • Harrison-Smith, Brandon
  • Patil, Chetan
  • Arefin, Mohammed Shahriar
Venue
Nature
Published
2022-10-19
Volume
610
Issue
7932
Pages
449-451
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W4306844729
Cited by
38
References
9
Citations by year
2026: 2 · 2025: 14 · 2024: 11 · 2023: 11
FWCI
2.62
Type
journal article
Language
en
Open access
Locations
  • Nature (publishedVersion)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
skin pigmentation, pulse oximetry, oxygen saturation, dark skin, measurement accuracy, COVID-19 pandemic, skin colour
MeSH terms
Humans, Oximetry, Oxygen, Skin Pigmentation, Reproducibility of Results, Artifacts

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review