The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
What makes a BIA equation unique? Validity of eight-electrode multifrequency BIA to estimate body composition in a healthy adult population
Abstract
Background/objectives The validity of bioelectrical impedance analysis (BIA) for body composition analysis is limited by assumptions relating to body shape. Improvement in BIA technology could overcome these limitations and reduce the population specificity of the BIA algorithm. Subjects/methods BIA equations for the prediction of fat-free mass (FFM), total body water (TBW) and extracellular water (ECW) were generated from data obtained on 124 Caucasians (body mass index 18.5-35 kg/m(2)) using a four-compartment model and dilution techniques as references. The algorithms were validated in an independent multiethnic population (n=130). The validity of BIA results was compared (i) between ethnic groups and (ii) with results from the four-compartment model and two-compartment methods (air-displacement plethysmography, dual-energy X-ray absorptiometry and deuterium dilution). Results Indices were developed from segmental R and Xc values to represent the relative contribution of trunk and limbs to total body conductivity. The coefficient of determination for all prediction equations was high (R(2): 0.94 for ECW, 0.98 for FFM and 0.98 for TBW) and root mean square error was low (1.9 kg for FFM, 0.8 l for ECW and 1.3 kg for TBW). The bias between BIA results and different reference methods was not statistically different between Afro-American, Hispanic, Asian or Caucasian populations and showed a similar difference (-0.2-0.2 kg FFM) when compared with the bias between different two-compartment reference methods (-0.2-0.3 kg FFM). Conclusions An eight-electrode, segmental multifrequency BIA is a valid tool to estimate body composition in healthy euvolemic adults compared with the validity and precision of other two-compartment reference methods. Population specificity is of minor importance when compared with discrepancies between different reference methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917
Body composition from fluid spaces and density: analysis of methods. 1961.
Siri, W. E. (1994) · PubMed · Cited by 2,556
Techniques for Measuring Body Composition
National Research Council (1961) · National Academies Press eBooks · doi:10.17226/21603 · Cited by 1,620
Pace, N., & Rathbun, E. N. (1945) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)51345-x · Cited by 757
Sun, S. S., Chumlea, W. C., Heymsfield, S. B., Lukaski, H. C., Schoeller, D., Friedl, K., Kuczmarski, R. J., Flegal, K. M., Johnson, C. L., & Hubbard, V. S. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.2.331 · Cited by 692
Is bioelectrical impedance accurate for use in large epidemiological studies?
Dehghan, M., & Merchant, A. T. (2008) · Nutrition Journal · doi:10.1186/1475-2891-7-26 · Cited by 506
Whole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429
The genetic contribution to non-syndromic human obesity
Walley, A. J., Asher, J. E., & Froguel, P. (2009) · Nature Reviews Genetics · doi:10.1038/nrg2594 · Cited by 412
Measures of body composition in blacks and whites: a comparative review
Wagner, D. R., & Heyward, V. H. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/71.6.1392 · Cited by 397
Fuller, N. J., Jebb, S. A., Laskey, M. A., Coward, W. A., & Elia, M. (1992) · Clinical Science · doi:10.1042/cs0820687 · Cited by 394
Why bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361
Segmental bioelectrical impedance analysis: theory and application of a new technique
Organ, L. W., Bradham, G. B., Gore, D. T., & Lozier, S. L. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.1.98 · Cited by 274
Pace, N., Kline, L., Schachman, H. K., & Harfenist, M. (1947) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)30906-7 · Cited by 238
The Validity of Bioelectrical Impedance Models in Clinical Populations
Buchholz, A. C., Bartok, C., & Schoeller, D. A. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019005433 · Cited by 231
Shafer, K. J., Siders, W. A., Johnson, L. K., & Lukaski, H. C. (2008) · Nutrition · doi:10.1016/j.nut.2008.07.004 · Cited by 223
(1989) · PubMed · Cited by 156
Indirect estimates of body composition are useful for groups but unreliable in individuals
Piers, L., Soares, M. J., Frandsen, S., & O’Dea, K. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801387 · Cited by 134
Korth, O., Bosy‐Westphal, A., Zschoche, P., Glüer, C.-C., Heller, M., & Müller, M. J. (2006) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602556 · Cited by 109
Self-citationDey, D. K., Bosaeus, I., Lissner, L., & Steen, B. (2003) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601625 · Cited by 75
Advances in the Science and Application of Body Composition Measurement
Baracos, V. E., Caserotti, P., Earthman, C. P., Fields, D. A., Gallagher, D., Hall, K. D., Heymsfield, S. B., Müller, M. J., Rosen, A. N., Pichard, C., et al. (2012) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607111417448 · Cited by 75
Self-citationGenetic studies of common types of obesity: a critique of the current use of phenotypes
Müller, M. J., Bosy‐Westphal, A., & Krawczak, M. (2010) · Obesity Reviews · doi:10.1111/j.1467-789x.2010.00734.x · Cited by 57
Self-citationAlemán-Mateo, H., Rush, E. C., Esparza‐Romero, J., Ferriolli, E., Ramírez‐Zea, M., Bour, A., Yuchingtat, G., Ndour, R., Mokhtar, N., Valencia, M. E., et al. (2010) · The journal of nutrition health & aging · doi:10.1007/s12603-010-0031-z · Cited by 33
Montagnese, C., Williams, J. E., Haroun, D., Siervo, M., Fewtrell, M. S., & Wells, J. C. K. (2012) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2011.213 · Cited by 30
Water homeostasis, frailty and cognitive function in the nursing home
Kehayias, J. J., Ribeiro, S. M. L., Skahan, A., et al. (2011) · The journal of nutrition health & aging · doi:10.1007/s12603-011-0079-4 · Cited by 27
Self-citationDiouf, A., Gartner, A., Dossou, N. I., Sanon, D., Bluck, L. J. C., Wright, A., & Wade, S. (2008) · British Journal Of Nutrition · doi:10.1017/s0007114508067640 · Cited by 10
Flagged first, then by citations
Cited by
Sorted by citations
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 410
International society of sports nutrition position stand: diets and body composition
Aragon, A. A., Schoenfeld, B. J., Wildman, R., Kleiner, S., VanDusseldorp, T., Taylor, L., Earnest, C. P., Arciero, P. J., Wilborn, C., Kalman, D. S., et al. (2017) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-017-0174-y · Cited by 301
Müller, M. J., Enderle, J., Pourhassan, M., Braun, W., Eggeling, B., Lagerpusch, M., Glüer, C.-C., Kehayias, J. J., Kiosz, D., & Bosy-Westphal, A. (2015) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.109173 · Cited by 254
Self-citationBody Composition Tools for Assessment of Adult Malnutrition at the Bedside
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 246
Bosy-Westphal, A., Jensen, B., Braun, W., Pourhassan, M., Gallagher, D., & Müller, M. J. (2017) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2017.27 · Cited by 231
Self-citation
Metadata
- Authors
- Bosy-Westphal, A., Schautz, B., Later, W., Kehayias, J. J., Gallagher, D., & Müller, M. J.
- Affiliations
- Christian-Albrechts-Universität zu Kiel (DE)
- Tufts University (US)
- St. Luke's-Roosevelt Hospital Center (US)
- Venue
- European Journal of Clinical Nutrition
- Published
- 2013-01
- Volume
- 67
- Issue
- S1
- Pages
- S14-S21
- ISSN
- 0954-3007 (ISSN-L)
- 1476-5640
- OpenAlex
- W2018773294
- Cited by
- 296
- References
- 26
- Citations by year
- 2026: 22 · 2025: 36 · 2024: 21 · 2023: 34 · 2022: 40 · 2021: 34 · 2020: 28 · 2019: 23 · 2018: 18 · 2017: 13 · 2016: 6 · 2015: 6 · 2014: 9 · 2013: 6
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Journal of Clinical Nutrition (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK026687)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- bioelectrical impedance analysis, body composition, fat-free mass, total body water, extracellular water, ethnic differences, population specificity, four-compartment model, air displacement plethysmography, dual-energy X-ray absorptiometry, deuterium dilution, healthy adults
- MeSH terms
- Adipose Tissue, Adult, Algorithms, Anthropometry, Black or African American, Body Composition, Body Fluid Compartments, Electrodes, Female, Hispanic or Latino, Humans, Indicator Dilution Techniques, Male, Middle Aged, Plethysmography, Reproducibility of Results, Absorptiometry, Photon, Electric Impedance, Asian People
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review