Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 1,479

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Graphical Analysis of Reversible Radioligand Binding from Time—Activity Measurements Applied to [N-11C-Methyl]-(−)-Cocaine PET Studies in Human Subjects

Logan, Jean, Fowler, Joanna S., Volkow, Nora D., Wolf, Alfred P., Dewey, Stephen L., Schlyer, David J., MacGregor, Robert R., Hitzemann, Robert, Bendriem, Bernard, Gatley, S. John, Christman, David R. · 1990 · Journal of Cerebral Blood Flow & Metabolism

Abstract

A graphical method of analysis applicable to ligands that bind reversibly to receptors or enzymes requiring the simultaneous measurement of plasma and tissue radioactivities for multiple times after the injection of a radiolabeled tracer is presented. It is shown that there is a time t† after which a plot of f t0 ROI( t') dt'/ROI( t) versus f t0 C p( t') dt'/ROI( t) (where ROI and C p are functions of time describing the variation of tissue radioactivity and plasma radioactivity, respectively) is linear with a slope that corresponds to the steady-state space of the ligand plus the plasma volume, V p. For a two-compartment model, the slope is given by λ + V p, where λ is the partition coefficient and the intercept is −1/[ k 2(1 + V p/λ)]. For a three-compartment model, the slope is λ(1 + B max/ K d) + V p and the intercept is −{(1 + B max/ K d)/ k 2 + [ k off(1 + K d/ B max)]−1} [1 + V p/λ(1 + B max/ K d)]−1 (where B max represents the concentration of ligand binding sites and K d the equilibrium dissociation constant of the ligand–binding site complex, k off ( k 4) the ligand–binding site dissociation constant, and k 2 is the transfer constant from tissue to plasma). This graphical method provides the ratio B max/ K d from the slope for comparison with in vitro measures of the same parameter. It also provides an easy, rapid method for comparison of the reproducibility of repeated measures in a single subject, for longitudinal or drug intervention protocols, or for comparing experimental results between subjects. Although the linearity of this plot holds when ROI/ C p is constant, it can be shown that, for many systems, linearity is effectively reached some time before this. This analysis has been applied to data from [ N-methyl-11 C]-(–)-cocaine ([11 C]cocaine) studies in normal human volunteers and the results are compared to the standard nonlinear least-squares analysis. The calculated value of B max/ K d for the high-affinity binding site for cocaine is 0.62 ± 0.20, in agreement with literature values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1990.127

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Research works printed but not linked: 3

  1. Carson RE, 1986, Positron Emission Tomography and Autoradiography: Principles and Applications for the Brain and Heart, 347
  2. Logan J, 1989, J Nucl Med, 30, 898
  3. Phelps ME, 1979, J Nucl Med, 20, 328

Cited by

Items 101–123 of 123

Metadata

Authors
Logan, J., Fowler, J. S., Volkow, N. D., Wolf, A. P., Dewey, S. L., Schlyer, D. J., MacGregor, R. R., Hitzemann, R., Bendriem, B., Gatley, S. J., & Christman, D. R.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1990-09
Volume
10
Issue
5
Pages
740-747
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2063017390
Cited by
1,479
References
14
FWCI
6.42
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.