The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Integrating MEMS and ICs
Open accessAbstract
The majority of microelectromechanical system (MEMS) devices must be combined with integrated circuits (ICs) for operation in larger electronic systems. While MEMS transducers sense or control physical, optical or chemical quantities, ICs typically provide functionalities related to the signals of these transducers, such as analog-to-digital conversion, amplification, filtering and information processing as well as communication between the MEMS transducer and the outside world. Thus, the vast majority of commercial MEMS products, such as accelerometers, gyroscopes and micro-mirror arrays, are integrated and packaged together with ICs. There are a variety of possible methods of integrating and packaging MEMS and IC components, and the technology of choice strongly depends on the device, the field of application and the commercial requirements. In this review paper, traditional as well as innovative and emerging approaches to MEMS and IC integration are reviewed. These include approaches based on the hybrid integration of multiple chips (multi-chip solutions) as well as system-on-chip solutions based on wafer-level monolithic integration and heterogeneous integration techniques. These are important technological building blocks for the ‘More-Than-Moore’ paradigm described in the International Technology Roadmap for Semiconductors. In this paper, the various approaches are categorized in a coherent manner, their merits are discussed, and suitable application areas and implementations are critically investigated. The implications of the different MEMS and IC integration approaches for packaging, testing and final system costs are reviewed. Combining micrometer-sized movable components and electronic devices adds functionality to integrated circuits. Microelectromechanical systems (MEMS) are flexible transducers that can measure acceleration or the presence of chemicals, to give just two examples. Andreas C. Fischer and colleagues from the KTH Royal Institute of Technology in Sweden review both traditional and emerging approaches forplacing MEMS on the same platform as the electronics needed to process the electrical signals they produce, thus producing smaller and cheaper components. Such approaches include creating the MEMS and electronics on separate substrates and then combining them, or developing fabrication processes that are able to define both types of device on the same substrate. The researchers conclude that the most cost-effective solution depends on the specific application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Microfabrication
(2016) · Micromechatronics · doi:10.1201/b15830-17 · Cited by 2,109
Fundamentals of Microsystems Packaging
Tummala, R. (2001) · Cited by 989
Transfer Printing Techniques for Materials Assembly and Micro/Nanodevice Fabrication
Carlson, A., Bowen, A. M., Huang, Y., Nuzzo, R. G., & Rogers, J. A. (2012) · Advanced Materials · doi:10.1002/adma.201201386 · Cited by 917
Demystifying 3D ICs: The Pros and Cons of Going Vertical
Davis, W. R., Wilson, J., Mick, S., Xu, J., Hua, H., Mineo, C., Sule, A. M., Steer, M., & Franzon, P. D. (2005) · IEEE Design and Test of Computers · doi:10.1109/mdt.2005.136 · Cited by 836
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
A MEMS-based projection display
Van Kessel, P. F., Hornbeck, L. J., Meier, R. E., & Douglass, M. R. (1998) · Proceedings of the IEEE · doi:10.1109/5.704274 · Cited by 612
Layer-by-Layer Assembly of Nanowires for Three-Dimensional, Multifunctional Electronics
Javey, A., Nam, Friedman, R. S., Yan, H., & Lieber, C. M. (2007) · Nano Letters · doi:10.1021/nl063056l · Cited by 597
Niklaus, F., Stemme, G., Lu, J. Q., & Gutmann, R. J. (2006) · Journal of Applied Physics · doi:10.1063/1.2168512 · Cited by 472
Self-citationElectromechanical Piezoresistive Sensing in Suspended Graphene Membranes
Smith, A. D., Niklaus, F., Paussa, A., Vaziri, S., Fischer, A. C., Sterner, M., Forsberg, F., Delin, A., Esseni, D., Palestri, P., et al. (2013) · Nano Letters · doi:10.1021/nl401352k · Cited by 413
Self-citationEsashi, M. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/7/073001 · Cited by 358
MEMS-based uncooled infrared bolometer arrays: a review
Niklaus, F., Vieider, C., & Jakobsen, H. (2007) · SPIE Proceedings · doi:10.1117/12.755128 · Cited by 310
Self-citationTummala, R. R. (2004) · IEEE Transactions on Advanced Packaging · doi:10.1109/tadvp.2004.830354 · Cited by 274
Self-assembly from milli- to nanoscales: methods and applications
Mastrangeli, M., Abbasi, S., Varel, C., Van Hoof, C., Celis, J.-P., & Böhringer, K. F. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/8/083001 · Cited by 256
An Integrated Force-balanced Capacitive Accelerometer For Low-G Applications
Chau, K. H.-L., Lewis, S. R., Zhao, Y., Howe, R. T., Bart, S. F., & Marcheselli, R. G. (2005) · Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95 · doi:10.1109/sensor.1995.717294 · Cited by 189
An implantable CMOS circuit interface for multiplexed microelectrode recording arrays
Ji, J., & Wise, K. D. (1992) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.121568 · Cited by 173
Post-CMOS processing for high-aspect-ratio integrated silicon microstructures
Xie, H., Erdmann, L., Zhu, X., Gabriel, K. J., & Fedder, G. K. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/84.993443 · Cited by 167
Wafer-Level Heterogeneous Integration for MOEMS, MEMS, and NEMS
Lapisa, M., Stemme, G., & Niklaus, F. (2011) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2010.2093570 · Cited by 157
Self-citationEmbedded micromechanical devices for the monolithic integration of MEMS and CMOS
Sandia National Labs., A., Smith, J., USDOE, W., et al. (1995) · doi:10.2172/114489 · Cited by 151
An integrated mass flow sensor with on-chip CMOS interface circuitry
Yoon, E., & Wise, K. D. (1992) · IEEE Transactions on Electron Devices · doi:10.1109/16.137317 · Cited by 136
Fabrication, characterization, and analysis of a DRIE CMOS-MEMS gyroscope
Xie, H., & Fedder, G. K. (2003) · IEEE Sensors Journal · doi:10.1109/jsen.2003.817901 · Cited by 117
CMOS-MEMS membrane for audio-frequency acoustic actuation
Neumann, J. J., & Gabriel, K. J. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00728-2 · Cited by 109
Toward Waveform Nonlinear Optics Using Multimillijoule Sub-Cycle Waveform Synthesizers
Mücke, O. D., Fang, S., Cirmi, G., Rossi, G. M., Chia, S., Ye, H., Yang, Y., Mainz, R. E., Manzoni, C., Farinello, P., et al. (2015) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2015.2426653 · Cited by 108
Development of a miniature pressure transducer for biomedical applications
Ko, W. H., Hynecek, J., & Boettcher, S. F. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19793 · Cited by 108
Microsensor Integration Into Systems-on-Chip
Brand, O. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.873618 · Cited by 106
Kazior, T. E. (2014) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2013.0105 · Cited by 104
Embedded micromechanical devices for the monolithic integration of MEMS with CMOS
Smith, J. H., Montague, S., Sniegowski, J. J., et al. (2002) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.1995.499295 · Cited by 97
Integrated signal conditioning for silicon pressure sensors
Borky, J. M., & Wise, K. D. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19794 · Cited by 92
Pressure sensors based on suspended graphene membranes
Smith, A. D., Vaziri, S., Niklaus, F., Fischer, A. C., Sterner, M., Delin, A., Östling, M., & Lemme, M. C. (2013) · Solid-State Electronics · doi:10.1016/j.sse.2013.04.019 · Cited by 85
Self-citationA Fully Integrated Multisite Pressure Sensor for Wireless Arterial Flow Characterization
DEHENNIS, A. D., & Wise, K. D. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.876668 · Cited by 65
An industrial CMOS process family adapted for the fabrication of smart silicon sensors
Müller, T., Brandl, M., Brand, O., et al. (2000) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(99)00348-9 · Cited by 54
Forsberg, F., Lapadatu, A. C., Kittilsland, G., Martinsen, S., Roxhed, N., Fischer, A. C., Stemme, G., Samel, B., Ericsson, P., Høivik, N., et al. (2014) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2014.2358198 · Cited by 44
Self-citationFull integration of a pressure-sensor system into a standard BiCMOS process
Scheiter, T., Kapels, H., Oppermann, K.-G., et al. (1998) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(98)00029-6 · Cited by 41
A merged MEMS-CMOS process using silicon wafer bonding
Parameswaran, L., Hsu, C.-M., & Schmidt, M. A. (2002) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.1995.499296 · Cited by 40
A modular process for integrating thick polysilicon MEMS devices with sub-micron CMOS
Yasaitis, J. A., Judy, M. W., Brosnihan, T., et al. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.478294 · Cited by 37
Integrating microelectromechanical systems with integrated circuits
Bryzek, J., Flannery, A. F., & Skurnik, D. (2004) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2004.1304566 · Cited by 35
Brosnihan, T., Brown, S. A., Brogan, A., et al. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1217096 · Cited by 31
A wideband monolithic RMS-DC converter using micromachined diaphragm structures
Yoon, E., & Wise, K. D. (1994) · IEEE Transactions on Electron Devices · doi:10.1109/16.310122 · Cited by 30
Electrochemical etch stop engineering for bulk micromachining
Ashruf, C. M. A., French, P. J., Sarro, P. M., et al. (1998) · Mechatronics · doi:10.1016/s0957-4158(98)00017-8 · Cited by 28
Wafer-level packaging technology for MEMS
Mirza, A. R. (2002) · I-THERM :/I-THERM - Intersociety Conference on Thermal Phenomena in Electronic Systems · doi:10.1109/itherm.2000.866816 · Cited by 28
Forsberg, F., Roxhed, N., Fischer, A. C., Samel, B., Ericsson, P., Høivik, N., Lapadatu, A. C., Bring, M., Kittilsland, G., Stemme, G., et al. (2013) · Infrared Physics & Technology · doi:10.1016/j.infrared.2013.05.006 · Cited by 26
Self-citationA Bulk-micromachined 1024-element Uncooled Infrared Imager
Oliver, A. D., Baer, W. G., & Wise, K. D. (2005) · Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95 · doi:10.1109/sensor.1995.721912 · Cited by 25
Heterogeneous integration by adhesive bonding
Esashi, M., & Tanaka, S. (2013) · Micro and Nano Systems Letters · doi:10.1186/2213-9621-1-3 · Cited by 21
Esashi, E. (2009) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2009.5285574 · Cited by 16
Modular integration of CMOS and SOI-MEMS using "plug-up" concept
Kiihamäki, J., Ronkainen, H., Pekko, P., et al. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1217098 · Cited by 11
Low-temperature Al–Ge bonding for 3D integration
Crnogorac, F., Pease, F. W., Birringer, R. P., & Dauskardt, R. H. (2012) · Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena · doi:10.1116/1.4762844 · Cited by 11
Wafer-level heterogeneous 3D integration for MEMS and NEMS
Niklaus, F., Lapisa, M., Bleiker, S. J., Dubois, V., Roxhed, N., Fischer, A. C., Forsberg, F., Stemme, G., Grogg, D., & Despont, M. (2012) · International Workshop on Low Temperature Bonding for 3D Integration (LTB-3D) · doi:10.1109/ltb-3d.2012.6238096 · Cited by 9
Self-citationEsashi, M., & Tanaka, S. (2012) · Advances in science and technology · doi:10.4028/www.scientific.net/ast.81.55 · Cited by 5
Cited by
The hot pick-up technique for batch assembly of van der Waals heterostructures
Pizzocchero, F., Gammelgaard, L., Jessen, B. S., Caridad, J. M., Wang, L., Hone, J., Bøggild, P., & Booth, T. J. (2016) · Nature Communications · doi:10.1038/ncomms11894 · Cited by 709
Resistive graphene humidity sensors with rapid and direct electrical readout
Smith, A. D., Elgammal, K., Niklaus, F., Delin, A., Fischer, A. C., Vaziri, S., Forsberg, F., Råsander, M., Hugosson, H., Bergqvist, L., et al. (2015) · Nanoscale · doi:10.1039/c5nr06038a · Cited by 330
Self-citationThakur, N., Thakur, N., Kumar, A., Thakur, V. K., Kalia, S., Arya, V., Kumar, A., Kumar, S., & Kyzas, G. Z. (2024) · Science of The Total Environment · doi:10.1016/j.scitotenv.2023.169815 · Cited by 272
RetractedCarratù, M., Gallo, V., Dello Iacono, S., Sommella, P., Ciani, L., & Patrizi, G. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3502814 · Cited by 14
Metadata
- Authors
- Fischer, A. C., Forsberg, F., Lapisa, M., Bleiker, S. J., Stemme, G., Roxhed, N., & Niklaus, F.
- Venue
- Microsystems & Nanoengineering
- Published
- 2015-05-28
- Volume
- 1
- Issue
- 1
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W3103527158
- Cited by
- 363
- References
- 47
- FWCI
- 17.16
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.