The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces
Open accessAbstract
Implantable neural microelectrodes that can record extracellular biopotentials from small, targeted groups of neurons are critical for neuroscience research and emerging clinical applications including brain-controlled prosthetic devices. The crucial material-dependent problem is developing microelectrodes that record neural activity from the same neurons for years with high fidelity and reliability. Here, we report the development of an integrated composite electrode consisting of a carbon-fibre core, a poly(p-xylylene)-based thin-film coating that acts as a dielectric barrier and that is functionalized to control intrinsic biological processes, and a poly(thiophene)-based recording pad. The resulting implants are an order of magnitude smaller than traditional recording electrodes, and more mechanically compliant with brain tissue. They were found to elicit much reduced chronic reactive tissue responses and enabled single-neuron recording in acute and early chronic experiments in rats. This technology, taking advantage of new composites, makes possible highly selective and stealthy neural interface devices towards realizing long-lasting implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The microscale geometries presented in (A-C) are each associated with an improved tissue response to the implant.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [71]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [312]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Coating the electrode site with poly(3,4-ethylenedioxythiphene) (PED-OT) facilitates signal detection.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [71]
The cited source says what the claim attributes to it.
In the citing paper
“Next-generation devices fabricated from parylene-insulated carbon fibers with antibiofouling poly(ethylene glycol) methacrylate coatings have demonstrated robust recording quality and a minimal accompanying tissue response (Fig. 3C).71”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [71]
The cited source says what the claim attributes to it.
In the citing paper
“While the smaller electrode sites necessitated by finer-scale geometries have the drawback of increased impedance, inclusion of conductive polymers mitigates this effect and allows improved signal detection.71,72”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [71]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
A controlled cortical impact model of traumatic brain injury in the rat
Edward Dixon, C., Clifton, G. L., Lighthall, J. W., Yaghmai, A. A., & Hayes, R. L. (1991) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(91)90104-8 · Cited by 1,141
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Unterberg, A. W., Stover, J., Kress, B., & Kiening, K. L. (2004) · Neuroscience · doi:10.1016/j.neuroscience.2004.06.046 · Cited by 881
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Self-citationLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citation
Cited by
Items 301–400 of 718
Research Progress on the Flexibility of an Implantable Neural Microelectrode
Zhao, H., Liu, R., Zhang, H., Cao, P., Liu, Z., & Li, Y. (2022) · Micromachines · doi:10.3390/mi13030386 · Cited by 41
“Kipke and co-workers [94] developed an ultra-small, implantable carbon fiber microelectrode with a cross-sectional diameter of only 8.”
BackgroundSelf-citationBasic concepts, advances and emerging applications of nanophotonics
Iqbal, M. A., Malik, M., Anwar, N., Bakhsh, S., Javeed, S., Maidin, S. S., Morsy, K., Capangpangan, R. Y., Alguno, A. C., & Choi, J. R. (2023) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2023.105040 · Cited by 38
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 44
“When electrodes are implanted near a major blood vessel without damaging it, astrocytes and microglia activity is still increased (Kozai et al. 2012b).”
InfluentialA biodegradable, flexible photonic patch for in vivo phototherapy
Deng, K., Tang, Y., Xiao, Y., Zhong, D., Zhang, H., Fang, W., Shen, L., Wang, Z., Pan, J., Lu, Y., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-38554-x · Cited by 48
Self-citationTang, C., Han, Z., Liu, Z., Li, W., Shen, J., Zhang, K., Mai, S., Li, J., Sun, X., Chen, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202407874 · Cited by 35
Wang, L., He, M., Gong, T., Zhang, X., Zhang, L., Liu, T., Ye, W., Pan, C., & Zhao, C. (2017) · Biomaterials Science · doi:10.1039/c7bm00673j · Cited by 35
Electrochemical detection of exogenously administered melatonin in the brain
Castagnola, E., Woeppel, K. M., Golabchi, A., McGuier, M., Chodapaneedi, N., Metro, J., Taylor, I. M., & Cui, X. T. (2020) · The Analyst · doi:10.1039/d0an00051e · Cited by 37
Three-dimensional fuzzy graphene ultra-microelectrodes for subcellular electrical recordings
Rastogi, S. K., Bliley, J. M., Matino, L., Garg, R., Santoro, F., Feinberg, A. W., & Cohen‐Karni, T. (2020) · Nano Research · doi:10.1007/s12274-020-2695-y · Cited by 36
Carbon Nanotube Fibers for Neural Recording and Stimulation
Alvarez, N. T., Buschbeck, E. K., Miller, S., Le, A. D., Gupta, V. K., Ruhunage, C. K., Vilinsky, I., & Ma, Y. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00861 · Cited by 39
Multifunctional Neural Interfaces for Closed‐Loop Control of Neural Activity
Chapman, C. A. R., Goshi, N., & Şeker, E. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703523 · Cited by 42
Underwater‐Transparent Nanodendritic Coatings for Directly Monitoring Cancer Cells
Gao, Y., Liu, H., Liu, X., Zhang, P., Huang, C., Xu, T., Jiang, L., & Wang, S. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300233 · Cited by 34
Vardi, R., Goldental, A., Sardi, S., Sheinin, A., & Kanter, I. (2016) · Scientific Reports · doi:10.1038/srep36228 · Cited by 34
All-Polymeric Electrode Based on PEDOT:PSS for In Vivo Neural Recording
Filho, G., Júnior, C. J. M., Spinelli, B. G., Damasceno, I. Z., Fiuza, F. P., & Morya, E. (2022) · Biosensors · doi:10.3390/bios12100853 · Cited by 35
Ghilane, J., Hauquier, F., & Lacroix, J. C. (2013) · Analytical Chemistry · doi:10.1021/ac402994u · Cited by 38
Development and Characterization of a Sucrose Microneedle Neural Electrode Delivery System
Apollo, N. V., Jiang, J. L., Cheung, W., Baquier, S. H., Lai, A., Mirebedini, A., Foroughi, J., Wallace, G. G., Shivdasani, M. N., Prawer, S., et al. (2017) · Advanced Biosystems · doi:10.1002/adbi.201700187 · Cited by 35
Microfabricated intracortical extracellular matrix-microelectrodes for improving neural interfaces
Shen, W., Das, S., Vitale, F., Richardson, A. G., Ananthakrishnan, A., Struzyna, L. A., Brown, D. P., Song, N., Ramkumar, M., Lucas, T. H., et al. (2018) · Microsystems & Nanoengineering · doi:10.1038/s41378-018-0030-5 · Cited by 38
A lightweight, wireless Bluetooth-low-energy neuronal recording system for mice
Idogawa, S., Yamashita, K., Sanda, R., Numano, R., Koida, K., & Kawano, T. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129423 · Cited by 37
Insertional effect following electrode implantation: an underreported but important phenomenon
Hamani, C., Davidson, B., Lipsman, N., Abrahão, A., Nestor, S. M., Rabin, J. S., Giacobbe, P., Pagano, R. L., & Campos, A. C. P. (2024) · Brain Communications · doi:10.1093/braincomms/fcae093 · Cited by 33
Magnetically Inserted Neural Electrodes: Tissue Response and Functional Lifetime
Dryg, I., Ward, M. P., Qing, K. Y., Mei, H., Schaffer, J. E., & Irazoqui, P. P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2399856 · Cited by 34
“size [16], [17], lower material stiffness [18]–[20], and lower material density [21] all seem to decrease damage caused by insertion or reduce the intensity of the tissue response.”
BackgroundDegradable, silyl ether thiol–ene networks
Ware, T. H., Jennings, A. R., Bassampour, Z. S., Simon, D., Son, D. Y., & Voit, W. (2014) · RSC Advances · doi:10.1039/c4ra06997h · Cited by 40
Gilmour, A. D., Woolley, A. J., Poole-Warren, L. A., Thomson, C. E., & Green, R. A. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.03.011 · Cited by 39
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 36
Huang, W., Lai, H., Kuo, L., Liao, C., Chang, P., Liu, T., Chen, S., & Chen, Y. (2015) · Advanced Materials · doi:10.1002/adma.201500136 · Cited by 33
Dynamic Poly(3,4‐ethylenedioxythiophene)s Integrate Low Impedance with Redox‐Switchable Biofunction
Lin, H., Zhu, B., Wu, Y., Sekine, J., Nakao, A., Luo, S., Yamashita, Y., & Yu, H. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201703890 · Cited by 32
Flexible Bioelectronic Devices Based on Micropatterned Monolithic Carbon Fiber Mats
Vomero, M., Gueli, C., Zucchini, E., Fadiga, L., Erhardt, J. B., Sharma, S., & Stieglitz, T. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900713 · Cited by 33
High‐density implantable neural electrodes and chips for massive neural recordings
Wang, L., Suo, Y., Wang, J., Wang, X., Xue, K., An, J., Sun, X., Chen, Q., Tang, X., Zhao, Y., et al. (2024) · Brain‐X · doi:10.1002/brx2.65 · Cited by 36
Rong, X., Xiao, S., Geng, W., Zhu, B., Mou, P., Ding, Z., Zhang, B., Fan, Y., Qiu, L., & Cheng, C. (2025) · Nature Communications · doi:10.1038/s41467-025-61377-x · Cited by 32
“14, 15).”
Hess‐Dunning, A., & Tyler, D. J. (2018) · Micromachines · doi:10.3390/mi9110583 · Cited by 32
Sridar, S., Churchward, M. A., Mushahwar, V. K., Todd, K. G., & Elias, A. L. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.07.026 · Cited by 32
Deku, F., Joshi‐Imre, A., Mërtiri, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0401809jes · Cited by 33
Bioinspired flexible electronics for seamless neural interfacing and chronic recording
Li, H., Wang, J., & Fang, Y. Z. (2020) · Nanoscale Advances · doi:10.1039/d0na00323a · Cited by 32
Arafat, M. A., Rubin, L. N., Jefferys, J. G. R., & Irazoqui, P. P. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2932032 · Cited by 32
“Thin and flexible electrodes result in much reduced scar formation [19], [20].”
BackgroundElectronic Drugs: Spatial and Temporal Medical Treatment of Human Diseases
Won, C., Kwon, C., Park, K., Seo, J., & Lee, T. (2021) · Advanced Materials · doi:10.1002/adma.202005930 · Cited by 32
Zou, Y., Wang, J., Guan, S., Zou, L., Gao, L., Li, H., Fang, Y. Z., & Wang, C. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113477 · Cited by 30
Bioactive polymer-enabled conformal neural interface and its application strategies
Hu, Z., Niu, Q., Hsiao, B. S., Yao, X., & Zhang, Y. (2022) · Materials Horizons · doi:10.1039/d2mh01125e · Cited by 30
NeuroRoots, a bio-inspired, seamless Brain Machine Interface device for long-term recordingPreprint
Ferro, M. D., Proctor, C. M., Gonzalez, A., Zhao, E. T., Slézia, A., Pas, J., Dijk, G., Donahue, M. J., Williamson, A., Malliaras, G. G., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/460949 · Cited by 32
“Instead, we developed an electrode self-assembly method using capillarity to organize large arrays of NeuroRoots onto a microwire as small as 20μm in diameter, which in turn provides mechanical support to allow implantation, yet with minimal damage (25, 26).”
MethodNano functional neural interfaces
Wang, Y., Zhu, H., Yang, H., Argall, A. D., Luan, L., Xie, C., & Guo, L. (2018) · Nano Research · doi:10.1007/s12274-018-2127-4 · Cited by 31
Stocking, K. C., Vazquez, A. L., & Kozai, T. D. Y. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2889832 · Cited by 32
“cal stimulation [31], [44].”
Self-citationWang, K., Tang, R., Xiao-bo, Z., Li, J., Lang, Y., Jiang, X., Sun, H., Lin, Q., & Wang, C. (2015) · Nanoscale · doi:10.1039/c5nr05784a · Cited by 30
Orthogonal surface functionalization through bioactive vapor‐based polymer coatings
Deng, X., & Lahann, J. (2014) · Journal of Applied Polymer Science · doi:10.1002/app.40315 · Cited by 31
Self-citationZhao, Z., Gong, R., Zheng, L., & Wang, J. (2016) · Sensors · doi:10.3390/s16111851 · Cited by 32
Obaid, A., Wu, Y., Hanna, M., Nix, W. D., Ding, J., & Melosh, N. A. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/454520 · Cited by 31
Ghazavi, A., Maeng, J., Black, M., Salvi, S., & Cogan, S. F. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab52ab · Cited by 36
“…electrodes have been employed for recording neural activity in vitro (Sekirnjak et al 2006, Yu et al 2012) and in vivo (Schmidt et al 1976, Kozai et al 2012, Deku et al 2018, Gillis et al 2018), and for neural stimulation in vitro (Grumet et al 2000, Stett et al 2000, Jensen et al 2003,…”
MethodMeunier, C. J., Denison, J. D., McCarty, G. S., & Sombers, L. A. (2020) · Langmuir · doi:10.1021/acs.langmuir.9b03941 · Cited by 31
“Exposure to tissue induces a significant increase in impedance (F(3,12)=17.”
BackgroundMethodFree‐Standing Nanofilm Electrode Arrays for Long‐Term Stable Neural Interfacings
Gao, L., Wang, J., Zhao, Y., Li, H., Liu, M., Ding, J., Tian, H., Guan, S., & Fang, Y. Z. (2021) · Advanced Materials · doi:10.1002/adma.202107343 · Cited by 30
Perna, A., Angotzi, G. N., Berdondini, L., & Ribeiro, J. F. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1275908 · Cited by 38
Single 5 μm diameter needle electrode block modules for unit recordings in vivo
Sawahata, H., Yamagiwa, S., Moriya, A., Dong, T., Oi, H., Ando, Y., Numano, R., Ishida, M., Koida, K., & Kawano, T. (2016) · Scientific Reports · doi:10.1038/srep35806 · Cited by 29
Sharpened and Mechanically Durable Carbon Fiber Electrode Arrays for Neural Recording
Welle, E. J., Woods, J. E., Jiman, A. A., Richie, J. M., Bottorff, E. C., Ouyang, Z., Seymour, J. P., Patel, P. R., Bruns, T. M., & Chestek, C. A. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3082056 · Cited by 30
“Louis, MO, USA) was electrodeposited onto the exposed carbon of the SCFs by applying 600 pA/channel for 600 s to form poly(3,4-ethylenedioxythiophene):sodium p-toluenesulfonate (PEDOT:pTS) [29], [34].”
BackgroundMethodSelf-citationNeurobiology: rethinking the electrode
Marx, V. (2014) · Nature Methods · doi:10.1038/nmeth.3149 · Cited by 27
Beyond 25 years of biomedical innovation in nano-bioelectronics
Li, P., Kim, S., & Tian, B. (2024) · Device · doi:10.1016/j.device.2024.100401 · Cited by 28
Emerging fiber-based neural interfaces with conductive composites
Won, C., Cho, S., Jang, K., Park, J., Cho, J. H., & Lee, T. (2025) · Materials Horizons · doi:10.1039/d4mh01854k · Cited by 28
Lim, T., Won, S., Kim, M., Trout, M. A., Kim, J., George, J. A., & Zhang, H. (2022) · ACS Materials Letters · doi:10.1021/acsmaterialslett.2c00646 · Cited by 27
Self-citationImplantable neural electrodes: from preparation optimization to application
Zhang, B., Xie, R., Jiang, J., Hao, S., Fang, B., Zhang, J., Bai, H., Peng, B., Li, L., Liu, Z., et al. (2023) · Journal of Materials Chemistry C · doi:10.1039/d2tc05162a · Cited by 28
Caldwell, R., Sharma, R., Takmakov, P. A., Street, M. G., Solzbacher, F., Tathireddy, P., & Rieth, L. W. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.10.002 · Cited by 29
Zargarian, S. S., Rinoldi, C., Ziai, Y., Zakrzewska, A., Fiorelli, R., Gazińska, M. A., Marinelli, M., Majkowska, M., Hottowy, P., Mindur, B. A., et al. (2025) · Small Science · doi:10.1002/smsc.202400463 · Cited by 27
Low-Molecular-Weight Hydrogels as New Supramolecular Materials for Bioelectrochemical Interfaces
Jain, D., Karajić, A., Murawska, M., Goudeau, B., Bichon, S., Gounel, S., Mano, N., Kuhn, A., & Barthélémy, P. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b12890 · Cited by 31
Mind control as a guide for the mind
Medaglia, J. D., Zurn, P., Sinnott-Armstrong, W. P., & Bassett, D. S. (2017) · Nature Human Behaviour · doi:10.1038/s41562-017-0119 · Cited by 29
“At this scale, implanted microsensors record the local activity in neurons [68].”
BackgroundKim, M., Kim, S., Kwon, Y. W., Seo, H., Chung, W. G., Kim, E., Park, W., Song, H., Lee, D. H., Lee, J., et al. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202200049 · Cited by 29
Dissolvable Base Scaffolds Allow Tissue Penetration of High‐Aspect‐Ratio Flexible Microneedles
Yagi, S., Yamagiwa, S., Kubota, Y., Sawahata, H., Numano, R., Imashioya, T., Oi, H., Ishida, M., & Kawano, T. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500305 · Cited by 30
The History and Horizons of Microscale Neural Interfaces
Kozai, T. D. Y. (2018) · Micromachines · doi:10.3390/mi9090445 · Cited by 30
“The level of tissue response is also not limited to pitch, but also depends on the footprint of the probe, shape of tine, and surface chemistry of the interface, making it difficult to translate findings from one design to another [96,99].”
BackgroundSelf-citationNicolai, E. N., Michelson, N. J., Settell, M. L., Hara, S. A., Trevathan, J. K., Asp, A. J., Stocking, K. C., Luján, J. L., Kozai, T. D. Y., & Ludwig, K. A. (2018) · Micromachines · doi:10.3390/mi9100494 · Cited by 27
Self-citationObaid, A., Hanna, M.-E., Huang, S.-W., Hu, Y.-T., Jáidar, O., Nix, W. D., Ding, J., Melosh, N. A., & Wu, Y. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2529147123 · Cited by 34
Recent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25
“…in alphabetical order (Araki et al., 2019; Chiang et al., 2020; Chung et al., 2019; Ferlauto et al., 2021; Guan et al., 2019; Jun et al., 2017; Kozai et al., 2012; Liu et al., 2019, 2020; Luan et al., 2017; Minev et al., 2015; Park et al., 2017, 2021a; Song et al., 2020; Tybrandt et al.,…”
Huang, M., Lee, S., Jo, I., Park, H., Shim, B. S., & Yoon, M. (2023) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2023.121559 · Cited by 25
Fabrication and Evaluation of Cyclic Olefin Copolymer Based Implantable Neural Electrode
Baek, C., Kim, J. J., Lee, Y., & Seo, J.-M. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2963992 · Cited by 28
“able to fabricate ultra-small devices [9], [10].”
Implantable Neural Microelectrodes: How to Reduce Immune Response
Xiang, Y., Zhao, Y., Cheng, T., Sun, S., Wang, J., & Pei, R. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00238 · Cited by 25
Material and design strategies for chronically-implantable neural probes
Liu, F., & Fu, T.-M. (2025) · NPG Asia Materials · doi:10.1038/s41427-025-00613-8 · Cited by 28
“This ultrasmall carbon-fi ber probe achieved stable recording capabilities in rat brains for up to 5 weeks post-implantation 96 .”
InfluentialInsertion mechanics of amorphous SiC ultra-micro scale neural probes
Geramifard, N., Dousti, B., Nguyen, C. K., Abbott, J., Cogan, S. F., & Varner, V. D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5bf4 · Cited by 25
“Recent studies suggest that intracortical single-electrode probes and multi-electrode arrays with ultramicroelectrode cross-sectional dimensions of less than about 10 µ m avoid much of the foreign body response (FBR) associated with larger microelectrode devices [4, 5].”
In Vivo Penetrating Microelectrodes for Brain Electrophysiology
Erofeev, A., Antifeev, I., Bolshakova, A. V., Борисович, Б. И., & Власова, О. Л. (2022) · Sensors · doi:10.3390/s22239085 · Cited by 30
Electrode sharpness and insertion speed reduce tissue damage near high-density penetrating arrays
McNamara, I., Wellman, S. M., Li, L., Eles, J. R., Savya, S. P., Sohal, H. S., Angle, M. R., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad36e1 · Cited by 25
“Considerations should also extend to dielectric stability of low elastic modulus materials [2] and their contribution to performance as well as the fact that decreasing the cross-sectional area of implants can increase the overall flexibility of the device [35].”
BackgroundMethodInfluentialSelf-citationTian, H., Liu, J.-Q., Kang, X.-Y., Tang, L.-J., Wang, M.-H., Bo-Wen, J., Yang, B. T., Wang, X. L., Chen, X., & Yang, C.-S. (2016) · Scientific Reports · doi:10.1038/srep26910 · Cited by 24
Fiáth, R., Hofer, K. T., Csikós, V., Horváth, D., Nánási, T., Tóth, K., Pothof, F., Böhler, C., Asplund, M., Ruther, P., et al. (2018) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2017-0154 · Cited by 27
Model of Impedance Changes in Unmyelinated Nerve Fibers
Tarotin, I., Aristovich, K. Y., & Holder, D. S. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2849220 · Cited by 24
“MEG) [5], are invasive and alter peripheral nerve function and cause significant damage (MEAs) [6] or are expensive, have small fields of view (<1 mm(2)) and therefore insufficient imaging volumes (<1 mm(3)); they also require a high exposure which limits temporal resolution (optical methods) [7], [8].”
BackgroundDweiri, Y. M., Stone, M. A., Tyler, D. J., McCallum, G. A., & Durand, D. M. (2016) · Journal of Visualized Experiments · doi:10.3791/54388 · Cited by 23
Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7493 · Cited by 23
Bioelectronics with graphene nanostructures
Roman, D. S., Garg, R., & Cohen‐Karni, T. (2020) · APL Materials · doi:10.1063/5.0020455 · Cited by 24
Xu, T., Ji, W., Zhang, Y., Wang, X., Gao, N., Mao, L., & Zhang, M. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202204344 · Cited by 23
Qian, S., Lin, H., Pan, Q., Zhang, S., Zhang, Y., Geng, Z. H., Wu, Q. Y., He, Y. W., & Zhu, B. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.02.010 · Cited by 33
“However, these electrode materials were frequently reported to suffer from severe tissue response, as they are susceptible to biofouling [57,59].”
BackgroundIntracranial neuronal ensemble recordings and analysis in epilepsy
Tóth, E., Fabó, D., Entz, L., Ulbert, I., & Erőss, L. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.09.028 · Cited by 24
Saxena, T. K., & Bellamkonda, R. V. (2015) · Nature Materials · doi:10.1038/nmat4454 · Cited by 24
Progress in Research of Flexible MEMS Microelectrodes for Neural Interface
Tang, L., Wang, M., Tian, H., Kang, X., Hong, W., & Liu, J. (2017) · Micromachines · doi:10.3390/mi8090281 · Cited by 25
“Nowadays, some dense electrode arrays and tenuous electrodes are developed to undertake complex and precise electrophysiological research with providing excellent spatial selectivity and low power consumption [2-4].”
BackgroundPlacing Sites on the Edge of Planar Silicon Microelectrodes Enhances Chronic Recording Functionality
Lee, H. C., Gaire, J., Roysam, B., & Otto, K. J. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2715811 · Cited by 23
“Although it has beenwell established that smaller devices induce less biological response [12], [13], small devices are not always the preferred choice considering the trade-off between a device’s sensitivity and resolution.”
BackgroundInkjet-Printed Neural Electrodes with Mechanically Gradient Structure
Kokubo, N., Arake, M., Yamagishi, K., Morimoto, Y., Takeoka, S., Ohta, H., & Fujie, T. (2018) · ACS Applied Bio Materials · doi:10.1021/acsabm.8b00574 · Cited by 24
Lee, Y., Kong, C., Chang, J. W., & Jun, S. B. (2019) · Journal of Korean Medical Science · doi:10.3346/jkms.2019.34.e24 · Cited by 23
Lo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Ahmed, I., Coffey, K. R., Barker, D., Saste, K., Kals, K., Kaplan, H. M., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9fad · Cited by 24
Carbon-Based Fiber Materials as Implantable Depth Neural Electrodes
Fu, X., Li, G., Niu, Y., Xu, J., Wang, P., Zhou, Z., Ye, Z., Liu, X., Xu, Z. J., Yang, Z., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.771980 · Cited by 22
“Carbon fibers (CFs) were used to fabricate electrodes with the assistance of poly (3,4-ethylenedioxythiophene) (PEDOT) coating, which enabled single-neuron recording in acute and early chronic experiments in rats (Kozai et al., 2012; Patel et al., 2016).”
MethodResultZeng, Y., & Lu, J. Q. (2014) · ACS Nano · doi:10.1021/nn505042b · Cited by 23
Kim, C., Jeong, J., & Kim, S. J. (2019) · Sensors · doi:10.3390/s19051069 · Cited by 24
A novel carbon tipped single micro-optrode for combined optogenetics and electrophysiology
Budai, D., Vizvári, A. D., Bali, Z. K., Márki, B., Nagy, L. V., Kónya, Z., Madarász, D., Henn-Mike, N., Varga, C., & Hernádi, I. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193836 · Cited by 25
Sharon, A., Jankowski, M. M., Shmoel, N., Erez, H., & Spira, M. E. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.646914 · Cited by 21
Hou, H., Jin, Y., Wei, H., Ji, W., Xue, Y., Hu, J., Zhang, M., Jiang, Y. Y., & Mao, L. (2020) · Angewandte Chemie · doi:10.1002/ange.202008284 · Cited by 22
Chemical Analysis of the Gallium Surface in a Physiologic Buffer
Lim, T., Ring, T. A., & Zhang, H. (2022) · Langmuir · doi:10.1021/acs.langmuir.1c03281 · Cited by 21
Self-citationEffects of neuronal cell adhesion molecule L1 and nanoparticle surface modification on microglia
Kushwah, N. S., Woeppel, K. M., Dhawan, V., Shi, D., & Cui, X. T. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.06.038 · Cited by 22
Planar Amorphous Silicon Carbide Microelectrode Arrays for Chronic Recording in Rat Motor Cortex
Abbott, J., Jeakle, E. N., Haghighi, P., Usoro, J. O., Sturgill, B. S., Wu, Y., Geramifard, N., Radhakrishna, R., Patnaik, S. S., Nakajima, S., et al. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2024.122543 · Cited by 25
Nanoelectronics for Minimally Invasive Cellular Recordings
Pei, F., & Tian, B. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201906210 · Cited by 22
Zhang, Y., Lin, H., Pan, Q., Qian, S.-H., Zhang, S., Qiu, G., Luo, S., Yu, H., & Zhu, B. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b23025 · Cited by 21
Advanced Electrical and Optical Microsystems for Biointerfacing
Obaid, S. N., Chen, Z., & Lu, L. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000091 · Cited by 22
Hejazi, M. A., Tong, W., Stacey, A. D., Sun, S. H., Yunzab, M., Almasi, A., Jung, Y. J., Hamish Meffin, A., Fox, K. E., Edalati, K., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202006101 · Cited by 22
Electrodeposited Platinum Iridium Enables Microstimulation With Carbon Fiber Electrodes
della Valle, E., Koo, B., Patel, P. R., Whitsitt, Q. A., Purcell, E. K., Chestek, C. A., & Weiland, J. D. (2021) · Frontiers in Nanotechnology · doi:10.3389/fnano.2021.782883 · Cited by 21
“Since carbon is also conductive, it can serve as both a mechanical substrate and electrical conductor for an ultramicroelectrode (Kozai et al., 2012; Patel et al., 2016; Jiman et al., 2020).”
BackgroundInfluentialSelf-citationLiquid Crystalline Polymers: Opportunities to Shape Neural Interfaces
Rihani, R. T., Tasnim, N., Javed, M., Usoro, J. O., D'Souza, T. M., Ware, T. H., & Pancrazio, J. J. (2021) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.13364 · Cited by 23
Metadata
- Authors
- Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- New York State Department of Health (US)
- Corresponding author
- Kozai, Takashi D. Yoshida
- Kotov, Nicholas A.
- Kipke, Daryl R.
- ORCID
- Venue
- Nature Materials
- Published
- 2012-11-11
- Volume
- 11
- Issue
- 12
- Pages
- 1065-1073
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- PMC
- PMC3524530
- OpenAlex
- W2055432244
- Semantic Scholar
- 95f8a36bd5f96433b3c1187417d67af078621c37
- Cited by
- 721
- References
- 52
- Citations by year
- 2026: 26 · 2025: 45 · 2024: 43 · 2023: 57 · 2022: 52 · 2021: 72 · 2020: 74 · 2019: 67 · 2018: 62 · 2017: 64 · 2016: 50 · 2015: 53 · 2014: 36 · 2013: 19
- FWCI
- 14.23
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Materials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (1RC1NS068396-0110, RC1NS068396)
- National Institute of Biomedical Imaging and Bioengineering (P41EB002030)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- carbon fiber electrodes, dielectric barrier, bioactive surfaces, single-unit recording, brain-computer interface, extracellular recording
- MeSH terms
- Carbon Fiber, Animals, Carbon, Electrodes, Implanted, Microelectrodes, Rats, Synaptic Potentials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.