Fabrication of High Contact-Density, Flat-Interface Nerve Electrodes for Recording and Stimulation Applications
Open accessAbstract
Many attempts have been made to manufacture multi-contact nerve cuff electrodes that are safe, robust and reliable for long term neuroprosthetic applications. This protocol describes a fabrication technique of a modified cylindrical nerve cuff electrode to meet these criteria. Minimum computer-aided design and manufacturing (CAD and CAM) skills are necessary to consistently produce cuffs with high precision (contact placement 0.51 ± 0.04 mm) and various cuff sizes. The precision in spatially distributing the contacts and the ability to retain a predefined geometry accomplished with this design are two criteria essential to optimize the cuff's interface for selective recording and stimulation. The presented design also maximizes the flexibility in the longitudinal direction while maintaining sufficient rigidity in the transverse direction to reshape the nerve by using materials with different elasticities. The expansion of the cuff's cross sectional area as a result of increasing the pressure inside the cuff was observed to be 25% at 67 mm Hg. This test demonstrates the flexibility of the cuff and its response to nerve swelling post-implant. The stability of the contacts' interface and recording quality were also examined with contacts' impedance and signal-to-noise ratio metrics from a chronically implanted cuff (7.5 months), and observed to be 2.55 ± 0.25 kΩ and 5.10 ± 0.81 dB respectively.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Cuff electrode failure modes after implantation include lead breakage, closing site failure, motion artifacts, and connection failure.
“Several failure modes have been reported including lead breakage, closing site failure, motion artifacts, and connection failure [77].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [77]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · see citing works
Self-citationKozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · see citing works
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · see citing works
Effects of graded compression on intraneural blood flow
Rydevik, B. L., Lundborg, G., & BAGGE, U. (1981) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(81)80003-2 · Cited by 466 · see citing works
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · see citing works
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · see citing works
Self-citationLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · see citing works
Blood Flow of Peripheral Nerve Effects of Dissection, Stretching and Compression
OGATA, K., & NAITO, M. (1986) · Journal of Hand Surgery (European Volume) · doi:10.1016/0266-7681(86)90003-3 · Cited by 245 · see citing works
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215 · see citing works
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · see citing works
Schüettler, M., Stieß, S., King, B. V., & Suaning, G. J. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/013 · Cited by 163 · see citing works
Stable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160 · see citing works
Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144 · see citing works
Self-citationExperimental Improvements in the Use of Silastic Cuff for Peripheral Nerve Repair
Ducker, T. B., Hayes, G. J., & General, B. (1968) · Journal of neurosurgery · doi:10.3171/jns.1968.28.6.0582 · Cited by 137 · see citing works
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · see citing works
Self-citationMicera, S., Citi, L., Rigosa, J., Carpaneto, J., Raspopović, S., Pino, G. D., Rossini, L., Yoshida, K., Denaro, L., Dario, P., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038726 · Cited by 100 · see citing works
A flexible method for fabrication of nerve cuff electrodes
Haugland, M. K. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.656992 · Cited by 79 · see citing works
Tripolar nerve cuff recording: stimulus artifact, EMG and the recorded nerve signal
Struijk, J. J., & Thomsen, M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1995.579534 · Cited by 76 · see citing works
Single unit conduction velocities from averaged nerve cuff electrode records in freely moving cats
Hoffer, J. A., Loeb, G. E., & Pratt, C. A. (1981) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(81)90033-9 · Cited by 73 · see citing works
Electroneurographic recordings with polymer cuff electrodes in paralyzed cats
Julien, C., & Rossignol, S. (1982) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(82)90078-4 · Cited by 54 · see citing works
Selective Stimulation of the Canine Hypoglossal Nerve Using a Multi-contact Cuff Electrode
Yoo, P. B., Şahin, M., & Durand, D. M. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000019170.74375.fb · Cited by 48 · see citing works
Self-citationRozman, J., Zorko, B., & Bunc, M. (2000) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.50.509 · Cited by 34 · see citing works
Electrical stimulation of the brain. I. Electrodes and electrode arrays.
Rh, P., Bullara, L. A., & Talalla, A. (1975) · PubMed · Cited by 26 · see citing works
Charged by GSK investment, battery of electroceuticals advance
Sinha, G. (2013) · Nature Medicine · doi:10.1038/nm0613-654 · Cited by 18 · see citing works
Enhanced electrode design for peripheral nerve recording
Sadeghlo, B., & Yoo, P. B. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696218 · Cited by 12 · see citing works
Extracting Command Signals From Peripheral Nerve Recordings
Wodlinger, B. (2010) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- Van der Puije, P. D., Shelley, R., & Loeb, G. E. A self-spiraling thin-film nerve cuff electrode. Can Med Bio Eng Conf. 186-187 (1993).
- Craggs, M. D. The cortical control of limb prostheses. PhD Thesis U of Lon., pp 21-7 (1974).
Cited by
Sorted by citations
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609 · see citing works
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113 · see citing works
“Several failure modes have been reported including lead breakage, closing site failure, motion artifacts, and connection failure [77].”
BackgroundThin film multi-electrode softening cuffs for selective neuromodulation
González-González, M. A., Kanneganti, A., Joshi-Imre, A., Hernandez-Reynoso, A. G., Bendale, G., Modi, R., Ecker, M., Khurram, A., Cogan, S. F., Voit, W. E., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-34566-6 · Cited by 97 · see citing works
Vagus Nerve Stimulation in Rodent Models: An Overview of Technical Considerations
Noller, C. M., Levine, Y. A., Urakov, T. M., Aronson, J. P., & Nash, M. S. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00911 · Cited by 69 · see citing works
Ravagli, E., Mastitskaya, S., Thompson, N., Iacoviello, F., Shearing, P. R., PERKINS, J. D., Gourine, A. V., Aristovich, K. Y., & Holder, D. S. (2020) · Nature Communications · doi:10.1038/s41467-020-20127-x · Cited by 53 · see citing works
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54 · see citing works
Self-citationAristovich, K. Y., Donegà, M., Blochet, C., Avery, J., Hannan, S., Chew, D. J., & Holder, D. S. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aad78e · Cited by 52 · see citing works
Separability of neural responses to standardised mechanical stimulation of limbs
Brunton, E., Blau, C. W., & Nazarpour, K. (2017) · Scientific Reports · doi:10.1038/s41598-017-11349-z · Cited by 27 · see citing works
Model-based Bayesian signal extraction algorithm for peripheral nerves
Eggers, T. E., Dweiri, Y. M., McCallum, G. A., & Durand, D. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7d94 · Cited by 17 · see citing works
Self-citationPayne, S. C., Burns, O., Stebbing, M. J., Thomas, R., de Silva, A., Sedó, A., Weissenborn, F., Hyakumura, T., Huynh, M., May, C. N., et al. (2018) · Bioelectronics in Medicine · doi:10.2217/bem-2018-0011 · Cited by 17 · see citing works
Karczewski, A. M., Dingle, A. M., & Poore, S. O. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.711028 · Cited by 13 · see citing works
Recovering Motor Activation with Chronic Peripheral Nerve Computer Interface
Eggers, T. E., Dweiri, Y. M., McCallum, G. A., & Durand, D. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-32357-7 · Cited by 13 · see citing works
Self-citationRapid and Low Cost Manufacturing of Cuff Electrodes
Flavin, M. T., Paul, M. A., Lim, A. S., Abdul‐Hamed, S., Lissandrello, C. A., Ajemian, R., Lin, S. J., & Han, J. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.628778 · Cited by 11 · see citing works
Kotamraju, B. P., Eggers, T. E., McCallum, G. A., & Durand, D. M. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad1611 · Cited by 9 · see citing works
Self-citationOpen-source Toolkit: Benchtop Carbon Fiber Microelectrode Array for Nerve Recording
Richie, J. M., Patel, P. R., Welle, E. J., Dong, T., Chen, L., Shih, A. J., & Chestek, C. A. (2021) · Journal of Visualized Experiments · doi:10.3791/63099 · Cited by 10 · see citing works
Petros, E., Miller, M., Dunning, J. L., Pinault, G. C. J., Tyler, D. J., Triolo, R. J., & Charkhkar, H. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada829 · Cited by 7 · see citing works
Self-citationPayne, S. C., Osborne, P. B., Thompson, A., Eiber, C. D., Keast, J. R., & Fallon, J. B. (2023) · APL Bioengineering · doi:10.1063/5.0164951 · Cited by 5 · see citing works
Utilization of peripheral nerve feedback at a preconscious level
Chowdhury, N. H., & Tyler, D. J. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1336431 · Cited by 5 · see citing works
Self-citationBending Properties of Materials for Peripheral Nerve Interfaces
Woods, J. E., Welle, E. J., Chen, L., Richie, J. M., Patel, P. R., & Chestek, C. A. (2020) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems50311.2020.9265629 · Cited by 5 · see citing works
Isoflurane anesthesia suppresses gastric myoelectric power in the ferret
Tomaselli, L., Sciullo, M., Fulton, S., Yates, B. J., Fisher, L. E., Ventura, V., & Horn, C. C. (2024) · Neurogastroenterology & Motility · doi:10.1111/nmo.14749 · Cited by 4 · see citing works
Methods of integrating the human nervous system with electronic circuits
Skok, T., Tabakow, P., & Chmielak, K. (2019) · Advances in Clinical and Experimental Medicine · doi:10.17219/acem/103414 · Cited by 3 · see citing works
Zhao, C., Zheng, C., Roldan, L. M., Shkurti, T. E., Nahari, A., Newman, W. S., Tyler, D. J., Lee, K., & Fu, M. J. (2023) · Field Robotics · doi:10.55417/fr.2023007 · Cited by 2 · see citing works
Self-citationDirect Prosthesis Force Control with Tactile Feedback May Connect with the Internal ModelPreprint
Chowdhury, N. H., Schramfield, S., Pariseau, P., & Tyler, D. J. (2024) · medRxiv · doi:10.1101/2024.12.05.24318338 · Cited by 1 · see citing works
Self-citation
- Authors
- Dweiri, Y. M., Stone, M. A., Tyler, D. J., McCallum, G. A., & Durand, D. M.
- Affiliations
- Jordan University of Science and Technology (JO)
- United States Department of Veterans Affairs (US)
- Case Western Reserve University (US)
- Venue
- Journal of Visualized Experiments
- Publisher
- MyJove Corporation
- Published
- 2016-10-04
- Issue
- 116
- ISSN
- 1940-087X (ISSN-L)
- PMC
- PMC5092158
- OpenAlex
- W2529404661
- Cited by
- 23
- References
- 27
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 3 · 2021: 4 · 2020: 3 · 2019: 2 · 2018: 4 · 2017: 3
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Visualized Experiments (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Defense Advanced Research Projects Agency (N66001-12-C-4173)
- Advanced Research Projects Agency
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › Undergraduate Neuroscience Education and Research
- Keywords
- cuff electrodes, neural recording, neurostimulation, neuroprosthetics, electrode fabrication, contact density, flat interface, nerve swelling, contact impedance, signal-to-noise ratio, chronic implantation, CAD/CAM manufacturing
- MeSH terms
- Electric Stimulation, Electrodes, Electrodes, Implanted, Equipment Design, Peripheral Nerves, Computer-Aided Design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review