Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Implantable neural microelectrodes that can record extracellular biopotentials from small, targeted groups of neurons are critical for neuroscience research and emerging clinical applications including brain-controlled prosthetic devices. The crucial material-dependent problem is developing microelectrodes that record neural activity from the same neurons for years with high fidelity and reliability. Here, we report the development of an integrated composite electrode consisting of a carbon-fibre core, a poly(p-xylylene)-based thin-film coating that acts as a dielectric barrier and that is functionalized to control intrinsic biological processes, and a poly(thiophene)-based recording pad. The resulting implants are an order of magnitude smaller than traditional recording electrodes, and more mechanically compliant with brain tissue. They were found to elicit much reduced chronic reactive tissue responses and enabled single-neuron recording in acute and early chronic experiments in rats. This technology, taking advantage of new composites, makes possible highly selective and stealthy neural interface devices towards realizing long-lasting implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The microscale geometries presented in (A-C) are each associated with an improved tissue response to the implant.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [71]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [312]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Coating the electrode site with poly(3,4-ethylenedioxythiphene) (PED-OT) facilitates signal detection.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [71]
The cited source says what the claim attributes to it.
In the citing paper
“Next-generation devices fabricated from parylene-insulated carbon fibers with antibiofouling poly(ethylene glycol) methacrylate coatings have demonstrated robust recording quality and a minimal accompanying tissue response (Fig. 3C).71”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [71]
The cited source says what the claim attributes to it.
In the citing paper
“While the smaller electrode sites necessitated by finer-scale geometries have the drawback of increased impedance, inclusion of conductive polymers mitigates this effect and allows improved signal detection.71,72”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [71]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
A controlled cortical impact model of traumatic brain injury in the rat
Edward Dixon, C., Clifton, G. L., Lighthall, J. W., Yaghmai, A. A., & Hayes, R. L. (1991) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(91)90104-8 · Cited by 1,141
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Unterberg, A. W., Stover, J., Kress, B., & Kiening, K. L. (2004) · Neuroscience · doi:10.1016/j.neuroscience.2004.06.046 · Cited by 881
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Self-citationLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citation
Cited by
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
3D printing of conducting polymers
Yuk, H., Lu, B., Lin, S., Qu, K., Xu, J., Luo, J., & Zhao, X. (2020) · Nature Communications · doi:10.1038/s41467-020-15316-7 · Cited by 1,001
Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“Likewise, impedance can be especially difficult to interpret for emerging biomaterials with high ratios of electrochemical surface area to geometric surface area, for which the surface topography and chronic glia–surface interaction remain difficult to characterize 48 .”
InfluentialSelf-citationBrain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Self-citationUltraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Cheng, C., Li, S., Thomas, A., Kotov, N. A., & Haag, R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00520 · Cited by 527
Self-citationYu, K. J., Kuzum, D., Hwang, S.-W., Kim, B. H., Juul, H., Kim, N. H., Won, S. M., Chiang, K., Trumpis, M., Richardson, A. G., et al. (2016) · Nature Materials · doi:10.1038/nmat4624 · Cited by 523
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Wireless Optofluidic Systems for Programmable In Vivo Pharmacology and Optogenetics
Jeong, J.-W., McCall, J. G., Shin, G., Zhang, Y., Al-Hasani, R., Kim, M., Li, S., Sim, J. Y., Jang, K.-I., Shi, Y., et al. (2015) · Cell · doi:10.1016/j.cell.2015.06.058 · Cited by 498
“These thin, flexible optofluidic neural probes are better tolerated by the brain than rigid implants, consistent with previous reports of ultrathin, flexible deep brain implants (Canales et al., 2015; Capadona et al., 2012; Kim et al., 2013b; Kozai and Kipke, 2009; Kozai et al., 2012).”
Solution-processable, soft, self-adhesive, and conductive polymer composites for soft electronics
Tan, P., Wang, H., Xiao, F., Lu, X., Shang, W., Deng, X., Song, H., Xu, Z., Cao, J., Gan, T., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28027-y · Cited by 403
Self-citationThree-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
“…of syringe injected mesh electronics 32 , although conventional micro-wire 4, 25 and silicon 19, 43 neural probes as well as ultra-small but rigid 14 and flexible two-dimensional polymer probes 16, 17 show enhanced GFAP/astrocyte proliferation and a reduction of neuron density near these probe…”
BackgroundMethodInfluentialShin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
“Techniques in electrical brain stimulation, based on penetrating or surface mounted electrodes, represent the most traditional means for activating neurons to determine their roles in cognitive function (Campbell et al., 1991; Cogan, 2008; Kozai et al., 2012).”
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Self-citationIwata, M., Ota, K. T., Li, X.-Y., Sakaue, F., Li, N., Dutheil, S., Banasr, M., Duric, V., Yamanashi, T., Kaneko, K., et al. (2016) · Biological Psychiatry · doi:10.1016/j.biopsych.2015.11.026 · Cited by 387
“Second, we perfused the inserted probe for 18 hours before sample collection, whereas the previous study started collection 1 hour after probe insertion, and analysis could be confounded by acute tissue damage, activated microglia, and reactive astrocytes around the insertion site (52,53).”
Wang, L., Xie, S., Wang, Z., Liu, F., Yang, Y., Tang, C., Wu, X., Liu, P., Li, Y., Saiyin, H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0462-8 · Cited by 384
Flexible brain–computer interfaces
Tang, X., Shen, H., Zhao, S., Li, N., & Liu, J. (2023) · Nature Electronics · doi:10.1038/s41928-022-00913-9 · Cited by 373
“The initial stable recording could then be used as training data in machine-learning-based algorithms for patient-specific, self-programmable and energy-efficient long-term stable decoding.”
MethodBioinspired neuron-like electronics
Yang, X., Zhou, T., Zwang, T. J., Hong, G., Zhao, Y., Viveros, R. D., Fu, T.-M., Gao, T., & Lieber, C. M. (2019) · Nature Materials · doi:10.1038/s41563-019-0292-9 · Cited by 384
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“Reprinted with permission from [321], Copyright 2012 Nature Publishing Group.”
BackgroundMethodOrgan-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Self-citationStable long-term chronic brain mapping at the single-neuron level
Fu, T.-M., Hong, G., Zhou, T., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2016) · Nature Methods · doi:10.1038/nmeth.3969 · Cited by 330
Neural Stimulation and Recording with Bidirectional, Soft Carbon Nanotube Fiber Microelectrodes
Vitale, F., Summerson, S. R., Aazhang, B., Kemere, C., & Pasquali, M. (2015) · ACS Nano · doi:10.1021/acsnano.5b01060 · Cited by 311
Functional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 308
Emerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
High‐Density Stretchable Electrode Grids for Chronic Neural Recording
Tybrandt, K., Khodagholy, D., Dielacher, B., Stauffer, F., Renz, A. F., Buzsáki, G., & Vörös, J. (2018) · Advanced Materials · doi:10.1002/adma.201706520 · Cited by 286
The Future of Layer-by-Layer Assembly: A Tribute to ACS Nano Associate Editor Helmuth Möhwald
Zhao, S., Caruso, F., Dähne, L., Decher, G., De Geest, B. G., Fan, J., Feliu, N., Gogotsi, Y., Hammond, P. T., Hersam, M. C., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b03326 · Cited by 283
Self-citationZhu, S., Yang, Q., Antaris, A. L., Yue, J., Ma, Z., Wang, H., Huang, W., Wan, H., Wang, J., Diao, S., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1617990114 · Cited by 279
“3 C–F shows the 2D three-color [850–900 nm labels for cell nuclei, 1,050–1,300 nm for neurons (44), and 1,500–1,700 nm for blood vessels] images of each molecular feature in addition to the multicolor overlay.”
BackgroundLayer-by-Layer Assembly for Graphene-Based Multilayer Nanocomposites: Synthesis and Applications
Lee, T., Min, S. H., Gu, M., Jung, Y. K., Lee, W., Lee, J. U., Seong, D. G., & Kim, B.-S. (2015) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b00491 · Cited by 277
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
“A number of studies have reported the benefits of small implant size [20,21], implant flexibility [22e29] and the use of neurointegrative and anti-inflammatory bioactive coatings [30e33].”
BackgroundZhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review
Rodrigues, D., Barbosa, A. I., Rebelo, R., Kwon, I. K., Reis, R. L., & Correlo, V. M. (2020) · Biosensors · doi:10.3390/bios10070079 · Cited by 220
“In electrochemical biosensors, signal-to-noise ratio is key for detection, especially in wearable and implantable systems where concomitant noise is significant [19,20].”
BackgroundZhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705509114 · Cited by 227
“Recent studies have investigated the potential advantages of reducing mechanical stiffness (19–21), feature sizes (22), as well as density of the material used for fabrication of probes (15) in terms of reduced gliosis.”
BackgroundRodeberg, N. T., Sandberg, S. G., Johnson, J. A., Phillips, P. E. M., & Wightman, R. M. (2017) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.6b00393 · Cited by 226
A carbon-fiber electrode array for long-term neural recording
Guitchounts, G., Markowitz, J. E., Liberti, W. A., & Gardner, T. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046016 · Cited by 224
Elastocapillary self-assembled neurotassels for stable neural activity recordings
Guan, S., Wang, J., Gu, X., Zhao, Y., Hou, R., Fan, H., Zou, L., Gao, L., Du, M., Li, C., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav2842 · Cited by 222
State-of-the-art MEMS and microsystem tools for brain research
Seymour, J. P., Wu, F., Wise, K. D., & Yoon, E. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.66 · Cited by 216
Kozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218
“More importantly, these sub-cellular featured microelectrodes have been shown to improve longitudinal recording performance [26,118].”
InfluentialSelf-citationConjugated Polymers for Assessing and Controlling Biological Functions
Zeglio, E., Rutz, A. L., Winkler, T. E., Malliaras, G. G., & Herland, A. (2019) · Advanced Materials · doi:10.1002/adma.201806712 · Cited by 210
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Self-citationRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
“Unfortunately, the lack of a macroscopic scar seen in previous carbon fiber work [41] and confirmed here, makes it difficult to account for the impedance increase seen with the carbon fibers.”
BackgroundMethodResultInfluentialSelf-citationIn Vivo Biosensing: Progress and Perspectives
Rong, G., Corrie, S. R., & Clark, H. A. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00834 · Cited by 199
Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study
Boehler, C., Kleber, C., Martini, N., Xie, Y., Dryg, I., Stieglitz, T., Hofmann, U. G., & Asplund, M. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.019 · Cited by 196
Zhang, Y., Mickle, A. D., Gutruf, P., McIlvried, L. A., Guo, H., Wu, Y., Golden, J. P., Xue, Y., Grajales-Reyes, J. G., Wang, X., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw5296 · Cited by 195
Kozai, T. D. Y., Gugel, Z., Li, X., Gilgunn, P. J., Khilwani, R., Ozdoganlar, O. B., Fedder, G. K., Weber, D. J., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.07.039 · Cited by 193
“Astrocyte activation in the microwire implanted tissue quantified by GFAP generally closely mirrored expression patterns previously described throughout the literature [12,14,55].”
BackgroundMethodInfluentialSelf-citationChronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings
Kozai, T. D. Y., Catt, K., Du, Z., Na, K., Srivannavit, O., Haque, R.-U. M., Seymour, J., Wise, K. D., Yoon, E., & Cui, X. T. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2445713 · Cited by 197
“carried out using a custom MATLAB script modified from previously published methods [9], [31].”
InfluentialSelf-citationHigh‐Performance Graphene‐Fiber‐Based Neural Recording Microelectrodes
Wang, K., Frewin, C. L., Esrafilzadeh, D., Yu, C., Wang, C., Pancrazio, J. J., Romero‐Ortega, M., Jalili, R., & Wallace, G. (2019) · Advanced Materials · doi:10.1002/adma.201805867 · Cited by 191
Parylene-based flexible neural probes with PEDOT coated surface for brain stimulation and recording
Castagnola, V., Descamps, E., Lecestre, A., Dahan, L., Remaud, J., Nowak, L. G., & Bergaud, C. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.004 · Cited by 183
Takmakov, P., Ruda, K., Scott Phillips, K., Isayeva, I. S., Krauthamer, V., & Welle, C. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026003 · Cited by 178
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
Ma, L., Qin, H., Cheng, C., Xia, Y., He, C., Nie, C., Wang, L., & Zhao, C. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21388a · Cited by 177
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
“Surfaces of electrodes are being functionalized, to reduce the tissue inflammatory responses at the implant site [4, 99].”
BackgroundMethodInfluentialOrganic Bioelectronics: From Functional Materials to Next‐Generation Devices and Power Sources
Ohayon, D., & Inal, S. (2020) · Advanced Materials · doi:10.1002/adma.202001439 · Cited by 175
Zhao, Z., Zhu, H., Li, X., Sun, L., He, F., Chung, J. E., Liu, D. F., Frank, L., Luan, L., & Xie, C. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00941-y · Cited by 172
Large enhancement in neurite outgrowth on a cell membrane-mimicking conducting polymer
Zhu, B., Luo, S.-C., Zhao, H., Lin, H.-A., Sekine, J., Nakao, A., Chen, C., Yamashita, Y., & Yu, H.-H. (2014) · Nature Communications · doi:10.1038/ncomms5523 · Cited by 171
Progress in heparin and heparin-like/mimicking polymer-functionalized biomedical membranes
Cheng, C., Sun, S., & Zhao, C. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb01390e · Cited by 169
Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 172
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
“Apart from metals, also carbon fibers have been reported to form wire-based arrays (Kozai et al., 2012).”
BackgroundSoft Fiber Electronics Based on Semiconducting Polymer
Sun, F., Jiang, H., Wang, H., Zhong, Y., Xu, Y., Xing, Y., Yu, M., Feng, L.-W., Tang, Z., Liu, J., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00720 · Cited by 164
Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 162
Self-citationImplantable bioelectronics toward long-term stability and sustainability
Li, Y., Li, N., Oliveira, N. D., & Wang, S. (2021) · Matter · doi:10.1016/j.matt.2021.02.001 · Cited by 168
“, poly(ethylene glycol) [PEG]), Si and carbon fibers are more susceptible to biofouling, thereby eliciting more severe tissue response.(46) The redox state of polypyrrole, a conducting polymer, has been found to influence the fibronectin conformation and affect cell attachment and growth.”
BackgroundMesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
“In comparison, the overall sizes of silicon microelectrode arrays are almost always >4 times larger than a single neuron regardless of channel numbers [7], and microwire-based brain probes become significantly larger than neuron somata with increasing channel numbers, despite subcellular feature size for single-channe…”
Battery-free, lightweight, injectable microsystem for in vivo wireless pharmacology and optogenetics
Zhang, Y., Castro, D. C., Han, Y., Wu, Y., Guo, H., Weng, Z., Xue, Y., Ausra, J., Wang, X., Li, R., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1909850116 · Cited by 160
Flexible Electrodes for In Vivo and In Vitro Electrophysiological Signal Recording
Zhu, M., Wang, H., Li, S., Liang, X., Zhang, M., Dai, X., & Zhang, Y. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100646 · Cited by 171
Nanofabricated Neural Probes for Dense 3-D Recordings of Brain Activity
Rios, G., Lubenov, E. V., Chi, D., Roukes, M. L., & Siapas, A. G. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b02673 · Cited by 161
Apollo, N. V., Maturana, M. I., Tong, W., Nayagam, D. A. X., Shivdasani, M. N., Foroughi, J., Wallace, G. G., Prawer, S., Ibbotson, M. R., & Garrett, D. J. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500110 · Cited by 152
Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology
Fu, T.-M., Hong, G., Viveros, R. D., Zhou, T., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1717695114 · Cited by 155
Kozai, T. D. Y., & Vazquez, A. L. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00108k · Cited by 150
Self-citationXue, Y., Chen, X., Wang, F., Lin, J., & Liu, J. (2023) · Advanced Materials · doi:10.1002/adma.202304095 · Cited by 184
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
“Histological comparisons of tissue reactions to chronically implanted carbon fiber show a significant reduction in foreign body responses than that seen with silicon probes in rodents (Kozai et al., 2012).”
BackgroundInfluentialSoft and MRI Compatible Neural Electrodes from Carbon Nanotube Fibers
Lu, L., Fu, X., Liew, Y., Zhang, Y., Zhao, S., Xu, Z., Zhao, J., Li, D., Li, Q., Stanley, G. B., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b04456 · Cited by 146
Nanofabricated Ultraflexible Electrode Arrays for High‐Density Intracortical Recording
Wei, X., Luan, L., Zhao, Z., Li, X., Zhu, H., Potnis, O., & Xie, C. (2018) · Advanced Science · doi:10.1002/advs.201700625 · Cited by 146
Implantable intracortical microelectrodes: reviewing the present with a focus on the future
Wang, Y., Yang, X., Zhang, X., Wang, Y., & Pei, W. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00451-6 · Cited by 162
Chronically Implanted Intracranial Electrodes: Tissue Reaction and Electrical Changes
Campbell, A., & Wu, C. (2018) · Micromachines · doi:10.3390/mi9090430 · Cited by 164
“Newer generations of electrodes have become considerably smaller and thinner, and it has been shown that smaller implants lead to less initial tissue damage, decreased neuronal loss in the vicinity of the electrode, and reduced chronic tissue responses [15,16].”
BackgroundTranslational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 160
A review of electrodes for the electrical brain signal recording
Im, C., & Seo, J.-M. (2016) · Biomedical Engineering Letters · doi:10.1007/s13534-016-0235-1 · Cited by 154
“Their footprints are small enough to reduce neuronal damage and enhance biocompatibility [42, 43].”
BackgroundKozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Self-citationIn Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating
Alba, N., Du, Z., Catt, K., Kozai, T., & Cui, X. (2015) · Biosensors · doi:10.3390/bios5040618 · Cited by 137
“geometric surface area, and can be applied using electrochemical synthesis directly onto recording site surfaces [23,51,54,55,62].”
BackgroundSelf-citationKozai, T. D. Y., Du, Z., Gugel, Z. V., Smith, M. A., Chase, S. M., Bodily, L. M., Caparosa, E. M., Friedlander, R. M., & Cui, X. T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.12.010 · Cited by 138
Self-citationFlexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 134
From the beaker to the body: translational challenges for electrochemical, aptamer-based sensors
Arroyo-Currás, N., Dauphin-Ducharme, P., Scida, K., & Chávez, J. L. (2020) · Analytical Methods · doi:10.1039/d0ay00026d · Cited by 129
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
“…next silicon-based microfabricated electrode arrays, and most recently advanced two-and three-dimensional arrays ( 33 ) and integrated microelectrodes and circuits have greatly advanced the ability to record electrophysiological activity from a large number of neurons simultaneously ( 34–36 ).”
BackgroundTracking neural activity from the same cells during the entire adult life of mice
Zhao, S., Tang, X., Tian, W., Partarrieu, S., Liu, R., Shen, H., Lee, J. Y., Guo, S., Lin, Z., & Liu, J. (2023) · Nature Neuroscience · doi:10.1038/s41593-023-01267-x · Cited by 140
Kolarcik, C. L., Catt, K., Rost, E., Albrecht, I. N., Bourbeau, D., Du, Z., Kozai, T. D. Y., Luo, X., Weber, D. J., & Tracy Cui, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016008 · Cited by 126
“Furthermore, ultrasmall electrodes may be needed to extend early benefits to long-term performance [23, 24].”
BackgroundSelf-citationThiol‐ene/acrylate substrates for softening intracortical electrodes
Ware, T., Simon, D., Liu, C., Musa, T., Vasudevan, S., Sloan, A., Keefer, E. W., Rennaker, R. L., & Voit, W. (2014) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbmb.32946 · Cited by 126
Michelson, N. J., Vazquez, A. L., Eles, J. R., Salatino, J. W., Purcell, E. K., Williams, J. J., Cui, X. T., & Kozai, T. D. Y. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9dae · Cited by 133
Self-citationThe Argo: a high channel count recording system for neural recording in vivo
Sahasrabuddhe, K., Khan, A. A., Singh, A. P., Stern, T. M., Ng, Y., Tadić, A., Orel, P., LaReau, C., Pouzzner, D., Nishimura, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd0ce · Cited by 124
Self-citationLee, J. H., Kim, H., Kim, J. H., & Lee, S.-H. (2016) · Lab on a Chip · doi:10.1039/c5lc00842e · Cited by 124
A Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces
Ferguson, M., Sharma, D., Ross, D., & Zhao, F. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900558 · Cited by 134
Metadata
- Authors
- Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- New York State Department of Health (US)
- Corresponding author
- Kozai, Takashi D. Yoshida
- Kotov, Nicholas A.
- Kipke, Daryl R.
- ORCID
- Venue
- Nature Materials
- Published
- 2012-11-11
- Volume
- 11
- Issue
- 12
- Pages
- 1065-1073
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- PMC
- PMC3524530
- OpenAlex
- W2055432244
- Semantic Scholar
- 95f8a36bd5f96433b3c1187417d67af078621c37
- Cited by
- 721
- References
- 52
- Citations by year
- 2026: 26 · 2025: 45 · 2024: 43 · 2023: 57 · 2022: 52 · 2021: 72 · 2020: 74 · 2019: 67 · 2018: 62 · 2017: 64 · 2016: 50 · 2015: 53 · 2014: 36 · 2013: 19
- FWCI
- 14.23
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Materials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (1RC1NS068396-0110, RC1NS068396)
- National Institute of Biomedical Imaging and Bioengineering (P41EB002030)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- carbon fiber electrodes, dielectric barrier, bioactive surfaces, single-unit recording, brain-computer interface, extracellular recording
- MeSH terms
- Carbon Fiber, Animals, Carbon, Electrodes, Implanted, Microelectrodes, Rats, Synaptic Potentials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.