Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,242

The DOI matches its Crossref record.

Prevention of overfitting in cryo-EM structure determination

Open access
Scheres, Sjors H W, Chen, Shaoxia·2012·Nature Methods

Abstract

In the field of single-particle analysis of electron cryo-microscopy (cryo-EM) data, a growing concern that some resolution claims might not be substantiated by the data has been one of the instigators of community-wide efforts to develop new validation tools1. A known issue with commonly used cryo-EM structure determination procedures is their liability to overfit the data. Most procedures counter overfitting by low-pass filtering, but the effective frequencies for these filters are often based on suboptimal Fourier Shell Correlation2 (FSC) procedures. In the suboptimal procedure, FSC curves are calculated between reconstructions from two halves of the data, while a single model is used to determine the relative orientations of all particles. It is well known that bias towards noise in the single model may inflate the resulting resolution estimates. To illustrate this, we applied the suboptimal procedure to a simulated cryo-EM data set of 20,212 GroEL particles. Whereas the reported resolution was 4.6 A, the true resolution of the map was only 7.8 A. Also the presence of expected density features in the map does not necessarily provide sufficient evidence for a resolution claim: we could make convincingly looking figures of apparent side-chain density that in reality corresponded to overfitted noise (Supplementary Figure 1). Consequently, overfitting may remain undetected and interpretation of cryo-EM maps may be subject to errors. The dangers of overfitting have been recognized, and refinement procedures with resolution-dependent weighting schemes to reduce overfitting have been proposed3,4. However, two known solutions to prevent it are not in common use. By refining two models independently (one for each half of the data), so-called gold-standard1 FSC curves may be calculated that are free from spurious correlations. Alternatively, the data used for the orientation determination may be limited to a user-specified frequency, so that model bias beyond that frequency may be avoided. However, the argument that withholding part of the data from the refinement would substantially deteriorate the orientations and thereby the quality of the structure has prevented the wide-spread use of either of these solutions. In what follows, we prove this thesis to be false. Analysis of simulated data with realistic signal-to-noise ratios (SNRs) indicates that the accuracy of the orientation determination is not affected by the exclusion of high-frequency terms, nor by the use of a model that is reconstructed from only half of the particles (Supplementary Figure 2). These simulations illustrate that only the low-medium frequency terms in the individual particles contain sufficiently high SNRs to contribute significantly to the orientation determination, which is in good agreement with experimental evidence that cryo-EM particles may be aligned accurately using only low-frequency data5. Because in most cryo-EM studies the low-medium frequencies of reconstructions from half of the particles are not expected to be significantly worse than those of reconstructions from all particles, we hypothesize that overfitting may be prevented without a notable loss of resolution using either frequency-limited refinement or refinement based on gold-standard FSCs. Since the former involves a decision by the user, i.e. choosing the frequency at which to limit the refinement, we favour gold-standard FSCs and implemented a procedure to independently refine two models as a script on top of the conventional projection matching protocol in the XMIPP package6 (Supplementary Figure 3 & Supplementary Software). We tested our hypothesis using three cryo-EM data sets: 5,053 GroEL particles that are distributed by the National Center for Macromolecular Imaging; an in-house collected data set of 50,330 β-galactosidase particles (Supplementary Methods); and 5,403 hepatitis B capsid particles from a previously published study7. High-resolution crystal structures are available for all three data sets, and these were used to assess the “true” resolution obtained using refinements based on either gold-standard or conventional FSC procedures (Figure 1). For all three cases, the conventional procedure reported apparently better FSC curves than the gold-standard procedure, but in no case did the gold-standard procedure actually result in a lower resolution map compared to the crystal structure. On the contrary, for the β-galactosidase data the gold-standard procedure yielded a structure that correlated up to higher frequencies with the crystal structure than the conventional procedure, which suffered from severe overfitting and gave rise to strong artefacts in the map. We also note that, in the absence of overfitting, the frequency at which the gold-standard FSC drops below 0.143 is a good indicator of the true resolution of the map (Supplementary Table 1), which is as expected from theory8. Finally, in the limit of very small data sets, division of the data into two halves might affect resolution. However, calculations with subsets of the GroEL particles suggest that this only becomes an issue for data sets that are much smaller than those typically used in cryo-EM reconstructions (Supplementary Figure 4). Figure 1 The prevention of overfitting The principal conclusion is therefore that overfitting of noise using suboptimal FSCs causes worse orientations and leads to a worse structure. In contrast, the use of gold-standard FSCs provides a realistic estimate of the true signal, which ultimately leads to a better map. The procedures proposed here are straightforward to implement in existing programs, and their application will eradicate the hazards of overfitting from cryo-EM structure determination procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/nmeth.2115

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Scheres, S. H. W., & Chen, S.
Venue
Nature Methods
Published
2012-07-29
Volume
9
Issue
9
Pages
853-854
ISSN
  • 1548-7091 (ISSN-L)
  • 1548-7105
OpenAlex
W2075824676
Cited by
1,242
References
0
FWCI
26.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.