Decoding protein modifications using top-down mass spectrometry
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Top-down mass spectrometry is an emerging technology which strives to preserve the post-translationally modified forms of proteins present in vivo by measuring them intact, rather than measuring peptides produced from them by proteolysis. The top-down technology is beginning to capture the interest of biologists and mass spectrometrists alike, with a main goal of deciphering interaction networks operative in cellular pathways. Here we outline recent approaches and applications of top-down mass spectrometry as well as an outlook for its future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Top-down approaches can be helpful to evaluate the total modification status on an individual protein [[93], [94], [95], [96]].”
From Protein oxidation - Formation mechanisms, detection and relevance as biomarkers in human diseases (2021) · cites this paper as [97]
In the citing paper
“In contrast, top-down mass spectrometry (MS)-based proteomics analyzes intact proteins and is the most powerful method to comprehensively characterize proteoforms deciphering the PTMs together with sequence variations1–3.”
From A photocleavable surfactant for top-down proteomics (2019) · cites this paper as [2]
In the citing paper
“Subsequently, proteoforms of interest can be fragmented by tandem MS (MS/MS) for sequence characterization and PTM localization (9, 21, 23).”
From Distinct hypertrophic cardiomyopathy genotypes result in convergent sarcomeric proteoform profiles revealed by top-down proteomics (2020) · cites this paper as [21]
In the citing paper
“top-down proteomics allows for direct analysis of intact proteins without digestion, thus providing a “bird’s-eye” view of existing proteoforms (9, 12, 21, 23, 28, 29).”
From Distinct hypertrophic cardiomyopathy genotypes result in convergent sarcomeric proteoform profiles revealed by top-down proteomics (2020) · cites this paper as [21]
In the citing paper
“Unlike genomics, proteomics more precisely reflects cellular responses and disease phenotypes (21, 27, 28).”
From Distinct hypertrophic cardiomyopathy genotypes result in convergent sarcomeric proteoform profiles revealed by top-down proteomics (2020) · cites this paper as [21]
Citations
Cites
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Self-citationThe Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja973655h · Cited by 605
Self-citationChi, A., Huttenhower, C., Geer, L. Y., Coon, J. J., Syka, J. E. P., Bai, D. L., Shabanowitz, J., Burke, D. J., Troyanskaya, O. G., & Hunt, D. F. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607084104 · Cited by 564 · cited 1×
“html">ECD will propel both top-down and middle-down strategies to achieve better protein characterizatio”
BackgroundPeer Reviewed: Top-Down Proteomics
Kelleher, N. L. (2004) · Analytical Chemistry · doi:10.1021/ac0415657 · Cited by 502
Self-citationProteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Protein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
Kelleher, N. L., Zubarev, R. A., Bush, K., Furie, B., Furie, B. C., McLafferty, F. W., & Walsh, C. T. (1999) · Analytical Chemistry · doi:10.1021/ac990684x · Cited by 368
Self-citationExtending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Yates, J. R., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac401484r · Cited by 324
Self-citationOrbitrap Mass Analyzer – Overview and Applications in Proteomics
Scigelova, M., & Makarov, A. (2006) · PROTEOMICS · doi:10.1002/pmic.200600528 · Cited by 288
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Pervasive combinatorial modification of histone H3 in human cells
Garcia, B. A., Pesavento, J. J., Mizzen, C. A., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1052 · Cited by 243
Self-citationPesavento, J. J., Mizzen, C. A., & Kelleher, N. L. (2006) · Analytical Chemistry · doi:10.1021/ac0600050 · Cited by 240
Self-citationInformatics and multiplexing of intact protein identification in bacteria and the archaea
Meng, F., Cargile, B. J., Miller, L. M., Forbes, A. J., Johnson, J. R., & Kelleher, N. L. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-952 · Cited by 208
Self-citationLeDuc, R. D., Taylor, G. K., Kim, Y.-B., Januszyk, T. E., Bynum, L. H., Sola, J. V., Garavelli, J. S., & Kelleher, N. L. (2004) · Nucleic Acids Research · doi:10.1093/nar/gkh447 · Cited by 202 · cited 1×
“The only algorithm available at present for identifying protein forms from tandem mass spectra of intact proteins is ProSigh”
MethodSelf-citationMacek, B., Waanders, L. F., Olsen, J. V., & Mann, M. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500042-mcp200 · Cited by 197
High-resolution tandem FT mass spectrometry above 10 kDa
McLafferty, F. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00047a009 · Cited by 194
Mass Spectrometric Characterization of Human Histone H3: A Bird's Eye View
Thomas, C. E., Kelleher, N. L., & Mizzen, C. A. (2006) · Journal of Proteome Research · doi:10.1021/pr050266a · Cited by 190
Self-citationProcessing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183 · cited 1×
“, top-down mass spectrometry has continued to evolve from focused studies of single protein targets to the study of complex mixtures or even proteome”
BackgroundSelf-citationLong-distance combinatorial linkage between methylation and acetylation on histone H3 N termini
Taverna, S. D., Ueberheide, B. M., Liu, Y., Tackett, A. J., Diaz, R. L., Shabanowitz, J., Chait, B. T., Hunt, D. F., & Allis, C. D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610993104 · Cited by 183 · cited 1×
“html">MS/MS on intact histones or large proteolytic fragments containing many modification”
BackgroundMcLafferty, F. W., Fridriksson, E. K., Horn, D. M., Lewis, M. A., & Zubarev, R. A. (1999) · Science · doi:10.1126/science.284.5418.1289 · Cited by 166
Pesavento, J. J., Kim, Y.-B., Taylor, G. K., & Kelleher, N. L. (2004) · Journal of the American Chemical Society · doi:10.1021/ja039748i · Cited by 159 · cited 1×
“ProSight uses a candidate expansion method referred to as 'shotgun annotation”
MethodSelf-citationPrecise Characterization of Human Histones in the H2A Gene Family by Top Down Mass Spectrometry
Boyne, M. T., Pesavento, J. J., Mizzen, C. A., & Kelleher, N. L. (2006) · Journal of Proteome Research · doi:10.1021/pr050269n · Cited by 158
Self-citationWeb and Database Software for Identification of Intact Proteins Using “Top Down” Mass Spectrometry
Taylor, G. K., Kim, Y.-B., Forbes, A. J., Meng, F., McCarthy, R., & Kelleher, N. L. (2003) · Analytical Chemistry · doi:10.1021/ac0341721 · Cited by 142 · cited 1×
“In fact, the concept of putting PTMs and cSNPs in database”
BackgroundSelf-citationGene-Specific Characterization of Human Histone H2B by Electron Capture Dissociation
Siuti, N., Roth, M. J., Mizzen, C. A., Kelleher, N. L., & Pesavento, J. J. (2006) · Journal of Proteome Research · doi:10.1021/pr050268v · Cited by 112
Self-citationNeusüß, C., Pelzing, M., & Macht, M. (2002) · Electrophoresis · doi:10.1002/1522-2683(200209)23:18<3224::aid-elps3224>3.0.co;2-# · Cited by 110
Self-citationRoth, M. J., Forbes, A. J., Boyne, M. T., Kim, Y. B., Robinson, D. E., & Kelleher, N. L. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500064-mcp200 · Cited by 103
Self-citationGas-Phase Concentration, Purification, and Identification of Whole Proteins from Complex Mixtures
Reid, G. E., Shang, H., Hogan, J. M., Lee, G. U., & McLuckey, S. A. (2002) · Journal of the American Chemical Society · doi:10.1021/ja025966k · Cited by 96 · cited 1×
“html">ETD with previous approaches for charge manipulation of ions from the McLuckey laborator”
MethodMedzihradszky, K. F., Zhang, X., Chalkley, R. J., Guan, S., McFarland, M. A., Chalmers, M. J., Marshall, A. G., Diaz, R., Allis, C. D., & Burlingame, A. L. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400041-mcp200 · Cited by 96
Top-down mass spectrometry of integral membrane proteins
Whitelegge, J. P., Halgand, F., Souda, P., & Zabrouskov, V. (2006) · Expert Review of Proteomics · doi:10.1586/14789450.3.6.585 · Cited by 95 · cited 1×
“In past years, substantial progress has been made in adapting this approach to integral membrane proteins (recently reviewed in ref”
BackgroundChi, A., Bai, D. L., Geer, L. Y., Shabanowitz, J., & Hunt, D. F. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.09.030 · Cited by 91 · cited 1×
“, top-down in a stand-alone ion trap is now a realit”
BackgroundReiber, D. C., Grover, T. A., & Brown, R. S. (1998) · Analytical Chemistry · doi:10.1021/ac971157l · Cited by 91
Cargile, B. J., McLuckey, S. A., & Stephenson, J. L. (2001) · Analytical Chemistry · doi:10.1021/ac000725l · Cited by 86
Chong, B. E., Yan, F., Lubman, D., & Miller, F. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.227 · Cited by 81
Proteomic profiling of intact proteins using WAX-RPLC 2-D separations and FTICR mass spectrometry.
Sharma, S., Simpson, D., Toliċ, N., Jaitly, N., Mayampurath, A., Smith, R. D., & Paša-Tolić, L. (2007) · Journal of Proteome Research · doi:10.1021/pr060354a · Cited by 77
Stepwise Deamidation of Ribonuclease A at Five Sites Determined by Top Down Mass Spectrometry
Zabrouskov, V., Han, X., Welker, E., Zhai, H., Lin, C., van Wijk, K. J., Scheraga, H. A., & McLafferty, F. W. (2005) · Biochemistry · doi:10.1021/bi0517584 · Cited by 77 · cited 1×
“html">MS/MS of intact protein forms facilitates the determination of modifications as they occur in combination, as well as revealing information about PTM hierarchies (such as which PTMs occur first, second, third and so on”
BackgroundNew and automated MSn approaches for top-down identification of modified proteins
Zabrouskov, V., Senko, M. W., Du, Y., LeDuc, R. D., & Kelleher, N. L. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.08.004 · Cited by 77
Self-citationMeng, F., Du, Y., Miller, L. M., Patrie, S. M., Robinson, D. E., & Kelleher, N. L. (2004) · Analytical Chemistry · doi:10.1021/ac0354903 · Cited by 68
Self-citationReid, G. E., Stephenson, J. L., & McLuckey, S. A. (2001) · Analytical Chemistry · doi:10.1021/ac015618l · Cited by 64
Transit Peptide Cleavage Sites of Integral Thylakoid Membrane Proteins
Gómez, S. M., Bil, K. Y., Aguilera, R., Nishio, J. N., Faull, K. F., & Whitelegge, J. P. (2003) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300062-mcp200 · Cited by 64 · cited 1×
“Fifty-eight thylakoid membrane proteins from a plant have been analyzed using these tailored chromatographic method”
MethodPatrie, S. M., Ferguson, J. T., Robinson, D. E., Whipple, D., Rother, M., Metcalf, W. W., & Kelleher, N. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500219-mcp200 · Cited by 62
Self-citationLoo, R. R. O., Cavalcoli, J. D., VanBogelen, R. A., Mitchell, C., Loo, J. A., Moldover, B., & Andrews, P. (2001) · Analytical Chemistry · doi:10.1021/ac0101858 · Cited by 61
Amunugama, R., Hogan, J. M., Newton, K. A., & McLuckey, S. A. (2004) · Analytical Chemistry · doi:10.1021/ac034900k · Cited by 57
Nemeth‐Cawley, J. F., & Rouse, J. C. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.281 · Cited by 50
Johnson, J. R., Meng, F., Forbes, A. J., Cargile, B. J., & Kelleher, N. L. (2002) · Electrophoresis · doi:10.1002/1522-2683(200209)23:18<3217::aid-elps3217>3.0.co;2-k · Cited by 41
Self-citationDoerr, A. (2008) · Nature Methods · doi:10.1038/nmeth1162 · Cited by 40
Kelleher, N. L., Costello, C. A., Begley, T. P., & McLafferty, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00584-z · Cited by 40
Self-citationZhou, F. C., & Johnston, M. V. (2005) · Electrophoresis · doi:10.1002/elps.200410125 · Cited by 31
Zhao, J., Zhu, K., Lubman, D. M., Miller, F. R., Shekhar, M. P. V., Gérard, B., & Barder, T. J. (2006) · PROTEOMICS · doi:10.1002/pmic.200500195 · Cited by 21
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“Some of the benefits of the top-down approach include higher sequence coverage of target proteins (157) and better characterization of the posttranslational modifications (158, 159).”
BackgroundHydrogen exchange mass spectrometry for studying protein structure and dynamics
Konermann, L., Pan, J., & Liu, Y.-H. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00113a · Cited by 838
Mass spectrometry for proteomics
Han, X., Aslanian, A., & Yates, J. R. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.07.024 · Cited by 734
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
“The typical TDP workflow can be viewed as three primary pillars: (a) front-end fractionation of complex mixtures, (b) high-resolution mass spectral data acquisition at precursor and fragment levels, and (c) data processing and database searching/scoring (20).”
MethodSelf-citationAnalytical tools for characterizing biopharmaceuticals and the implications for biosimilars
Berkowitz, S. A., Engen, J. R., Mazzeo, J. R., & Jones, G. B. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3746 · Cited by 529
Metadata
- Authors
- Siuti, N., & Kelleher, N. L.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- ORCID
- Kelleher, Neil L
- Venue
- Nature Methods
- Published
- 2007-09-27
- Volume
- 4
- Issue
- 10
- Pages
- 817-821
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- PMC
- PMC2365886
- OpenAlex
- W2043492633
- Cited by
- 503
- References
- 50
- Citations by year
- 2026: 11 · 2025: 12 · 2024: 12 · 2023: 25 · 2022: 22 · 2021: 16 · 2020: 17 · 2019: 30 · 2018: 32 · 2017: 31 · 2016: 25 · 2015: 32 · 2014: 30 · 2013: 27 · 2012: 32
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Methods (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- David and Lucile Packard Foundation
- Camille and Henry Dreyfus Foundation
- University of Illinois at Urbana-Champaign
- National Institute of General Medical Sciences (R01GM067193, GM 067193)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- top-down mass spectrometry, post-translational modification, top-down proteomics, protein-protein interaction network, cellular pathways, proteomics
- MeSH terms
- Chromatin, Membrane Proteins, Protein Processing, Post-Translational, Mass Spectrometry, Protein Isoforms, Proteomics, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.