The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Quantification of the affinities and kinetics of protein interactions using silicon nanowire biosensors
Open accessAbstract
Monitoring the binding affinities and kinetics of protein interactions is important in clinical diagnostics and drug development because such information is used to identify new therapeutic candidates. Surface plasmon resonance is at present the standard method used for such analysis, but this is limited by low sensitivity and low-throughput analysis. Here, we show that silicon nanowire field-effect transistors can be used as biosensors to measure protein–ligand binding affinities and kinetics with sensitivities down to femtomolar concentrations. Based on this sensing mechanism, we develop an analytical model to calibrate the sensor response and quantify the molecular binding affinities of two representative protein–ligand binding pairs. The rate constant of the association and dissociation of the protein–ligand pair is determined by monitoring the reaction kinetics, demonstrating that silicon nanowire field-effect transistors can be readily used as high-throughput biosensors to quantify protein interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complex networks: structure and dynamics
BOCCALETTI, S., LATORA, V, MORENO, Y., CHAVEZ, M., & HWANG, D. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.009 · Cited by 11,010
Functional Nanoscale Electronic Devices Assembled Using Silicon Nanowire Building Blocks
Cui, Y., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5505.851 · Cited by 3,258
Tian, J., Avalos, A. M., Mao, S.-Y., Chen, B., Senthil, K., Wu, H., Parroche, P., Drabic, S., Golenbock, D., Sirois, C., et al. (2007) · Nature Immunology · doi:10.1038/ni1457 · Cited by 1,372
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Self-citationOptical biosensors in drug discovery
Cooper, M. A. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd838 · Cited by 1,015
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
How do site-specific DNA-binding proteins find their targets?
Halford, S. E. (2004) · Nucleic Acids Research · doi:10.1093/nar/gkh624 · Cited by 886
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Self-citationBiosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Detection Limits for Nanoscale Biosensors
Sheehan, P. E., & Whitman, L. J. (2005) · Nano Letters · doi:10.1021/nl050298x · Cited by 615
Specific Recognition of Cruciform DNA by Nuclear Protein HMG1
Bianchi, M. E., Beltrame, M., & Paonessa, G. (1989) · Science · doi:10.1126/science.2922595 · Cited by 601
Basis for recognition of cisplatin-modified DNA by high-mobility-group proteins
Ohndorf, U.-M., Rould, M. A., He, Q., Pabo, C. O., & Lippard, S. J. (1999) · Nature · doi:10.1038/21460 · Cited by 565
Label-free detection of small-molecule–protein interactions by using nanowire nanosensors
Wang, W. U., Chen, C., Lin, K.-H., Fang, Y., & Lieber, C. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406368102 · Cited by 534
Biosensors in clinical chemistry
D'Orazio, P. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00241-9 · Cited by 524
Specific Binding of Chromosomal Protein HMG1 to DNA Damaged by the Anticancer Drug Cisplatin
Pil, P. M., & Lippard, S. J. (1992) · Science · doi:10.1126/science.1566071 · Cited by 496
Bunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480
Nanotechnologies for biomolecular detection and medical diagnostics
Cheng, M. M.-C., Cuda, G., Bunimovich, Y. L., Gaspari, M., Heath, J. R., Hill, H. D., Mirkin, C. A., Nijdam, A. J., Terracciano, R., Thundat, T., et al. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.01.006 · Cited by 474
A novel role for HMGB1 in TLR9-mediated inflammatory responses to CpG-DNA
Ivanov, S., Dragoi, A.-M., Wang, X., Dallacosta, C., Louten, J., Musco, G., Sitia, G., Yap, G. S., Wan, Y., Biron, C. A., et al. (2007) · Blood · doi:10.1182/blood-2006-09-044776 · Cited by 470
[2] Introduction to avidin-biotin technology
Wilchek, M., & Bayer, E. A. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)84256-g · Cited by 429
Myszka, D. G., He, X., Dembo, M., Morton, T. A., & Goldstein, B. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77549-6 · Cited by 415
Masaki, T. (2002) · Ecological Studies · doi:10.1007/978-4-431-67879-3_6 · Cited by 353
Quantification of protein interactions and solution transport using high-density GMR sensor arrays
Gaster, R. S., Xu, L., Han, S.-J., Wilson, R. J., Hall, D. A., Osterfeld, S. J., Yu, H., & Wang, S. X. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.45 · Cited by 272
Real-Time, Label-Free Detection of Biological Entities Using Nanowire-Based FETs
Curreli, M., Zhang, R., Ishikawa, F. N., Chang, H.-K., Cote, R. J., Zhou, C., & Thompson, M. E. (2008) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2008.2006165 · Cited by 220
Molecular Recognition between Genetically Engineered Streptavidin and Surface-Bound Biotin
Pérez-Luna, V. H., O'Brien, M. J., Opperman, K. A., Hampton, P. D., López, G. P., Klumb, L. A., & Stayton, P. S. (1999) · Journal of the American Chemical Society · doi:10.1021/ja983984p · Cited by 187
Silicon Nanoribbons for Electrical Detection of Biomolecules
Elfström, N., Karlström, A. E., & Linnros, J. (2008) · Nano Letters · doi:10.1021/nl080094r · Cited by 185
A critical evaluation of direct electrical protein detection methods
Bergveld, P. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)85009-l · Cited by 175
A Calibration Method for Nanowire Biosensors to Suppress Device-to-Device Variation
Ishikawa, F. N., Curreli, M., Chang, H.-K., Chen, P.-C., Zhang, R., Côté, R. J., Thompson, M. E., & Zhou, C. (2009) · ACS Nano · doi:10.1021/nn9011384 · Cited by 149
Semiconducting Nanowire Field-Effect Transistor Biomolecular Sensors
Stern, E., Vacic, A., & Reed, M. A. (2008) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2008.2005168 · Cited by 146
Self-citationNature of Full-Length HMGB1 Binding to Cisplatin-Modified DNA
Jung, Y., & Lippard, S. J. (2003) · Biochemistry · doi:10.1021/bi026972w · Cited by 113
Challenges in the use of 1D nanostructures for on-chip biosensing and diagnostics: A review
Balasubramanian, K. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.041 · Cited by 93
DNA binding to proteolytically activated TLR9 is sequence‐independent and enhanced by DNA curvature
Li, Y., Berke, I. C., & Modis, Y. (2011) · The EMBO Journal · doi:10.1038/emboj.2011.441 · Cited by 71
Self-citationTang, Y., Mernaugh, R. L., & Zeng, X. (2006) · Analytical Chemistry · doi:10.1021/ac051868g · Cited by 69
Lee, B. Y., Sung, M. G., Lee, J., Baik, K. Y., Kwon, Y., Lee, M.-S., & Hong, S. (2011) · ACS Nano · doi:10.1021/nn103056s · Cited by 64
Quantifying signal changes in nano-wire based biosensors
Vico, L. D., Sørensen, M. H., Iversen, L., Rogers, D. M., Sørensen, B. S., Brandbyge, M., Nygård, J., Martinez, K. L., & Jensen, J. H. (2010) · Nanoscale · doi:10.1039/c0nr00442a · Cited by 42
Cited by
Single-molecule nucleic acid interactions monitored on a label-free microcavity biosensor platform
Baaske, M. D., Foreman, M. R., & Vollmer, F. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.180 · Cited by 559
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Artificial sensing intelligence with silicon nanowires for ultraselective detection in the gas phase
Wang, B., Cancilla, J. C., Torrecilla, J. S., & Haick, H. (2014) · Nano Letters · doi:10.1021/nl404335p · Cited by 236
Metadata
- Authors
- Duan, X., Li, Y., Rajan, N. K., Routenberg, D. A., Modis, Y., & Reed, M. A.
- Venue
- Nature Nanotechnology
- Published
- 2012-05-27
- Volume
- 7
- Issue
- 6
- Pages
- 401-407
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2058957939
- Cited by
- 366
- References
- 35
- FWCI
- 16.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.