Thin-film PMUTs: a review of over 40 years of research
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Thin-film PMUTs have been important research topics among microultrasound experts, and a concise review on their research progress is reported herein. Through rigorous surveying, scrutinization, and perception, it has been determined that the work in this field began nearly 44 years ago with the primitive development of functional piezoelectric thin-film materials. To date, there are three major companies commercializing thin-film PMUTs on a bulk scale. This commercialization illustrates the extensive contributions made by more than 70 different centers, research institutes, and agencies across 4 different continents regarding the vast development of these devices’ design, manufacturing, and function. This review covers these important contributions in a short yet comprehensive manner; in particular, this paper educates readers about the global PMUT outlook, their governing design principles, their manufacturing methods, nonconventional yet useful PMUT designs, and category-wise applications. Crucial comparison charts of thin-film piezoelectric material used in PMUTs, and their categorically targeted applications are depicted and discussed to enlighten any MEMS designer who plans to work with PMUTs. Moreover, each relevant section features clear future predictions based on the author’s past knowledge and expertise in this field of research and on the findings of a careful literature survey. In short, this review is a one-stop time-efficient guide for anyone interested in learning about these small devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrastructural Characterization of the Lower Motor System in a Mouse Model of Krabbe Disease
Cappello, V., Marchetti, L., Parlanti, P., Landi, S., Tonazzini, I., Cecchini, M., Piazza, V., & Gemmi, M. (2016) · Scientific Reports · doi:10.1038/s41598-016-0001-8 · Cited by 13,097
Standards and figure-of-merits for quantifying the performance of triboelectric nanogenerators
Zi, Y., Niu, S., Wang, J., Wen, Z., Tang, W., & Wang, Z. L. (2015) · Nature Communications · doi:10.1038/ncomms9376 · Cited by 897
Wen, Z., Yeh, M.-H., Guo, H., Wang, J., Zi, Y., Xu, W., Deng, J., Zhu, L., Wang, X., Hu, C., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600097 · Cited by 854
Nanopatterned Textile-Based Wearable Triboelectric Nanogenerator
Seung, W., Gupta, M. K., Lee, K. Y., Shin, K.-S., Lee, J.-H., Kim, T. Y., Kim, S., Lin, J., Kim, J. H., & Kim, S.-W. (2015) · ACS Nano · doi:10.1021/nn507221f · Cited by 714
Self-citationChoi, M., Choi, D., Jin, M., Kim, I., Kim, S., Choi, J., Lee, S. Y., Kim, J. M., & Kim, S. (2009) · Advanced Materials · doi:10.1002/adma.200803605 · Cited by 439
Dubois, M.-A., & Muralt, P. (1999) · Applied Physics Letters · doi:10.1063/1.124055 · Cited by 436
Lee, J., Yoon, H., Kim, T. Y., Gupta, M. K., Lee, J. H., Seung, W., Ryu, H., & Kim, S. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500856 · Cited by 426
Self-citationLedermann, N., Muralt, P., Baborowski, J., Gentil, S., Mukati, K., Cantoni, M., Seifert, A., & Setter, N. (2003) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(03)00090-6 · Cited by 395
Qiu, Y., Gigliotti, J., Wallace, M., Griggio, F., Demore, C., Cochran, S., & Trolier-McKinstry, S. (2015) · Sensors · doi:10.3390/s150408020 · Cited by 395
Piezoelectric Thin Films for Sensors, Actuators, and Energy Harvesting
Muralt, P., Polcawich, R. G., & Trolier-McKinstry, S. (2009) · MRS Bulletin · doi:10.1557/mrs2009.177 · Cited by 366 · cited 3×
“In 1990, Udayakumar et al.7 used sol-gel (PZT) thin films for flexural wave applications, followed by Muralt et al., who demonstrated the effects of the membrane structure and electrical parameters of thin-film PZT on PMUT response in 19968.”
MethodReview of piezoelectric micromachined ultrasonic transducers and their applications
Jung, J., Lee, W., Kang, W., Shin, E., Ryu, J., & Choi, H. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa851b · Cited by 340
Micromachined high frequency ferroelectric sonar transducers
Bernstein, J. J., Finberg, S. L., Houston, K., Niles, L. C., Chen, H. D., Cross, L. E., Li, K. K., & Udayakumar, K. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.655620 · Cited by 261
Development of piezoelectric micromachined ultrasonic transducers
Akasheh, F., Myers, T., Fraser, J. D., Bose, S., & Bandyopadhyay, A. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.022 · Cited by 253
Lu, Y., Tang, H., Fung, S., Wang, Q., Tsai, J. M., Daneman, M., Boser, B. E., & Horsley, D. A. (2015) · Applied Physics Letters · doi:10.1063/1.4922915 · Cited by 244 · cited 1×
“In 2015, Lu et al.(24) demonstrated a system-on-chip fingerprint sensor, which is one of the most important applications with relevance to consumer electronics.”
BackgroundPiezoelectric actuation of PZT thin-film diaphragms at static and resonant conditions
Muralt, P., Kholkin, A. L., Köhli, M., & Maeder, T. (1996) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(96)01139-9 · Cited by 212
Shi, Q., Wang, T., & Lee, C. (2016) · Scientific Reports · doi:10.1038/srep24946 · Cited by 210 · cited 5×
“Shi et al.102 made an AI-enabled soft robotic perception system with PMUT-based auto positioning and TENG to achieve appropriate positioning of randomly distributed objects (Fig.”
BackgroundMethodInfluentialSelf-citationIn-Air Rangefinding With an AlN Piezoelectric Micromachined Ultrasound Transducer
Przybyla, R. J., Shelton, S. E., Guedes, A., Izyumin, I. I., Kline, M. H., Horsley, D. A., & Boser, B. E. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157490 · Cited by 198
Lu, Y., & Horsley, D. A. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2387154 · Cited by 194
Advances in Capacitive Micromachined Ultrasonic Transducers
Brenner, K., Ergun, A., Firouzi, K., Rasmussen, M., Stedman, Q., & Khuri–Yakub, B. (2019) · Micromachines · doi:10.3390/mi10020152 · Cited by 169
Soft Robotic Perception System with Ultrasonic Auto-Positioning and Multimodal Sensory Intelligence
Shi, Q., Sun, Z., Le, X., Xie, J., & Lee, C. (2023) · ACS Nano · doi:10.1021/acsnano.2c12592 · Cited by 157 · cited 4×
“Shi et al.102 made an AI-enabled soft robotic perception system with PMUT-based auto positioning and TENG to achieve appropriate positioning of randomly distributed objects (Fig.”
MethodInfluentialSelf-citationCMOS-compatible AlN piezoelectric micromachined ultrasonic transducers
Shelton, S. E., Chan, M.-L., Park, H., Horsley, D. A., Boser, B. E., Izyumin, I. I., Przybyla, R. J., Frey, T. J., Judy, M. W., Nunan, K., et al. (2009) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2009.5441602 · Cited by 134
In vivo real-time 3-D intracardiac echo using PMUT arrays
Dausch, D. E., Gilchrist, K. H., Carlson, J. B., Hall, S. D., Castellucci, J. B., & von Ramm, O. T. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006452 · Cited by 118 · cited 2×
“In the first direction, Dausch et al.(92) fabricated two 256- and 512-element arrays through silicon vias to make an intracardiac catheter that captured a B-mode image in vivo from a porcine model (Fig.”
MethodSun, C., Shi, Q., Hasan, D. M. N., Yazici, M. S., Zhu, M., Ma, Y., Dong, B., Liu, Y., & Lee, C. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.096 · Cited by 117 · cited 6×
“Sun et al. reported a PMUT array sticker (Fig.”
BackgroundMethodInfluentialSelf-citationTheory and operation of 2-D array piezoelectric micromachined ultrasound transducers
Dausch, D. E., Castellucci, J. B., Chou, D. R., & von Ramm, O. T. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.956 · Cited by 109
Airborne Piezoelectric Micromachined Ultrasonic Transducers for Long-Range Detection
Luo, G.-L., Kusano, Y., & Horsley, D. A. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3037298 · Cited by 100
Wang, T., & Lee, C. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2472958 · Cited by 92
Self-citationPop, F., Herrera, B., & Rinaldi, M. (2022) · Nature Communications · doi:10.1038/s41467-022-29355-9 · Cited by 88 · cited 5×
“Pop et al. created a bioheating platform76 with a 5 ×10 PMUT phased array and demonstrated a 4 °C increase in the relative temperature after 10 s (Fig.”
BackgroundInfluentialMicromachined piezoelectric ultrasonic transducer with ultra-wide frequency bandwidth
Wang, T., Kobayashi, T., & Lee, C. (2015) · Applied Physics Letters · doi:10.1063/1.4905441 · Cited by 87
Self-citationA Piezoelectric Micromachined Ultrasonic Transducer Using Piston-Like Membrane Motion
Wang, T., Sawada, R., & Lee, C. (2015) · IEEE Electron Device Letters · doi:10.1109/led.2015.2459075 · Cited by 82
Self-citationA Photoacoustic Imaging Device Using Piezoelectric Micromachined Ultrasound Transducers (PMUTs)
Dangi, A., Cheng, C., Agrawal, S., Tiwari, S., Datta, G. R., Benoit, R. R., Pratap, R., Trolier-McKinstry, S. E., & Kothapalli, S. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2956463 · Cited by 81 · cited 2×
“In PA imaging, Dangi et al.81,82 combined a PMUT array with a pulsed light source in a single device that could image a custommade phantom with embedded lead targets, as shown in Fig.”
MethodEffects of DC Bias Tuning on Air-Coupled PZT Piezoelectric Micromachined Ultrasonic Transducers
Kusano, Y., Wang, Q., Luo, G.-L., Lu, Y., Rudy, R. Q., Polcawich, R. G., & Horsley, D. A. (2018) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2797684 · Cited by 72
Highly responsive curved aluminum nitride pMUT
Akhbari, S., Sammoura, F., Shelton, S. E., Chen, Y., Horsley, D. A., & Lin, L. (2014) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2014.6765589 · Cited by 71
Beyond fundamental resonance mode: high-order multi-band ALN PMUT for in vivo photoacoustic imaging
Cai, J., Wang, Y., Jiang, D., Zhang, S., Gu, Y. A., Lou, L., Gao, F., & Wu, T. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00426-7 · Cited by 66
Neuromorphic object localization using resistive memories and ultrasonic transducers
Moro, F., Hardy, E., Fain, B., Dalgaty, T., Clémençon, P., Prà, A. D., Esmanhotto, E., Castellani, N., Blard, F., Gardien, F., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-31157-y · Cited by 62
Lu, Y., Heidari, A., Shelton, S. E., Guedes, A. F. S., & Horsley, D. A. (2014) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2014.6765748 · Cited by 58
Shi, Q., Wang, T., Kobayashi, T., & Lee, C. (2016) · Applied Physics Letters · doi:10.1063/1.4948973 · Cited by 54
Self-citationFluid Density Sensing Using Piezoelectric Micromachined Ultrasound Transducers
Roy, K., Gupta, H., Shastri, V., Dangi, A., Antony Jeyaseelan, A., Dutta, S., & Pratap, R. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2936469 · Cited by 54
Self-citationWang, M., Zhou, Y., & Randles, A. B. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2577038 · Cited by 52
A PMUT Integrated Microfluidic System for Fluid Density Sensing
Roy, K., Kalyan, K., Ashok, A., Shastri, V., Antony Jeyaseelan, A., Mandal, A., & Pratap, R. (2021) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2021.3091651 · Cited by 47 · cited 4×
“In 2021, Roy et al.30 developed a microfluidic integrated platform with PMUTs and demonstrated fluid density sensing, followed by applying PMUTs for high-data rate intrabody communication by Pop et al. for the first time in 202231.”
MethodInfluentialSelf-citationBroadband ring-shaped PMUTS based on an acoustically induced resonance
Eovino, B. E., Akhbari, S., & Lin, L. (2017) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2017.7863627 · Cited by 44
Perçin, G., & Khuri-Yakub, B. T. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1002457 · Cited by 40
Thin Film PZT-Based PMUT Arrays for Deterministic Particle Manipulation
Cheng, C., Dangi, A., Ren, L., Tiwari, S., Benoit, R. R., Qiu, Y., Lay, H. S., Agrawal, S., Pratap, R., Kothapalli, S., et al. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2926211 · Cited by 37 · cited 2×
“In acoustofluidics, Cheng et al.77 developed confined PMUT arrays to trap and manipulate 4-μm silica beads using unipolar excitation (Fig.”
BackgroundMEMS ultrasonic transducers for safe, low-power and portable eye-blinking monitoring
Sun, S., Wang, J., Zhang, M., Yuan, N., Ma, D., Yuan, Y., Niu, P., Rong, Z., Wang, Z., & Pang, W. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00396-w · Cited by 37
Fluid Density Sensing Using PMUTs
Roy, K., Gupta, H., Shastri, V., Dangi, A., & Pratap, R. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8589662 · Cited by 31
Self-citationBody Conformal Linear Ultrasound Array for Combined Ultrasound and Photoacoustic Imaging
Roy, K., Agrawal, S., Dangi, A., Liu, T., Chen, H., Jackson, T. N., Pratap, R., & Kothapalli, S. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251458 · Cited by 30
Self-citation32 Element Piezoelectric Micromachined Ultrasound Transducer (PMUT) Phased Array for Neuromodulation
Tipsawat, P., Ilham, S. J., Yang, J. I., Kashani, Z., Kiani, M., & Trolier-McKinstry, S. E. (2022) · IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/ojuffc.2022.3196823 · Cited by 27 · cited 2×
“Regarding therapeutics, Tipsawat et al.73 developed a 32-element phased array PMUT with beam steering by using Nb-doped PZT for neuromodulation (Fig.”
BackgroundSadeghpour, S., Lips, B., Kraft, M. D., & Puers, R. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.2972729 · Cited by 26 · cited 3×
“Sadeghpour et al. created bendable PMUT arrays (Fig.”
BackgroundInfluentialZero-Power Ultrasonic Wakeup Receiver Based on MEMS Switches for Implantable Medical Devices
Pop, F., Calisgan, S. D., Herrera, B., Risso, A., Kang, S., Rajaram, V., Qian, Z., & Rinaldi, M. (2022) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2022.3140406 · Cited by 24 · cited 5×
“Pop et al. created a bioheating platform76 with a 5 ×10 PMUT phased array and demonstrated a 4 °C increase in the relative temperature after 10 s (Fig.”
BackgroundInfluentialFully Flexible PMUT Based on Polymer Materials and Stress Compensation by Adaptive Frequency Driving
Jeong, Y., Genoe, J., Gijsenbergh, P., Segers, J., Heremans, P. L., & Cheyns, D. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3043052 · Cited by 21 · cited 2×
“In 2020, Jeong et al.29 developed a fabrication flow for flexible thin-film PMUTs, which has relevance in wearable medical applications.”
BackgroundA Single Cell PMUT as a Bio-Fluid Density Sensor
Roy, K., Mandal, A., Ashok, A., Gupta, H., Shastri, V., & Pratap, R. (2020) · IEEE International Ultrasonics Symposium · doi:10.1109/ius46767.2020.9251809 · Cited by 21
Self-citationLee, W., Yoo, S., Jung, J., Kang, W., Wang, W., Moon, C., & Choi, H. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0228-6 · Cited by 19
Rozen, O., Block, S. T., Shelton, S. E., & Horsley, D. A. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7181012 · Cited by 13
Piezoelectric micro-machined ultrasonic transducer (pMUT) for energy harvesting
Dogheche, K., Cavallier, B., Delobelle, P., Hirsinger, L., Ballandras, S., Cattan, É., Rémiens, D., Marzencki, M., Charlot, B., & Basrour, S. (2006) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2005.1603005 · Cited by 11 · cited 2×
“Cavallier et al.(14) demonstrated energy harvesting applications using PMUTs in 2005.”
BackgroundConcentric PMUT Arrays for Focused Ultrasound and High Intensity Applications
Eovino, B. E., Liang, Y., & Lin, L. (2019) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2019.8870884 · Cited by 10
Cited by
Li, D., Yadav, A., Zhou, H., Roy, K., Thanasekaran, P., & Lee, C. (2024) · Global Challenges · doi:10.1002/gch2.202300244 · Cited by 437
Self-citation
Metadata
- Authors
- Roy, K., Lee, J. E.-Y., & Lee, C.
- Venue
- Microsystems & Nanoengineering
- Published
- 2023-07-21
- Volume
- 9
- Issue
- 1
- Pages
- 95-95
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W4385067568
- Cited by
- 180
- References
- 54
- FWCI
- 13.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.