CoChat

Modeling, Fabrication, and Characterization of Piezoelectric Micromachined Ultrasonic Transducer Arrays Based on Cavity SOI Wafers

Lu, Yipeng, Horsley, David A. · 2015 · Journal of Microelectromechanical Systems
Cited by 194

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

This paper presents high fill-factor piezoelectric micromachined ultrasonic transducer (PMUT) arrays fabricated via a novel process using cavity SOI wafers. The simple three-mask fabrication process enables smaller diameter PMUTs (25 μm) and finer pitch than previous processes requiring through-wafer etching. PMUTs were fabricated with diameters from 25 to 50 μm, resulting in center frequencies from 13 to 55 MHz in air. Two types of devices, having different piezoelectric layers, lead zirconium titanate (PZT), and aluminum nitride (AlN), were fabricated and characterized. Comparing 50-μm diameter devices, the PZT PMUTs show large dynamic displacement sensitivity of 316 nm/V at 11 MHz in air, which is ~20x higher than that of the AlN PMUTs. Electrical impedance measurements of the PZT PMUTs show high electromechanical coupling k2t= 12.5% and 50-Ω electrical impedance that is well-matched to typical interface circuits. Immersion tests were conducted on PZT PMUT arrays. The fluid-immersed acoustic pressure generated by an unfocused 9 × 9 array of 40-μm diameter, 10-MHz PZT PMUTs, measured with a needle hydrophone 1.2 mm away from the array, was 58 kPa with a 25 Vpp input. Beam forming based on electronic phase control produced a narrow, 150-μm diameter, focused beam over a depth of focus >0.2 mm and increased the pressure to 450 kPa with 18 Vpp input.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jmems.2014.2387154

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 194

Metadata

Authors
Lu, Y., & Horsley, D. A.
Venue
Journal of Microelectromechanical Systems
Published
2015-08
Volume
24
Issue
4
Pages
1142-1149
ISSN
  • 1057-7157 (ISSN-L)
  • 1941-0158
OpenAlex
W2019123650
Cited by
194
References
22
FWCI
14.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modeling, Fabrication, and Characterization of Piezoelectric Micromachined Ultrasonic Transducer Arrays Based on Cavity SOI Wafers. https://app.cochat.ai/papers/10.1109/jmems.2014.2387154
The paper
Lu, Y., & Horsley, D. A. (2015). Modeling, Fabrication, and Characterization of Piezoelectric Micromachined Ultrasonic Transducer Arrays Based on Cavity SOI Wafers. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2014.2387154

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.