CoChat

Noninvasive sub-organ ultrasound stimulation for targeted neuromodulation

Open access
Cotero, Victoria, Fan, Ying, Tsaava, Tea, Kressel, Adam M., Hancu, Ileana, Fitzgerald, Paul, Wallace, Kirk, Kaanumalle, Sireesha, Graf, John, Rigby, Wayne, Kao, Tzu-Jen, Roberts, Jeanette, Bhushan, Chitresh, Joel, Suresh, Coleman, Thomas R., Zanos, Stavros, Tracey, Kevin J., Ashe, Jeffrey, Chavan, Sangeeta S., Puleo, Christopher · 2019 · Nature Communications
Cited by 216

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Tools for noninvasively modulating neural signaling in peripheral organs will advance the study of nerves and their effect on homeostasis and disease. Herein, we demonstrate a noninvasive method to modulate specific signaling pathways within organs using ultrasound (U/S). U/S is first applied to spleen to modulate the cholinergic anti-inflammatory pathway (CAP), and US stimulation is shown to reduce cytokine response to endotoxin to the same levels as implant-based vagus nerve stimulation (VNS). Next, hepatic U/S stimulation is shown to modulate pathways that regulate blood glucose and is as effective as VNS in suppressing the hyperglycemic effect of endotoxin exposure. This response to hepatic U/S is only found when targeting specific sub-organ locations known to contain glucose sensory neurons, and both molecular (i.e. neurotransmitter concentration and cFOS expression) and neuroimaging results indicate US induced signaling to metabolism-related hypothalamic sub-nuclei. These data demonstrate that U/S stimulation within organs provides a new method for site-selective neuromodulation to regulate specific physiological functions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-019-08750-9

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 216

Metadata

Authors
Cotero, V., Fan, Y., Tsaava, T., Kressel, A. M., Hancu, I., Fitzgerald, P., Wallace, K., Kaanumalle, S., Graf, J., Rigby, W., Kao, T.-J., Roberts, J., Bhushan, C., Joel, S., Coleman, T. R., Zanos, S., Tracey, K. J., Ashe, J., Chavan, S. S., & Puleo, C.
Venue
Nature Communications
Published
2019-03-12
Volume
10
Issue
1
Pages
952-952
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2921881258
Cited by
216
References
15
FWCI
9.53
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive sub-organ ultrasound stimulation for targeted neuromodulation. https://app.cochat.ai/papers/10.1038/s41467-019-08750-9
The paper
Cotero, V., Fan, Y., Tsaava, T., Kressel, A. M., Hancu, I., Fitzgerald, P., Wallace, K., Kaanumalle, S., Graf, J., Rigby, W., Kao, T.-J., Roberts, J., Bhushan, C., Joel, S., Coleman, T. R., Zanos, S., Tracey, K. J., Ashe, J., Chavan, S. S., & Puleo, C. (2019). Noninvasive sub-organ ultrasound stimulation for targeted neuromodulation. Nature Communications. https://doi.org/10.1038/s41467-019-08750-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.