A H2O2-activatable nanoprobe for diagnosing interstitial cystitis and liver ischemia-reperfusion injury via multispectral optoacoustic tomography and NIR-II fluorescent imaging
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Developing high-quality NIR-II fluorophores (emission in 1000–1700 nm) for in vivo imaging is of great significance. Benzothiadiazole-core fluorophores are an important class of NIR-II dyes, yet ongoing limitations such as aggregation-caused quenching in aqueous milieu and non-activatable response are still major obstacles for their biological applications. Here, we devise an activatable nanoprobe to address these limitations. A molecular probe named BTPE-NO 2 is synthesized by linking a benzothiadiazole core with two tetraphenylene groups serving as hydrophobic molecular rotors, followed by incorporating two nitrophenyloxoacetamide units at both ends of the core as recognition moieties and fluorescence quenchers. An FDA-approved amphiphilic polymer Pluronic F127 is then employed to encapsulate the molecular BTPE-NO 2 to render the nanoprobe BTPE-NO 2@F127. The pathological levels of H 2 O 2 in the disease sites cleave the nitrophenyloxoacetamide groups and activate the probe, thereby generating strong fluorescent emission (950~1200 nm) and ultrasound signal for multi-mode imaging of inflammatory diseases. The nanoprobe can therefore function as a robust tool for detecting and imaging the disease sites with NIR-II fluorescent and multispectral optoacoustic tomography (MSOT) imaging. Moreover, the three-dimensional MSOT images can be obtained for visualizing and locating the disease foci.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778 · cited 1×
“…including low light scattering and weak auto fl uorescence in tissues, which enables real-time imaging at much deeper depth with higher resolution in organism and could be employed for more accurate diagnosis of disease, monitoring of therapy course and understanding disease development 1 – 4 .”
Diagnosis and Treatment of Interstitial Cystitis/Bladder Pain Syndrome: AUA Guideline Amendment
Hanno, P. M., Erickson, D., Moldwin, R., & Faraday, M. M. (2015) · Journal of Urology · doi:10.1016/j.juro.2015.01.086 · Cited by 692 · cited 1×
“It is hard to diagnose, as currently no speci fi c clinical testing exists to diagnose the disease and hence it is often diagnosed upon other conditions being ruled out 45 .”
Molecular Motion in Aggregates: Manipulating TICT for Boosting Photothermal Theranostics
Liu, S., Zhou, X., Zhang, H., Ou, H., Lam, J. W. Y., Liu, Y., Shi, L., Ding, D., & Tang, B. Z. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b13889 · Cited by 647
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Anti-quenching NIR-II molecular fluorophores for in vivo high-contrast imaging and pH sensing
Wang, S., Fan, Y., Li, D., Sun, C., Lei, Z., Lu, L., Wang, T., & Zhang, F. (2019) · Nature Communications · doi:10.1038/s41467-019-09043-x · Cited by 510
Li, Y., Cai, Z., Liu, S., Zhang, H., Wong, S. T. H., Lam, J. W. Y., Kwok, R. T. K., Qian, J., & Tang, B. Z. (2020) · Nature Communications · doi:10.1038/s41467-020-15095-1 · Cited by 464
Qi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418
Novel NIR-II organic fluorophores for bioimaging beyond 1550 nm
Li, Y., Liu, Y., Li, Q., Zeng, X., Tian, T., Zhou, W., Cui, Y., Wang, X., Cheng, X., Ding, Q., et al. (2020) · Chemical Science · doi:10.1039/c9sc06567a · Cited by 177
Wu, W., Yang, Y., Yang, Y., Yang, Y., Zhang, K., Guo, L., Ge, H., Chen, X., Liu, J., & Feng, H. (2019) · Small · doi:10.1002/smll.201805549 · Cited by 122 · cited 1×
“Among the NIR-II organic fl uorescent dyes, those based on benzothiadiazole backbone have aroused extensive attention because of the ease of extending their fl uorescent emission into the NIR-II range, excellent photostability and large stoke shifts 5 – 8 .”
Cited by
Fluorescent Probes for Disease Diagnosis
Wang, X., Ding, Q., Groleau, R. R., Wu, L., Mao, Y., Che, F., Kotova, O., Scanlan, E. M., Lewis, S. E., Li, P., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00776 · Cited by 543
Aggregation-Induced Emission (AIE), Life and Health
Wang, H., Li, Q., Alam, P., Bai, H., Bhalla, V., Bryce, M. R., Cao, M., Chen, C., Chen, S., Chen, X., et al. (2023) · ACS Nano · doi:10.1021/acsnano.3c03925 · Cited by 385
Self-citationChen, J., Chen, L., Zeng, F., & Wu, S. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c01241 · Cited by 50
Self-citationNIR-II bioimaging of small molecule fluorophores: From basic research to clinical applications
Li, C., Guan, X., Zhang, X., Zhou, D., Son, S., Xu, Y., Deng, M., Guo, Z., Sun, Y., & Kim, J. S. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114620 · Cited by 49
Activatable Molecular Probes With Clinical Promise for NIR‐II Fluorescent Imaging
Chen, Z., Zhou, Y., Li, L., Ma, W., Li, Y., & Yang, Z. (2025) · Small · doi:10.1002/smll.202411787 · Cited by 26
Metadata
- Authors
- Chen, J., Chen, L., Wu, Y., Fang, Y., Zeng, F., Wu, S., & Zhao, Y.
- Venue
- Nature Communications
- Published
- 2021-11-25
- Volume
- 12
- Issue
- 1
- Pages
- 6870-6870
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3217482763
- Cited by
- 140
- References
- 12
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A H2O2-activatable nanoprobe for diagnosing interstitial cystitis and liver ischemia-reperfusion injury via multispectral optoacoustic tomography and NIR-II fluorescent imaging. https://app.cochat.ai/papers/10.1038/s41467-021-27233-4
- The paper
- Chen, J., Chen, L., Wu, Y., Fang, Y., Zeng, F., Wu, S., & Zhao, Y. (2021). A H2O2-activatable nanoprobe for diagnosing interstitial cystitis and liver ischemia-reperfusion injury via multispectral optoacoustic tomography and NIR-II fluorescent imaging. Nature Communications. https://doi.org/10.1038/s41467-021-27233-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.