CoChat

Flexible, scalable, high channel count stereo-electrode for recording in the human brain

Open access
Lee, Keundong, Paulk, Angelique C., Ro, Yun Goo, Cleary, Daniel R., Tonsfeldt, Karen J., Kfir, Yoav, Pezaris, John S., Tchoe, Youngbin, Lee, Jihwan, Bourhis, Andrew M., Vatsyayan, Ritwik, Martin, Joel R., Russman, Samantha M., Yang, Jimmy C., Baohan, Amy, Richardson, R. Mark, Williams, Ziv M., Fried, Shelley I., Hoi Sang, U., Raslan, Ahmed M., Ben-Haim, Sharona, Halgren, Eric, Cash, Sydney S., Dayeh, Shadi. A. · 2024 · Nature Communications
Cited by 64

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Over the past decade, stereotactically placed electrodes have become the gold standard for deep brain recording and stimulation for a wide variety of neurological and psychiatric diseases. Current electrodes, however, are limited in their spatial resolution and ability to record from small populations of neurons, let alone individual neurons. Here, we report on an innovative, customizable, monolithically integrated human-grade flexible depth electrode capable of recording from up to 128 channels and able to record at a depth of 10 cm in brain tissue. This thin, stylet-guided depth electrode is capable of recording local field potentials and single unit neuronal activity (action potentials), validated across species. This device represents an advance in manufacturing and design approaches which extends the capabilities of a mainstay technology in clinical neurology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-023-43727-9

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 64

Metadata

Authors
Lee, K., Paulk, A. C., Ro, Y. G., Cleary, D. R., Tonsfeldt, K. J., Kfir, Y., Pezaris, J. S., Tchoe, Y., Lee, J., Bourhis, A. M., Vatsyayan, R., Martin, J. R., Russman, S. M., Yang, J. C., Baohan, A., Richardson, R. M., Williams, Z. M., Fried, S. I., Hoi Sang, U., Raslan, A. M., Ben-Haim, S., Halgren, E., Cash, S. S., & Dayeh, S. A.
Venue
Nature Communications
Published
2024-01-17
Volume
15
Issue
1
Pages
218-218
ISSN
2041-1723 (ISSN-L)
OpenAlex
W4390954508
Cited by
64
References
13
FWCI
9.94
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flexible, scalable, high channel count stereo-electrode for recording in the human brain. https://app.cochat.ai/papers/10.1038/s41467-023-43727-9
The paper
Lee, K., Paulk, A. C., Ro, Y. G., Cleary, D. R., Tonsfeldt, K. J., Kfir, Y., Pezaris, J. S., Tchoe, Y., Lee, J., Bourhis, A. M., Vatsyayan, R., Martin, J. R., Russman, S. M., Yang, J. C., Baohan, A., Richardson, R. M., Williams, Z. M., Fried, S. I., Hoi Sang, U., . . . Dayeh, S. A. (2024). Flexible, scalable, high channel count stereo-electrode for recording in the human brain. Nature Communications. https://doi.org/10.1038/s41467-023-43727-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.