Microneedle-based device for the one-step painless collection of capillary blood samples
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
Self-citationMicroneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708
Effect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701
The Cutaneous Microcirculation
Braverman, I. M. (2000) · Journal of Investigative Dermatology Symposium Proceedings · doi:10.1046/j.1087-0024.2000.00010.x · Cited by 486
(1995) · PubMed · Cited by 375
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330
A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function Testing
Pollock, N. R., Rolland, J. P., Kumar, S., Beattie, P. D., Jain, S., Noubary, F., Wong, V. L., Pohlmann, R. A., Ryan, U. S., & Whitesides, G. M. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003981 · Cited by 326
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Windich-Biermeier, A., Sjoberg, I., Dale, J. C., Eshelman, D., & Guzzetta, C. E. (2007) · Journal of Pediatric Oncology Nursing · doi:10.1177/1043454206296018 · Cited by 243
Microneedles for Transdermal Biosensing: Current Picture and Future Direction
Ventrelli, L., Marsilio Strambini, L., & Barillaro, G. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500450 · Cited by 235
Improved piercing of microneedle arrays in dermatomed human skin by an impact insertion method
Verbaan, F. J., Bal, S. M., van den Berg, D. J., Dijksman, J. A., van Hecke, M., Verpoorten, H., van den Berg, A., Luttge, R., & Bouwstra, J. A. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.02.009 · Cited by 233
Fear of needles and vasovagal reactions among phlebotomy patients
Deacon, B., & Abramowitz, J. (2006) · Journal of Anxiety Disorders · doi:10.1016/j.janxdis.2006.01.004 · Cited by 196
Coulman, S. A., Birchall, J. C., Alex, A., Pearton, M., Höfer, B., O’Mahony, C., Drexler, W., & Považay, B. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0167-x · Cited by 139
Li, C. G., Joung, H., Noh, H., Song, M.-B., Kim, M., & Jung, H. (2015) · Lab on a Chip · doi:10.1039/c5lc00669d · Cited by 138
An optimized hollow microneedle for minimally invasive blood extraction
Li, C. G., Lee, C. Y., Lee, K., & Jung, H. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9683-2 · Cited by 132
Crichton, M. L., Ansaldo, A. B., Chen, X., Prow, T. W., Fernando, G. J. P., & Kendall, M. A. F. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.022 · Cited by 131
Rapid Intradermal Delivery of Liquid Formulations Using a Hollow Microstructured Array
Burton, S. A., Ng, C.-Y., Simmers, R., Moeckly, C., Brandwein, D., Gilbert, T., Johnson, N., Brown, K., Alston, T., Prochnow, G., et al. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0177-8 · Cited by 130
Evidence-Based Point-of-Care Diagnostics: Current Status and Emerging Technologies
Chan, C. P. Y., Mak, W. C., Cheung, K. Y., Sin, K. K., Yu, C. M., Rainer, T. H., & Renneberg, R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092641 · Cited by 107
Simple Paper-Based Test for Measuring Blood Hemoglobin Concentration in Resource-Limited Settings
Yang, X., Piety, N. Z., Vignes, S. M., Benton, M. S., Kanter, J., & Shevkoplyas, S. S. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.204701 · Cited by 103
A Reappraisal of the 21-Day Cumulative Irritation Test in Man
Richard, S., & James, P. B. (1982) · Journal of Toxicology Cutaneous and Ocular Toxicology · doi:10.3109/15569528209051516 · Cited by 73
A colorimetric assay for chemical heparin in plasma
Klein, M. D., Drongowski, R. A., Linhardt, R. J., & Langer, R. (1982) · Analytical Biochemistry · doi:10.1016/0003-2697(82)90219-6 · Cited by 58
Migdał, M., Chudzynska-Pomianowska, E., Vause, E., Henry, E., & Lazar, J. D. (2005) · PEDIATRICS · doi:10.1542/peds.2004-0656 · Cited by 54
Sølvik, U. Ø., Røraas, T., Christensen, N. G., & Sandberg, S. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.210781 · Cited by 49
Heinemann, L., & Boecker, D. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500420 · Cited by 28
Blood extraction from lancet wounds using vacuum combined with skin stretching
Cunningham, D. D., Henning, T. P., Shain, E. B., Young, D. F., Hannig, J., Barua, E., & Lee, R. C. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00798.2001 · Cited by 27
Landis, E. M. (1938) · Journal of Investigative Dermatology · doi:10.1038/jid.1938.28 · Cited by 22
Cunningham, D. D., Henning, T. P., Shain, E. B., Young, D. F., Elstrom, T. A., Taylor, E. J., Schroder, S. M., Gatcomb, P., & Tamborlane, W. V. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050501952 · Cited by 21
Normal variation in cutaneous blood content and red blood cell velocity in humans
Simonen, P., O'Brien, M., Hamilton, C., Ashcroft, J., & Denham, J. W. (1997) · Physiological Measurement · doi:10.1088/0967-3334/18/3/001 · Cited by 17
Comparing analytic performance criteria: Evaluation of HbA1c certification criteria as an example
Rohlfing, C. L., Parvin, C. A., Sacks, D. B., & Little, R. R. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.03.034 · Cited by 14
Optimizing Outpatient Phlebotomy Staffing: Tools to Assess Staffing Needs and Monitor Effectiveness
Mijailovic, A. S., Tanasijevic, M. J., Goonan, E. M., Le, R. D., Baum, J. M., & Melanson, S. E. F. (2014) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2013-0450-oa · Cited by 13
Analysis of MEMS-Based Microneedles for Blood Monitoring
Ganesan, A., Kumar, H., Swaminathan, S., Singh, K. K., Joy, R. A., Sood, N., Gokhale, T., & Mittal, R. K. (2014) · BioNanoScience · doi:10.1007/s12668-013-0122-5 · Cited by 9
Wei, C.-H., Peng, T.-C., Wang, P.-Y., Lin, J.-J., Chuang, M.-L., & Chen, C.-C. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.02.011 · Cited by 3
Cited by
Enabling Technologies for Personalized and Precision Medicine
Ho, D., Quake, S. R., McCabe, E. R. B., Chng, W. J., Chow, E. K., Ding, X., Gelb, B. D., Ginsburg, G. S., Hassenstab, J., Ho, C.-M., et al. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.12.021 · Cited by 517
“Wearables and other classes of emerging technologies may overcome the challenges of infrequent measurements to improve the accuracy of treatment response assessment, thereby improving the design of personalized interventions [98].”
BackgroundMeng, Z., Zhou, X., Xu, J., Han, X., Dong, Z., Wang, H., Zhang, Y., She, J., Xu, L., Wang, C., et al. (2019) · Advanced Materials · doi:10.1002/adma.201900927 · Cited by 362
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Qu, F., Geng, R., Liu, Y., & Zhu, J. (2022) · Theranostics · doi:10.7150/thno.69999 · Cited by 321
Stimuli-responsive transdermal microneedle patches
Makvandi, P., Jamaledin, R., Chen, G., Baghbantaraghdari, Z., Zare, E. N., Di Natale, C., Onesto, V., Vecchione, R., Lee, J., Tay, F. R., et al. (2021) · Materials Today · doi:10.1016/j.mattod.2021.03.012 · Cited by 283
Metadata
- Authors
- Blicharz, T. M., Gong, P., Bunner, B. M., Chu, L. L., Leonard, K. M., Wakefield, J. A., Williams, R. E., Dadgar, M., Tagliabue, C. A., El Khaja, R., Marlin, S. L., Haghgooie, R., Davis, S. P., Chickering, D. E., & Bernstein, H.
- Venue
- Nature Biomedical Engineering
- Published
- 2018-02-19
- Volume
- 2
- Issue
- 3
- Pages
- 151-157
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2792519182
- Cited by
- 216
- References
- 35
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.