Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Personalized virtual-heart technology for guiding the ablation of infarct-related ventricular tachycardia

Open access
Prakosa, Adityo, Arevalo, Hermenegild J., Deng, Dongdong, Boyle, Patrick M., Nikolov, Plamen P., Ashikaga, Hiroshi, Blauer, Joshua J. E., Ghafoori, Elyar, Park, Carolyn J., Blake, Robert C., Han, Frederick T., MacLeod, Rob S., Halperin, Henry R., Callans, David J., Ranjan, Ravi, Chrispin, Jonathan, Nazarian, Saman, Trayanova, Natalia A. · 2018 · Nature Biomedical Engineering

Abstract

Ventricular tachycardia (VT), which can lead to sudden cardiac death, occurs frequently in patients with myocardial infarction. Catheter-based radio-frequency ablation of cardiac tissue has achieved only modest efficacy, owing to the inaccurate identification of ablation targets by current electrical mapping techniques, which can lead to extensive lesions and to a prolonged, poorly tolerated procedure. Here, we show that personalized virtual-heart technology based on cardiac imaging and computational modelling can identify optimal infarct-related VT ablation targets in retrospective animal (five swine) and human studies (21 patients), as well as in a prospective feasibility study (five patients). We first assessed, using retrospective studies (one of which included a proportion of clinical images with artefacts), the capability of the technology to determine the minimum-size ablation targets for eradicating all VTs. In the prospective study, VT sites predicted by the technology were targeted directly, without relying on prior electrical mapping. The approach could improve infarct-related VT ablation guidance, where accurate identification of patient-specific optimal targets could be achieved on a personalized virtual heart before the clinical procedure. A personalized virtual-heart model that determines optimal radio-frequency ablation targets for infarct-related tachycardia is validated in retrospective large-animal and patient studies, and in a prospective study in patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-018-0282-2

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

See all 297

Metadata

Authors
Prakosa, A., Arevalo, H. J., Deng, D., Boyle, P. M., Nikolov, P. P., Ashikaga, H., Blauer, J. J. E., Ghafoori, E., Park, C. J., Blake, R. C., Han, F. T., MacLeod, R. S., Halperin, H. R., Callans, D. J., Ranjan, R., Chrispin, J., Nazarian, S., & Trayanova, N. A.
Venue
Nature Biomedical Engineering
Published
2018-09-03
Volume
2
Issue
10
Pages
732-740
ISSN
2157-846X (ISSN-L)
OpenAlex
W2888118590
Cited by
297
References
35
FWCI
19.10
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Personalized virtual-heart technology for guiding the ablation of infarct-related ventricular tachycardia. https://app.cochat.ai/papers/10.1038/s41551-018-0282-2
The paper
Prakosa, A., Arevalo, H. J., Deng, D., Boyle, P. M., Nikolov, P. P., Ashikaga, H., Blauer, J. J. E., Ghafoori, E., Park, C. J., Blake, R. C., Han, F. T., MacLeod, R. S., Halperin, H. R., Callans, D. J., Ranjan, R., Chrispin, J., Nazarian, S., & Trayanova, N. A. (2018). Personalized virtual-heart technology for guiding the ablation of infarct-related ventricular tachycardia. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-018-0282-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.