Ultrabright fluorescent nanoscale labels for the femtomolar detection of analytes with standard bioassays
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
The detection and quantification of low-abundance molecular biomarkers in biological samples is challenging. Here, we show that a plasmonic nanoscale construct serving as an ‘add-on’ label for a broad range of bioassays improves their signal-to-noise ratio and dynamic range without altering their workflow and readout devices. The plasmonic construct consists of a bovine serum albumin scaffold with approximately 210 IRDye 800CW fluorophores (with a fluorescence intensity approximately 6,700-fold that of a single 800CW fluorophore), a polymer-coated gold nanorod acting as a plasmonic antenna and biotin as a high-affinity biorecognition element. Its emission wavelength can be tuned over the visible and near-infrared spectral regions by modifying its size, shape and composition. It improves the limit of detection in fluorescence-linked immunosorbent assays by up to 4,750-fold and is compatible with multiplexed bead-based immunoassays, immunomicroarrays, flow cytometry and immunocytochemistry methods, and it shortens overall assay times (to 20 min) and lowers sample volumes, as shown for the detection of a pro-inflammatory cytokine in mouse interstitial fluid and of urinary biomarkers in patient samples. A plasmonic nanoscale construct serving as a customizable ‘add-on’ fluorescent label improves the signal-to-noise ratio and dynamic range of a range of fluorescence-based bioassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jain, P. K., Lee, K. S., El-Sayed, I. H., & El-Sayed, M. A. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057170o · Cited by 4,603
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
The exciton model in molecular spectroscopy
Kasha, M., Rawls, H. R., & Ashraf El-Bayoumi, M. (1965) · Pure and Applied Chemistry · doi:10.1351/pac196511030371 · Cited by 4,253
The golden age: gold nanoparticles for biomedicine
Dreaden, E. C., Alkilany, A. M., Huang, X., Murphy, C. J., & El-Sayed, M. A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15237h · Cited by 3,550
Enhancement and Quenching of Single-Molecule Fluorescence
Anger, P., Bharadwaj, P., & Novotny, L. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.113002 · Cited by 3,158
Mishra, J., Dent, C., Tarabishi, R., Mitsnefes, M. M., Ma, Q., Kelly, C., Ruff, S. M., Zahedi, K., Shao, M., Bean, J., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)74811-x · Cited by 2,394
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Large single-molecule fluorescence enhancements produced by a bowtie nanoantenna
Kinkhabwala, A., Yu, Z., Fan, S., Avlasevich, Y., Müllen, K., & Moerner, W. E. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.187 · Cited by 2,047
Gold Nanorods: From Synthesis and Properties to Biological and Biomedical Applications
Huang, X., Neretina, S., & El‐Sayed, M. A. (2009) · Advanced Materials · doi:10.1002/adma.200802789 · Cited by 1,921
Gold nanorods and their plasmonic properties
Chen, H., Shao, L., Li, Q., & Wang, J. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35367a · Cited by 1,838
Cited by
Gold Nanorods: The Most Versatile Plasmonic Nanoparticles
Zheng, J., Cheng, X., Zhang, H., Bai, X., Ai, R., Shao, L., & Wang, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00422 · Cited by 651
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Self-citationRecent Advances in Microfluidic Technology for Bioanalysis and Diagnostics
Berlanda, S. F., Breitfeld, M., Dietsche, C. L., & Dittrich, P. S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04366 · Cited by 305
Emerging ELISA derived technologies for in vitro diagnostics
Peng, P., Liu, C., Li, Z., Xue, Z., Mao, P., Hu, J., Xu, F., Yao, C., & You, M. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116605 · Cited by 272
Gupta, R., Gupta, P., Wang, S., Melnykov, A., Jiang, Q., Seth, A., Wang, Z., Morrissey, J. J., George, I., Gandra, S., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-01001-1 · Cited by 213
“To achieve this, we used an ultrabright fluorescent nanoscale construct that we have recently introduced 27 , called plasmonic fluor, as a bimodal colorimetric and fluorescent reporter in LFAs (Fig.”
InfluentialSelf-citationSemeniak, D., Cruz, D. F., Chilkoti, A., & Mikkelsen, M. H. (2023) · Advanced Materials · doi:10.1002/adma.202107986 · Cited by 184
Plasmonic nanoparticle sensors: current progress, challenges, and future prospects
Kant, K., Beeram, R., Cao, Y., dos Santos, P. S. S., González-Cabaleiro, L., García-Lojo, D., Guo, H., Joung, Y., Kothadiya, S., Lafuente, M., et al. (2024) · Nanoscale Horizons · doi:10.1039/d4nh00226a · Cited by 182
Self-citationRecent Developments in Plasmonic Nanostructures for Metal Enhanced Fluorescence-Based Biosensing
Badshah, M. A., Koh, N. Y., Zia, A. W., Abbas, N., Zahra, Z., & Saleem, M. W. (2020) · Nanomaterials · doi:10.3390/nano10091749 · Cited by 171
Qin, J., Wang, W., Gao, L., & Yao, S. Q. (2022) · Chemical Science · doi:10.1039/d1sc06269g · Cited by 119
Metadata
- Authors
- Luan, J., Seth, A., Gupta, R., Wang, Z., Rathi, P., Cao, S., Gholami Derami, H., Tang, R., Xu, B., Achilefu, S., Morrissey, J. J., & Singamaneni, S.
- Venue
- Nature Biomedical Engineering
- Published
- 2020-04-20
- Volume
- 4
- Issue
- 5
- Pages
- 518-530
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3016940372
- Cited by
- 201
- References
- 62
- FWCI
- 17.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.