Ultrabright fluorescent nanoscale labels for the femtomolar detection of analytes with standard bioassays
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
The detection and quantification of low-abundance molecular biomarkers in biological samples is challenging. Here, we show that a plasmonic nanoscale construct serving as an ‘add-on’ label for a broad range of bioassays improves their signal-to-noise ratio and dynamic range without altering their workflow and readout devices. The plasmonic construct consists of a bovine serum albumin scaffold with approximately 210 IRDye 800CW fluorophores (with a fluorescence intensity approximately 6,700-fold that of a single 800CW fluorophore), a polymer-coated gold nanorod acting as a plasmonic antenna and biotin as a high-affinity biorecognition element. Its emission wavelength can be tuned over the visible and near-infrared spectral regions by modifying its size, shape and composition. It improves the limit of detection in fluorescence-linked immunosorbent assays by up to 4,750-fold and is compatible with multiplexed bead-based immunoassays, immunomicroarrays, flow cytometry and immunocytochemistry methods, and it shortens overall assay times (to 20 min) and lowers sample volumes, as shown for the detection of a pro-inflammatory cytokine in mouse interstitial fluid and of urinary biomarkers in patient samples. A plasmonic nanoscale construct serving as a customizable ‘add-on’ fluorescent label improves the signal-to-noise ratio and dynamic range of a range of fluorescence-based bioassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jain, P. K., Lee, K. S., El-Sayed, I. H., & El-Sayed, M. A. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057170o · Cited by 4,603
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
The exciton model in molecular spectroscopy
Kasha, M., Rawls, H. R., & Ashraf El-Bayoumi, M. (1965) · Pure and Applied Chemistry · doi:10.1351/pac196511030371 · Cited by 4,253
The golden age: gold nanoparticles for biomedicine
Dreaden, E. C., Alkilany, A. M., Huang, X., Murphy, C. J., & El-Sayed, M. A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15237h · Cited by 3,550
Enhancement and Quenching of Single-Molecule Fluorescence
Anger, P., Bharadwaj, P., & Novotny, L. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.113002 · Cited by 3,158
Mishra, J., Dent, C., Tarabishi, R., Mitsnefes, M. M., Ma, Q., Kelly, C., Ruff, S. M., Zahedi, K., Shao, M., Bean, J., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)74811-x · Cited by 2,394
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Large single-molecule fluorescence enhancements produced by a bowtie nanoantenna
Kinkhabwala, A., Yu, Z., Fan, S., Avlasevich, Y., Müllen, K., & Moerner, W. E. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.187 · Cited by 2,047
Gold Nanorods: From Synthesis and Properties to Biological and Biomedical Applications
Huang, X., Neretina, S., & El‐Sayed, M. A. (2009) · Advanced Materials · doi:10.1002/adma.200802789 · Cited by 1,921
Gold nanorods and their plasmonic properties
Chen, H., Shao, L., Li, Q., & Wang, J. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35367a · Cited by 1,838
Plasmonic Enhancement of Molecular Fluorescence
Tam, F., Goodrich, G. P., Johnson, B. R., & Halas, N. J. (2007) · Nano Letters · doi:10.1021/nl062901x · Cited by 956
Mining the plasma proteome for cancer biomarkers
Hanash, S. M., Pitteri, S. J., & Faca, V. M. (2008) · Nature · doi:10.1038/nature06916 · Cited by 891
Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye
de la Rica, R., & Stevens, M. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.186 · Cited by 873
Haes, A. J., Chang, L., Klein, W. L., & Van Duyne, R. P. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044087q · Cited by 864
Fluorescent Polymer Nanoparticles Based on Dyes: Seeking Brighter Tools for Bioimaging
Reisch, A., & Klymchenko, A. S. (2016) · Small · doi:10.1002/smll.201503396 · Cited by 634 · cited 1×
“21,25 One solution to prevent the formation of non-emissive H-aggregates is to engineer the inter-fluorophore distance and orientation, for example, by modifying the fluorophore with bulky side groups 26,27 or using charged dyes with hydrophobic counterions 18 .”
Lee, K.-S., & El-Sayed, M. A. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp054385p · Cited by 618
Fluorescence Enhancement by Au Nanostructures: Nanoshells and Nanorods
Bardhan, R., Grady, N. K., Cole, J. R., Joshi, A., & Halas, N. J. (2009) · ACS Nano · doi:10.1021/nn900001q · Cited by 617
Urinary biomarkers in the early diagnosis of acute kidney injury
Han, W. K., Waikar, S. S., Johnson, A., Betensky, R. A., Dent, C. L., Devarajan, P., & Bonventre, J. V. (2008) · Kidney International · doi:10.1038/sj.ki.5002715 · Cited by 585
Ma, Y., Li, W., Cho, E. C., Li, Z., Yu, T., Zeng, J., Xie, Z., & Xia, Y. (2010) · ACS Nano · doi:10.1021/nn102237c · Cited by 584
Ultrasensitive detection of circulating exosomes with a 3D-nanopatterned microfluidic chip
Zhang, P., Zhou, X., He, M., Shang, Y., Tetlow, A. L., Godwin, A. K., & Zeng, Y. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0356-9 · Cited by 554
The biotin‐streptavidin interaction can be reversibly broken using water at elevated temperatures
Holmberg, A., Blomstergren, A., Nord, O., Lukacs, M., Lundeberg, J., & Uhlén, M. (2005) · ELECTROPHORESIS · doi:10.1002/elps.200410070 · Cited by 477
Abadeer, N. S., Brennan, M. R., Wilson, W. L., & Murphy, C. J. (2014) · ACS Nano · doi:10.1021/nn502887j · Cited by 407 · cited 1×
“The results from independent experiment are shown in the main manuscript (Figure 6) as well as in Figure S46, 47.”
Engineered SERS Substrates with Multiscale Signal Enhancement: Nanoparticle Cluster Arrays
Yan, B., Thubagere, A., Premasiri, W. R., Ziegler, L. D., Dal Negro, L., & Reinhard, B. M. (2009) · ACS Nano · doi:10.1021/nn800836f · Cited by 384
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363 · cited 1×
“53 Here, we employed p-FLISA to measure the concentrations of a proinflammation cytokine (IL-6) in skin interstitial fluid obtained from mice immune-stimulated with lipopolysaccharide (LPS) and naïve mice (as controls).”
Biomarkers of neurodegeneration for diagnosis and monitoring therapeutics
Shaw, L. M., Korecka, M., Clark, C. M., Lee, V. M.-Y., & Trojanowski, J. Q. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2176 · Cited by 339
Protein microarrays with carbon nanotubes as multicolor Raman labels
Chen, Z., Tabakman, S. M., Goodwin, A. P., Kattah, M. G., Daranciang, D., Wang, X., Zhang, G., Li, X., Liu, Z., Utz, P. J., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1501 · Cited by 322
Resonant Plasmonic Enhancement of Single-Molecule Fluorescence by Individual Gold Nanorods
Khatua, S., Paulo, P. M. R., Yuan, H., Gupta, A., Zijlstra, P., & Orrit, M. (2014) · ACS Nano · doi:10.1021/nn406434y · Cited by 300
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Tabakman, S. M., Lau, L., Robinson, J. T., Price, J., Sherlock, S. P., Wang, H., Zhang, B., Chen, Z., Tangsombatvisit, S., Jarrell, J. A., et al. (2011) · Nature Communications · doi:10.1038/ncomms1477 · Cited by 256
Collective fluorescence switching of counterion-assembled dyes in polymer nanoparticles
Reisch, A., Didier, P., Richert, L., Oncul, S., Arntz, Y., Mély, Y., & Klymchenko, A. S. (2014) · Nature Communications · doi:10.1038/ncomms5089 · Cited by 226 · cited 2×
“…we introduce a stable and bright fluorescent nanoconstruct, termed ‘plasmonic-fluor’, which exhibits up to 6700 (± 900)-fold brighter signal compared to the corresponding single near infrared (NIR) fluorophore (800CW, LI-COR), outperforming existing nanoengineered fluorescent structures 18–24 .”
High-sensitivity assays for troponin in patients with cardiac disease
Westermann, D., Neumann, J. T., Sörensen, N. A., & Blankenberg, S. (2017) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.48 · Cited by 222
Xu, Z., Peng, S., Wang, Y., Zhang, J., Lazar, A. I., & Guo, D. (2016) · Advanced Materials · doi:10.1002/adma.201601719 · Cited by 217
Hu, J., Zhang, Z.-L., Wen, C.-Y., Tang, M., Wu, L.-L., Liu, C., Zhu, L., & Pang, D.-W. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01427 · Cited by 204
Thousand‐fold Enhancement of Single‐Molecule Fluorescence Near a Single Gold Nanorod
Yuan, H., Khatua, S., Zijlstra, P., Yorulmaz, M., & Orrit, M. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201208125 · Cited by 200 · cited 1×
“44,57 To this end, we have employed AuNR@Ag (silver (Ag) coated AuNR) nanocuboids with LSPR wavelength of 520 nm to fabricate plasmonic-fluor-Cy3 (Figure 3i, S18).”
Ge, S., Kojio, K., Takahara, A., & Kajiyama, T. (1998) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856298x00479 · Cited by 193
Protein microarray detection strategies: focus on direct detection technologies
Espina, V., Woodhouse, E. C., Wulfkuhle, J., Asmussen, H. D., Petricoin, E. F., & Liotta, L. A. (2004) · Journal of Immunological Methods · doi:10.1016/j.jim.2004.04.013 · Cited by 186
Munier, M., Jubeau, S., Wijaya, A., Morançais, M., Dumay, J., Marchal, L., Jaouen, P., & Fleurence, J. (2014) · Food Chemistry · doi:10.1016/j.foodchem.2013.10.113 · Cited by 185
A Sensitive Aβ Oligomer Assay Discriminates Alzheimer's and Aged Control Cerebrospinal Fluid
Savage, M. J., Kalinina, J., Wolfe, A., Tugusheva, K., Korn, R., Cash-Mason, T., Maxwell, J. W., Hatcher, N. G., Haugabook, S. J., Wu, G., et al. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.1675-13.2014 · Cited by 183
Colloidally Stable and Surfactant-Free Protein-Coated Gold Nanorods in Biological Media
Tebbe, M., Kuttner, C., Männel, M., Fery, A., & Chanana, M. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b00335 · Cited by 179
A plasmonic chip for biomarker discovery and diagnosis of type 1 diabetes
Zhang, B., Kumar, R. B., Dai, H., & Feldman, B. J. (2014) · Nature Medicine · doi:10.1038/nm.3619 · Cited by 176
Melnychuk, N., & Klymchenko, A. S. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b05840 · Cited by 176 · cited 2×
“23 Here, we introduce a stable and bright fluorescent nanoconstruct, termed ‘plasmonic-fluor’, which exhibits up to 6700 (± 900)-fold brighter signal compared to the corresponding single near infrared (NIR) fluorophore (800CW, LI-COR), outperforming existing nanoengineered fluorescent structures…”
Giant light-harvesting nanoantenna for single-molecule detection in ambient light
Trofymchuk, K., Reisch, A., Didier, P., Fras, F., Gilliot, P., Mely, Y., & Klymchenko, A. S. (2017) · Nature Photonics · doi:10.1038/s41566-017-0001-7 · Cited by 175 · cited 1×
“23,28 Again, this method is only applicable to charged fluorophores and broad application of these nanostructures in fluorescence-based bioanalytical and bioimaging techniques has not been demonstrated.”
Azide-Derivatized Gold Nanorods: Functional Materials for “Click” Chemistry
Gole, A., & Murphy, C. J. (2008) · Langmuir · doi:10.1021/la7026303 · Cited by 173
Photoluminescence of Gold Nanorods: Purcell Effect Enhanced Emission from Hot Carriers
Cai, Y., Liu, J. G., Tauzin, L. J., Huang, D., Sung, E. R., Zhang, H., Joplin, A., Chang, W., Nordlander, P. J., & Link, S. (2017) · ACS Nano · doi:10.1021/acsnano.7b07402 · Cited by 165
Huang, L., Liao, T., Wang, J., Ao, L., Su, W., & Hu, J. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201705380 · Cited by 159
Diagnosis of Zika virus infection on a nanotechnology platform
Zhang, B., Pinsky, B. A., Ananta, J. S., Zhao, S., Arulkumar, S., Wan, H., Sahoo, M. K., Abeynayake, J. I., Waggoner, J. J., Hopes, C., et al. (2017) · Nature Medicine · doi:10.1038/nm.4302 · Cited by 156
Metal-enhanced fluorescence in the life sciences: here, now and beyond
Deng, W., Xie, F., Baltar, H. T. M. C. M., & Goldys, E. M. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp50206f · Cited by 152
In-Plane Plasmonic Antenna Arrays with Surface Nanogaps for Giant Fluorescence Enhancement
Flauraud, V., Regmi, R., Winkler, P. M., Alexander, D. T. L., Rigneault, H., van Hulst, N. F., Parajo, M. F. G., Wenger, J., & Brügger, J. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b04978 · Cited by 151
High Performance, Multiplexed Lung Cancer Biomarker Detection on a Plasmonic Gold Chip
Liu, B., Li, Y., Wan, H., Wang, L., Xu, W. L., Zhu, S., Liang, Y., Zhang, B., Lou, J., Dai, H., et al. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201603547 · Cited by 109
Size-Dependent Surface Enhanced Raman Scattering Activity of Plasmonic Nanorattles
Liu, K., Tadepalli, S., Tian, L., & Singamaneni, S. (2015) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b01401 · Cited by 99
Self-citationShulov, I., Oncul, S., Reisch, A., Arntz, Y., Collot, M., Mely, Y., & Klymchenko, A. S. (2015) · Nanoscale · doi:10.1039/c5nr04955e · Cited by 97
Blennow, K., & Zetterberg, H. (2015) · Nature Medicine · doi:10.1038/nm.3810 · Cited by 85
Add-on plasmonic patch as a universal fluorescence enhancer
Luan, J., Morrissey, J. J., Wang, Z., Derami, H. G., Liu, K., Cao, S., Jiang, Q., Wang, C., Kharasch, E. D., Naik, R. R., et al. (2018) · Light Science & Applications · doi:10.1038/s41377-018-0027-8 · Cited by 84
Self-citationTrofymchuk, K., Reisch, A., Shulov, I., Mély, Y., & Klymchenko, A. S. (2014) · Nanoscale · doi:10.1039/c4nr03718a · Cited by 78
Fluorescent nanoparticles as selective Cu(ii) sensors
Méallet‐Renault, R., Hérault, A., Vachon, J.-J., Pansu, R. B., Amigoni, S., & Larpent, C. (2005) · Photochemical & Photobiological Sciences · doi:10.1039/b513215k · Cited by 66
Critical Appraisal of Four IL-6 Immunoassays
Thompson, D. K., Huffman, K. M., Kraus, W. E., & Kraus, V. B. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030659 · Cited by 61
Gold nanocages with built-in artificial antibodies for label-free plasmonic biosensing
Tian, L., Liu, K., Morrissey, J. J., Gandra, N., Kharasch, E. D., & Singamaneni, S. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb21551b · Cited by 45
Self-citationPlasmonic micro-beads for fluorescence enhanced, multiplexed protein detection with flow cytometry
Zhang, B., Jiang, Y., Zou, Y., Gong, M., Chen, H., Hong, G., Antaris, A. L., Li, X., Liu, C., Chen, C., et al. (2014) · Chemical Science · doi:10.1039/c4sc01206b · Cited by 43
Nedrebø, T., Reed, R. K., Jonsson, R., Berg, A., & Wiig, H. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.057216 · Cited by 42
Roth, S., Hadass, O., Cohen, M., et al. (2018) · Small · doi:10.1002/smll.201803751 · Cited by 37
Protein Microarrays with Novel Microfluidic Methods: Current Advances
Dixit, C. K., & Aguirre, G. R. (2014) · Microarrays · doi:10.3390/microarrays3030180 · Cited by 14
Roth, S., Hadass, O., Cohen, M., et al. (2019) · Small · doi:10.1002/smll.201970016 · Cited by 5
Cited by
Gold Nanorods: The Most Versatile Plasmonic Nanoparticles
Zheng, J., Cheng, X., Zhang, H., Bai, X., Ai, R., Shao, L., & Wang, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00422 · Cited by 651
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Self-citationRecent Advances in Microfluidic Technology for Bioanalysis and Diagnostics
Berlanda, S. F., Breitfeld, M., Dietsche, C. L., & Dittrich, P. S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04366 · Cited by 305
Emerging ELISA derived technologies for in vitro diagnostics
Peng, P., Liu, C., Li, Z., Xue, Z., Mao, P., Hu, J., Xu, F., Yao, C., & You, M. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116605 · Cited by 272
Gupta, R., Gupta, P., Wang, S., Melnykov, A., Jiang, Q., Seth, A., Wang, Z., Morrissey, J. J., George, I., Gandra, S., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-01001-1 · Cited by 213
“To achieve this, we used an ultrabright fluorescent nanoscale construct that we have recently introduced 27 , called plasmonic fluor, as a bimodal colorimetric and fluorescent reporter in LFAs (Fig.”
InfluentialSelf-citation
Metadata
- Authors
- Luan, J., Seth, A., Gupta, R., Wang, Z., Rathi, P., Cao, S., Gholami Derami, H., Tang, R., Xu, B., Achilefu, S., Morrissey, J. J., & Singamaneni, S.
- Venue
- Nature Biomedical Engineering
- Published
- 2020-04-20
- Volume
- 4
- Issue
- 5
- Pages
- 518-530
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3016940372
- Cited by
- 201
- References
- 62
- FWCI
- 17.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.