Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 283

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

In vivo non-invasive confocal fluorescence imaging beyond 1,700 nm using superconducting nanowire single-photon detectors

Open access
Wang, Feifei, Ren, Fuqiang, Ma, Zhuoran, Qu, Liangqiong, Gourgues, Ronan, Xu, Chun, Baghdasaryan, Ani, Li, Jiachen, Zadeh, Iman Esmaeil, Los, Johannes W. N., Fognini, Andreas, Qin-Dregely, Jessie, Dai, Hongjie·2022·Nature Nanotechnology

Abstract

Light scattering by biological tissues sets a limit to the penetration depth of high-resolution optical microscopy imaging of live mammals in vivo. An effective approach to reduce light scattering and increase imaging depth is to extend the excitation and emission wavelengths to the second near-infrared window (NIR-II) at >1,000 nm, also called the short-wavelength infrared window. Here we show biocompatible core–shell lead sulfide/cadmium sulfide quantum dots emitting at ~1,880 nm and superconducting nanowire single-photon detectors for single-photon detection up to 2,000 nm, enabling a one-photon excitation fluorescence imaging window in the 1,700–2,000 nm (NIR-IIc) range with 1,650 nm excitation—the longest one-photon excitation and emission for in vivo mouse imaging so far. Confocal fluorescence imaging in NIR-IIc reached an imaging depth of ~1,100 μm through an intact mouse head, and enabled non-invasive cellular-resolution imaging in the inguinal lymph nodes of mice without any surgery. We achieve in vivo molecular imaging of high endothelial venules with diameters as small as ~6.6 μm, as well as CD169 + macrophages and CD3 + T cells in the lymph nodes, opening the possibility of non-invasive intravital imaging of immune trafficking in lymph nodes at the single-cell/vessel-level longitudinally. Biocompatible core–shell quantum dots and superconducting nanowire single-photon detector enable non-invasive one-photon excitation fluorescence imaging at 1,880 nm for in vivo imaging at 1,100 μm depth.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41565-022-01130-3

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 283

Metadata

Authors
Wang, F., Ren, F., Ma, Z., Qu, L., Gourgues, R., Xu, C., Baghdasaryan, A., Li, J., Zadeh, I. E., Los, J. W. N., Fognini, A., Qin-Dregely, J., & Dai, H.
Venue
Nature Nanotechnology
Published
2022-05-23
Volume
17
Issue
6
Pages
653-660
ISSN
  • 1748-3387 (ISSN-L)
  • 1748-3395
OpenAlex
W4281389665
Cited by
283
References
39
FWCI
30.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo non-invasive confocal fluorescence imaging beyond 1,700 nm using superconducting nanowire single-photon detectors. https://app.cochat.ai/papers/10.1038/s41565-022-01130-3
The paper
Wang, F., Ren, F., Ma, Z., Qu, L., Gourgues, R., Xu, C., Baghdasaryan, A., Li, J., Zadeh, I. E., Los, J. W. N., Fognini, A., Qin-Dregely, J., & Dai, H. (2022). In vivo non-invasive confocal fluorescence imaging beyond 1,700 nm using superconducting nanowire single-photon detectors. Nature Nanotechnology. https://doi.org/10.1038/s41565-022-01130-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.