Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Improvements in atom-light coherence are foundational to progress in quantum information science 1 , quantum optics 2 , and precision metrology 3 . Optical atomic clocks require local oscillators with exceptional optical coherence due to the challenge of performing spectroscopy on their ultra-narrow linewidth clock transitions. Advances in laser stabilization have thus enabled rapid progress in clock precision 4,5 . A new class of ultrastable lasers based on cryogenic silicon reference cavities 6 has recently demonstrated the longest optical coherence times to date 7 . In this work we utilize such a local oscillator, along with a state-of-the-art frequency comb for coherence transfer, with two Sr optical lattice clocks to achieve an unprecedented level of clock stability. Through an anti-synchronous comparison, the fractional instability of
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Currently, precise OACs have achieved a stability of 4.8 × 10 -17 at 1 s and 6.6 × 10 -19 in 1 h for a two clock comparison [19]”
From Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links (2023) · cites this paper as [19]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, with the fast development of high-precision clock manufacturing technology in recent years, optical atomic clocks (OACs), which have uncertainty and accuracy level of around 1 × 10 -18 and even higher have been developed in various laboratories [17][18][19][20].”
From Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links (2023) · cites this paper as [19]
The cited source says what the claim attributes to it.
In the citing paper
“Since we can significantly improve the stability of the clock after a period (e.g., one hour) of integration, as demonstrated by [19], the height unification accuracy could be improved after a period of integration.”
From Unification of a Global Height System at the Centimeter-Level Using Precise Clock Frequency Signal Links (2023) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Self-citationChou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationAtomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citationCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Cited by
Items 501–549 of 549
Yingxin, 陈. C., Lu, X., & Chang, H. (2023) · Acta Optica Sinica · doi:10.3788/aos230444
Field-deployable Ultra-low-noise Clockwork for Precision Optical Clocks
Giunta, M., Fischer, M., Lilienfein, N., Wolferstetter, M., Holzberger, S., Saint-Jalm, S., Skopnik, F., Lessing, M., Hänsel, W., & Holzwarth, R. (2020) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2020.sm1n.3
Self-citationOptical Frequency Divider for Spectroscopy and Optical Frequency Measurement
Jiang, Y., Yao, Y., Li, B., Chen, X., Sun, Y., Hao, Y., & Ma, L.-S. (2020) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2020.sf3g.5
Low-noise optical frequency divider for precision measurement
Jiang, Y., Shi, H., Yao, Y., Yu, H., & Ma, L.-S. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012009
Broadband Commercial Frequency Combs for Stability Transfer in Quantum Applications
Smith, C., Cataño-Lopez, S. B., Sodergren, B., Barnes, E., Choura, S., Enlow, E., Spiess, A., Vogel, K. D., Knabe, K., Attar, A., et al. (2026) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2026.jtu.177
Lompe, T., Woschnik, P., Schlichting, K., Lago-Rivera, D., Wu, Y., Steinmetz, T., Fricke, A., Fischer, M., Giunta, M., & Holzwarth, R. (2024) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2024.sm2g.5
Self-citationWang, Y., Yang, F., Cao, K., Shi, J., & Han, L. (2024) · Advanced Fiber Laser Conference (AFL) · doi:10.1117/12.3022792
Towards a Sr Optical Lattice Clock at ROA : First implementations
Martínez, H. Á., Perales, A. E., Delgado, I. C., González, J. R., de Arellano, J. M. S. R., Suárez, V. B., Sánchez, J. M. G., Bohórquez, J. C., Vélez, C., Pinillos, H. E., et al. (2023) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs57587.2023.10272210
Frequency comb supporting sub-10-20 fractional stability
Volkov, M., Tian, H., Liao, T., Puppe, T., Predehl, K., Lu, B., Fang, Z., Lin, Y., & Steinmeyer, G. (2026) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2026.sth3h.1
Rao, B., Yang, X., Li, M., Chen, X., Ning, Y., Hu, Z., Dong, R., Zhang, S., & Zhang, P. (2025) · Chinese Optics Letters · doi:10.3788/col202624.011401
Coherent Optical Clock Down-Conversion Realizing Microwaves With 10-18 Absolute Stability
Nakamura, T., Davila-Rodriguez, J., Leopardi, H., Sherman, J. A., Fortier, T. M., Xie, X., Campbell, J. C., Diddams, S. A., McGrew, W. F., Zhang, X., et al. (2020) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2020.sm1n.2
Lin, Y., Zhang, Y., Wu, Q., Chen, J., Wang, D., & Xu, B. (2026) · Chinese Optics Letters · doi:10.3788/col202624.111404
郭, F. 峰. G., Lu, X., & Hong, C. (2026) · Acta Physica Sinica · doi:10.7498/aps.76.20261321
Ultrahigh‐Quality 780 nm Bragg Grating Fabry‐Pérot Cavity on an Etchless Lithium Niobate Platform
Fan, X., Bai, S., Li, H., Li, K., Zhai, K., Dong, W., Zhou, H., Zhang, X., Zhu, N., Wen, H., et al. (2026) · Laser & Photonics Review · doi:10.1002/lpor.71821
Near-term quantum computation with neutral atoms:From electronic states, to gates and algorithms
Mohan, M. (2025) · TU/e Research Portal
Sprenger, B., & Krok, P. (2021) · PhotonicsViews · doi:10.1002/phvs.202100023
Optical-to-microwave phase coherent link at 19th digit accuracy
Rauf, B., Baldoni, I., Wolferstetter, M., Fricke, A., Fischer, M., Giunta, M., & Holzwarth, R. (2024) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2024.sf3n.6
Self-citationMultipartite quantum clock synchronization via collective symmetric states
Keskin, U., Maranò, S., Conti, A., Shin, H., Lindsey, W. C., & Win, M. Z. (2026) · Quantum Science and Technology · doi:10.1088/2058-9565/aeac82
Operation and optical frequency comparisons with an ytterbium optical lattice clock
Condio, S. (2025) · PORTO@Iris · doi:10.13121/polito/porto/3002616
Phase-continuous comparison of three all-optical time scales over 20 daysPreprint
Lee, D., Kim, K., Hu, Z., Lewis, B., Warfield, W., Zhou, K., Collopy, A., Sherman, J. A., Kowligy, A. S., Patel, P., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-10562772/v1
Self-citationSingle-ion traps and cubic cavities for field-deployable laser-cooled optical atomic clocksPreprint
Spampinato, A., Stacey, J., Trigatzis, M. A., Mulholland, S., Vincent, N., Huang, G., Barwood, G. P., & Gill, P. (2026) · Research Square · doi:10.21203/rs.3.rs-9855657/v1
Improving Short-Term Stability in Optical Lattice Clocks by Quantum Nondemolition MeasurementsPreprint
Orenes, D. B., Sewell, R. J., Lodewyck, J., & Mitchell, M. W. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2109.08418
Optical Signals Synthesized from an Optical Lattice Clock with Uncertainty of 1.3E-17Preprint
Yao, Y., Jinpeng, Z., Shi, H., Yu, H., Ma, L., & Jiang, Y. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.11178
ФИЗИКА УЛЬТРАХОЛОДНЫХ АТОМОВ – 2024
наук, И. Ф. П. И. А. В. Р. С. О. Р. А., наук, И. Л. Ф. С. О. Р. А., наук, И. А. И. Э. С. О. Р. А., & университет, Н. Г. (2024) · Novosibirsk State University eBooks · doi:10.25205/978-5-85957-226-7
Spectrally enhanced gravitational redshift signals in photonic interferometryPreprint
Paczos, J., Grochowski, P. T., Bruno, N., Distante, E., Welte, S., & Zych, M. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.18131
Zheng, Q., Xu, K., Yang, J., Zhou, L., Ding, L., Jiang, X., & Bu, Z. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2606.17959
Dual-Comb Interferometry with Fiber-Based Comb Synthesizers
Picqué, N. (2022) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2022.jm4a.4
Speckle-based feedback control of optical dipole trap axial waist positionPreprint
Pershin, D. A., Kumpilov, D. A., Rudnev, A. E., Subbotin, G., Ibrahimov, A., Cojocaru, I. S., Khlebnikov, V. A., Pyrkh, I. A., Aksentsev, P. A., Kuzmin, S. A., et al. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2607.09414
Interferometry, Quantum Measurements and Cavity QED with Atoms
Bertoldi, A. D. (2019) · HAL
Zhadnov, N. O., Khronusova, O., Russkikh, A., Kolachevsky, N., & Masalov, A. V. (2026) · Research Square · doi:10.21203/rs.3.rs-11047099/v1
Anomaly detection in atomic clocks using machine learning and time series approach
Arunachalam, A. (2026) · Current Science · doi:10.18520/cs/v130/i4/314-324
наук, И. Л. Ф. С. О. Р. А., наук, И. Ф. П. И. А. В. Р. С. О. Р. А., наук, И. А. И. Э. С. О. Р. А., & университет, Н. Г. (2024) · Novosibirsk State University eBooks · doi:10.25205/978-5-85957-211-3
Hebib, Y. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2511.11879
All polarization-maintaining Er:fiber frequency comb based on nonlinear amplifying loop mirror
Li, M., Ning, K., Hou, L., Yan, L., Zhang, Y., Rao, B., Zhang, P., & Jiang, H. (2020) · Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR) · doi:10.1364/cleopr.2020.c4a_5
Herbers, S., Yu, J., Anders, L., Kawohl, J., Misera, M., Legero, T., Hanhijärvi, K., Wallin, A. E., Lindvall, T., Fordell, T., et al. (2023) · Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC) · doi:10.1109/cleo/europe-eqec57999.2023.10231948
Self-citationOptical control of coherent magneto-optical resonances in potassium
Tsvetkov, S., & Gateva, S. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2710/1/012026
Decoupling of External and Internal Dynamics in Driven Two-level SystemsPreprint
Böhringer, S., & Friedrich, A. (2024) · arXiv (Cornell University) · doi:10.48550/arxiv.2406.01511
Broadband birefringence spectroscopy with sub-kHz precisionPreprint
Prinz, M., Charczun, D., Bober, M., Narożnik, M., Morzyński, P., Galander, U., Heckl, O. H., & Masłowski, P. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2508.21545
Smart illumination for 3D-imaging of biological tissues
LeGoff, L., Mazzella, L., Cecchini, S., Levi-Valensi, N., Allain, M., Sentenac, A., & Galland, F. (2025) · Photoniques · doi:10.1051/photon/202513436
A Purely Mathematical Derivation of the Fine-Structure Constant Within 1.62σ of CODATA 2022Preprint
Macedonia, C. R. (2026) · Preprints.org · doi:10.20944/preprints202508.1294.v3
Observation of defect size evolution with annealing using optical scattering
Zhang, W., Gutierrez-Pena, B., Bagchi, F., Matteo, L., Samir, P., Zhao, E., Hossain, I., Avery, K., Potter, R., McColl, J., et al. (2026) · Applied Optics · doi:10.1364/ao.590924
Wang, K., Zhu, J., & Lu, Y. (2026) · International Conference on Optoelectronic Information and Optical Engineering (OIOE) · doi:10.1117/12.3116313
Balanced heterodyne detection of EOIM-based frequency- synthesized light at the shot noise limit
Yang, P., Tu, C., Shi, Z., & Liu, J. (2026) · Laser and Particle Beams · doi:10.3788/lpb.2026.10010
Zhang, J., Yang, B., Ni, T., Miao, Y., & Li, Y. (2026) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2026.107072
Accurate recovery of the two linewidths hidden in laser beatnote statisticsPreprint
Chen, J., Qi, Y., Pang, Y., Miao, J., Wang, C., Yao, Y., Chen, Z.-A., Lei, R.-Q., Ge, Z., Jiang, Y., et al. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2609.36592
Feedback-Controlled Self-Trapping of SolitonsPreprint
Islam, R., Shandilya, P. H., Song, Y., Niang, A., Carter, G., Carruthers, T., Menyuk, C. R., & Şimşek, E. (2026) · arXiv (Cornell University) · doi:10.13016/m2z5g7-1b4n
Metadata
- Authors
- Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., Matei, D. G., Legero, T., Giunta, M., Holzwarth, R., Riehle, F., Sterr, U., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- Physikalisch-Technische Bundesanstalt (DE)
- Menlo Systems (Germany) (DE)
- Corresponding author
- Oelker, E.
- Ye, J.
- ORCID
- Venue
- Nature Photonics
- Published
- 2019-07-29
- Volume
- 13
- Issue
- 10
- Pages
- 714-719
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W3103170714
- Cited by
- 475
- References
- 49
- Citations by year
- 2026: 37 · 2025: 70 · 2024: 75 · 2023: 74 · 2022: 61 · 2021: 68 · 2020: 71 · 2019: 18
- FWCI
- 23.96
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Photonics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (submittedVersion, cc-by-sa)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical atomic clocks, strontium optical lattice clock, clock stability, ultra-stable lasers, local oscillator, laser stabilization, quantum projection noise, quantum sensing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.