Cited by 341Blood Pressure and Hypertension StudiesNon-Invasive Vital Sign MonitoringCardiovascular Health and Disease Prevention

The DOI matches its Crossref record; 102 of the 109 references it cites were found in a registry or an index; 51 of the 152 sources its claims cite were checked for support.

Blood pressure and its variability: classic and novel measurement techniques

Open access
Schutte, Aletta E., Kollias, Anastasios, Stergiou, George S.·2022·Nature Reviews Cardiology

Abstract

Current hypertension guidelines recommend using the average values of several blood pressure (BP) readings obtained both in and out of the office for the diagnosis and management of hypertension. In-office BP measurement using an upper-arm cuff constitutes the evidence-based reference method for current BP classification and treatment targets. However, out-of-office BP evaluation using 24 h ambulatory or home BP monitoring is recommended by all major medical associations for obtaining further insights into the BP profile of an individual and how it relates to their daily activities. Importantly, the highly variable nature of office and out-of-office BP readings has been widely acknowledged, including the association of BP variability with cardiovascular outcomes. However, to date, the implications of BP variability on cardiovascular outcomes have largely been ignored, with limited application in clinical practice. Novel cuffless wearable technologies might provide a detailed assessment of the 24 h BP profile and behaviour over weeks or months. These devices offer many advantages for researchers and patients compared with traditional BP monitors, but their accuracy and utility remain uncertain. In this Review, we outline and compare conventional and novel methods and techniques for assessing average BP levels and BP variability, and reflect on the utility and potential of these methods for improving the treatment and management of patients with hypertension.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41569-022-00690-0

Cites

102 of 102 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

46 No full text of the sources · 27 Own interpretation · 20 Partly supported · 18 Supported · 7 Supported so far · 5 No basis given · 2 Sources not found · 1 Not supported · 1 Couldn’t confirm · accuracy not yet measured

Show all 71 claims

  • It may state two separate claims as one. 44
  • Probably not a substantial claim. 15
56 of 56
  • The paper relies on this without support.

    BP is a continuous dynamic variable.

    “The key challenge is that BP is a continuous dynamic variable that is inadequately represented by the snapshot measurements provided by all the current clinically available methods.”
  • The paper relies on this without support.

    Snapshot office BP measurements have been extremely effective in predicting cardiovascular risk.

    “However, given that snapshot office BP measurements have been extremely effective in predicting cardiovascular risk, the goal of improving cardiovascular risk prediction with existing out-of-office BP monitoring methods or BPV measurement methods remains a challenge.”
  • The paper relies on this without support.

    BP measurement is the only method for diagnosing and managing hypertension.

    “Regardless of the advances in novel technologies in this field, BP measurement remains the only method for the diagnosis and management of hypertension.”
3 of 3

Citations

Cites

Show all 109 references

Cited by

Sorted by citations

Items 201–300 of 341

Metadata

Authors
Schutte, A. E., Kollias, A., & Stergiou, G. S.
Affiliations
  • North-West University (ZA)
  • National and Kapodistrian University of Athens (GR)
Corresponding author
Schutte, Aletta E.
Venue
Nature Reviews Cardiology
Published
2022-04-19
Volume
19
Issue
10
Pages
643-654
ISSN
  • 1759-5002 (ISSN-L)
  • 1759-5010
OpenAlex
W4224274564
Cited by
335
References
109
Citations by year
2026: 77 · 2025: 101 · 2024: 79 · 2023: 70 · 2022: 8
FWCI
13.10
Type
journal article
Language
en
Open access
Locations
  • Nature Reviews Cardiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
blood pressure variability, hypertension, ambulatory blood pressure monitoring, home blood pressure monitoring, cardiovascular outcomes, blood pressure measurement methods, antihypertensive therapy
MeSH terms
Wearable Electronic Devices, Blood Pressure, Blood Pressure Determination, Humans, Hypertension, Blood Pressure Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-09-28, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-28 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review