Differential clock comparisons with a multiplexed optical lattice clock
The DOI matches its Crossref record; 70 of the 72 references it cites were found in a registry or an index.
Abstract
Rapid progress in optical atomic clock performance has advanced the frontiers of timekeeping, metrology and quantum science 1-3. Despite considerable efforts, the instabilities of most optical clocks remain limited by the local oscillator rather than the atoms themselves 4,5. Here we implement a 'multiplexed' one-dimensional optical lattice clock, in which spatially resolved strontium atom ensembles are trapped in the same optical lattice, interrogated simultaneously by a shared clock laser and read-out in parallel. In synchronous Ramsey interrogations of ensemble pairs we observe atom-atom coherence times of 26 s, a 270-fold improvement over the measured atom-laser coherence time, demonstrate a relative instability of [Formula: see text] (where τ is the averaging time) and reach a relative statistical uncertainty of 8.9 × 10-20 after 3.3 h of averaging. These results demonstrate that applications involving optical clock comparisons need not be limited by the instability of the local oscillator. We further realize a miniaturized clock network consisting of 6 atomic ensembles and 15 simultaneous pairwise comparisons with relative instabilities below [Formula: see text], and prepare spatially resolved, heterogeneous ensemble pairs of all four stable strontium isotopes. These results pave the way for multiplexed precision isotope shift measurements, spatially resolved characterization of limiting clock systematics, the development of clock-based gravitational wave and dark matter detectors 6-12 and new tests of relativity in the lab 13-16.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In 2022, the gravitational redshift effect is tested in 10 -21 , and the variation of sub-millimeter height differences can be detected [20,21].”
From Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks (2022) · cites this paper as [21]
In the citing paper
“At present, the gravitational redshift effect has been tested at the order of 10 -21 in the laboratory, and the optical fiber frequency transmission technique could basically meet the demand for clock comparison [20,21,33,53].”
From Performance Evaluation and Requirement Analysis for Chronometric Leveling with High-Accuracy Optical Clocks (2022) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Kitagawa, M., & Ueda, M. (1993) · Physical Review A · doi:10.1103/physreva.47.5138 · Cited by 1,741
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560 · cited 1×
“5(6) × 10 shift per 100 atom number difference.”
BackgroundAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Research works printed but not linked: 2
- Lattice-induced frequency shifts in Sr optical lattice clocks at the 10 −17 level. P G Westergaard, 10.1103/PhysRevLett.106.210801Phys. Rev. Lett. 1062108012011 · doi:10.1103/physrevlett.106.210801phys
- JILA SrI optical lattice clock with uncertainty of 2.0 × 10 −18. T Bothwell, 10.1088/1681-7575/ab4089Metrologia. 56650042019 · doi:10.1088/1681-7575/ab4089metrologia
Cited by
K S, U. (2025) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.18067974 · Cited by 733
Resolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Realizing spin squeezing with Rydberg interactions in an optical clock
Eckner, W. J., Oppong, N. D., Cao, A., Young, A. W., Milner, W. R., Robinson, J. M., Ye, J., & Kaufman, A. M. (2023) · Nature · doi:10.1038/s41586-023-06360-6 · Cited by 230
“The demonstrated protocol establishes an effective approach for reaching entanglement-enhanced optical atomic clocks, and is compatible with other existing experiments 5,23,40,45 .”
BackgroundMethodResultInfluentialQuantum networks with neutral atom processing nodes
Covey, J. P., Weinfurter, H., & Bernien, H. (2023) · npj Quantum Information · doi:10.1038/s41534-023-00759-9 · Cited by 180
Distributed quantum sensing with mode-entangled spin-squeezed atomic states
Malia, B. K., Wu, Y., Martínez-Rincón, J., & Kasevich, M. A. (2022) · Nature · doi:10.1038/s41586-022-05363-z · Cited by 188
Metadata
- Authors
- Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S.
- Affiliations
- University of Wisconsin–Madison (US)
- Corresponding author
- Kolkowitz, Shimon
- Venue
- Nature
- Published
- 2022-02-16
- Volume
- 602
- Issue
- 7897
- Pages
- 425-430
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W4212945630
- Semantic Scholar
- 75ac4bd913d140c84acb3aff28db524bdd1be5b9
- Cited by
- 150
- References
- 72
- Citations by year
- 2026: 15 · 2025: 47 · 2024: 34 · 2023: 36 · 2022: 18
- FWCI
- 13.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, clock comparison, clock instability, clock distribution, strontium isotopes, ultracold atoms
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.