Monolithic Chip for High-throughput Blood Cell Depletion to Sort Rare Circulating Tumor Cells
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Circulating tumor cells (CTCs) are a treasure trove of information regarding the location, type and stage of cancer and are being pursued as both a diagnostic target and a means of guiding personalized treatment. Most isolation technologies utilize properties of the CTCs themselves such as surface antigens (e.g., epithelial cell adhesion molecule or EpCAM) or size to separate them from blood cell populations. We present an automated monolithic chip with 128 multiplexed deterministic lateral displacement devices containing ~1.5 million microfabricated features (12 µm–50 µm) used to first deplete red blood cells and platelets. The outputs from these devices are serially integrated with an inertial focusing system to line up all nucleated cells for multi-stage magnetophoresis to remove magnetically-labeled white blood cells. The monolithic CTC-iChip enables debulking of blood samples at 15–20 million cells per second while yielding an output of highly purified CTCs. We quantified the size and EpCAM expression of over 2,500 CTCs from 38 patient samples obtained from breast, prostate, lung cancers, and melanoma. The results show significant heterogeneity between and within single patients. Unbiased, rapid, and automated isolation of CTCs using monolithic CTC-iChip will enable the detailed measurement of their physicochemical and biological properties and their role in metastasis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Self-citationAllard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Circulating Breast Tumor Cells Exhibit Dynamic Changes in Epithelial and Mesenchymal Composition
Yu, M., Bardia, A., Wittner, B. S., Stott, S. L., Smas, M. E., Ting, D. T., Isakoff, S. J., Ciciliano, J. C., Wells, M. N., Shah, A. M., et al. (2013) · Science · doi:10.1126/science.1228522 · Cited by 2,476
Self-citationde Bono, J. S., Scher, H. I., Montgomery, R. B., Parker, C., Miller, M. C., Tissing, H., Doyle, G. V., Terstappen, L. W. W. M., Pienta, K. J., & Raghavan, D. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-0872 · Cited by 2,182
Cohen, S. J., Punt, C. J. A., Iannotti, N., Saidman, B. H., Sabbath, K. D., Gabrail, N. Y., Picus, J., Morse, M., Mitchell, E., Miller, M. C., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.15.8923 · Cited by 1,841
Isolation of circulating tumor cells using a microvortex-generating herringbone-chip
Stott, S. L., Hsu, C.-H., Tsukrov, D. I., Yu, M., Miyamoto, D. T., Waltman, B. A., Rothenberg, S. M., Shah, A. M., Smas, M. E., Korir, G. K., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012539107 · Cited by 1,634
Self-citationContinuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Self-citationRiethdorf, S., Fritsche, H., Müller, V., Rau, T., Schindlbeck, C., Rack, B., Janni, W., Coith, C., Beck, K., Jänicke, F., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-1695 · Cited by 1,338
Cited by
Circulating tumor cells: biology and clinical significance
Lin, D., Shen, L., Luo, M., Zhang, K., Li, J., Yang, Q., Zhu, F., Zhou, D., Zheng, S., Chen, Y., et al. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00817-8 · Cited by 993
Technologies for circulating tumor cell separation from whole blood
Bankó, P., Lee, S. Y., Nagygyörgy, V., Zrínyi, M., Chae, C. H., Cho, D. H., & Telekes, A. (2019) · Journal of Hematology & Oncology · doi:10.1186/s13045-019-0735-4 · Cited by 358
Organ‐on‐chip models: Implications in drug discovery and clinical applications
Mittal, R., Woo, F. W., Castro, C. S., Cohen, M. A., Karanxha, J., Mittal, J., Chhibber, T., & Jhaveri, V. M. (2019) · Journal of Cellular Physiology · doi:10.1002/jcp.27729 · Cited by 234
“A study designed a so‐called CTC‐iChip, a microfluidic chip containing three separate technologies—magnetophoresis, inertial focusing, and deterministic lateral displacement to exclude components of whole blood that are not of concern (Fachin et al., 2017).”
MethodA Review on Deterministic Lateral Displacement for Particle Separation and Detection
Salafi, T., Zhang, Y., & Zhang, Y. (2019) · Nano-Micro Letters · doi:10.1007/s40820-019-0308-7 · Cited by 229
A role for microfluidic systems in precision medicine
Ayuso, J. M., Virumbrales-Muñoz, M., Lang, J. M., & Beebe, D. J. (2022) · Nature Communications · doi:10.1038/s41467-022-30384-7 · Cited by 216
Biomedical Applications of Microfluidic Devices: A Review
Gharib, G., Bütün, İ., Muganlı, Z., Kozalak, G., Namlı, İ., Sarraf, S. S., Ahmadi, V. E., Toyran, E., van Wijnen, A. J., & Koşar, A. (2022) · Biosensors · doi:10.3390/bios12111023 · Cited by 215
Recent advances in microfluidic cell sorting systems
Shen, Y., Yalikun, Y., & Tanaka, Y. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.11.025 · Cited by 201
A Review of Circulating Tumour Cell Enrichment Technologies
Rushton, A. J., Nteliopoulos, G., Shaw, J. A., & Coombes, R. C. (2021) · Cancers · doi:10.3390/cancers13050970 · Cited by 197
Zhou, J., Kulasinghe, A., Bogseth, A., O’Byrne, K., Punyadeera, C., & Papautsky, I. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0045-6 · Cited by 196
Stoecklein, D., & Di Carlo, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05042 · Cited by 179
Mishra, A., Dubash, T. D., Edd, J. F., Jewett, M. K., Garre, S. G., Karabacak, N. M., Rabe, D. C., Mutlu, B. R., Walsh, J. R., Kapur, R., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2006388117 · Cited by 171
“However, the very high concentration of mononuclear cells in leukopaks precludes analysis of the entire leukapheresis product using standard CTC recovery techniques, and recent studies have analyzed only 5% of leukopaks (200 million cells), representing only a fivefold increase over the standard 10-mL tube of whole bl…”
BackgroundMethodInfluentialSelf-citationMicrofluidic technologies for circulating tumor cell isolation
Cho, H., Kim, J., Song, H., Sohn, K. Y., Jeon, M., & Han, K.-H. (2018) · The Analyst · doi:10.1039/c7an01979c · Cited by 167
Point-of-care sensors for the management of sepsis
Reddy, B., Hassan, U., Seymour, C., Angus, D. C., Isbell, T. S., White, K., Weir, W., Yeh, L., Vincent, A., & Bashir, R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0288-9 · Cited by 142
Bhagwat, N., Dulmage, K., Pletcher, C. H., Wang, L., DeMuth, W., Sen, M., Balli, D., Yee, S. S., Sa, S., Tong, F., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-23217-5 · Cited by 75
Metadata
- Authors
- Fachin, F., Spuhler, P., Martel-Foley, J. M., Edd, J. F., Barber, T. A., Walsh, J., Karabacak, M., Pai, V., Yu, M., Smith, K., Hwang, H., Yang, J., Shah, S., Yarmush, R., Sequist, L. V., Stott, S. L., Maheswaran, S., Haber, D. A., Kapur, R., & Toner, M.
- Venue
- Scientific Reports
- Published
- 2017-09-07
- Volume
- 7
- Issue
- 1
- Pages
- 10936-10936
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2752013568
- Cited by
- 171
- References
- 52
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.