The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Definition of Fiducial Points in the Normal Seismocardiogram
Open accessAbstract
The purpose of this work is to define fiducial points in the seismocardiogram (SCG) and to correlate them with physiological events identified in ultrasound images. For 45 healthy subjects the SCG and the electrocardiogram (ECG) were recorded simultaneously at rest. Immediately following the SCG and ECG recordings ultrasound images of the heart were also obtained at rest. For all subjects a mean SCG signal was calculated and all fiducial points (peaks and valleys) were identified and labeled in the same way across all signals. Eight physiologic events, including the valve openings and closings, were annotated from ultrasound as well and the fiducial points were correlated with those physiologic events. A total of 42 SCG signals were used in the data analysis. The smallest mean differences (±SD) between the eight events found in the ultrasound images and the fiducial points, together with their correlation coefficients (r) were: atrial systolic onset: −2 (±16) ms, r = 0.75 (p < 0.001); peak atrial inflow: 13 (±19) ms, r = 0.63 (p < 0.001); mitral valve closure: 4 (±11) ms, r = 0.71 (p < 0.01); aortic valve opening: −3 (±11) ms, r = 0.60 (p < 0.001); peak systolic outflow: 13 (±23) ms, r = 0.42 (p < 0.01); aortic valve closure: −5 (±12) ms, r = 0.94 (p < 0.001); mitral valve opening: −7 (±19) ms, r = 0.87 (p < 0.001) and peak early ventricular filling: −18 (±28 ms), r = 0.79 (p < 0.001). In conclusion eight physiologic events characterizeing the cardiac cycle, are associated with reproducible, well-defined fiducial points in the SCG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This result agrees with previous literature. [38,39]”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [39]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the AC is near the beginning of the first major minima of the second heart sound.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [39]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“the AO clearly corresponds to the first major peak of the first heart sound”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [39]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163
Seismocardiography: Past, present and future
Zanetti, J. M., & Tavakolian, K. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611170 · Cited by 152
Salerno, D. M., & Zanetti, J. M. (1990) · Cited by 123
Seismocardiography: a technique for recording precordial acceleration
Zanetti, J. M., & Salerno, D. M. (2002) · doi:10.1109/cbms.1991.128936 · Cited by 103
Automatic Annotation of Seismocardiogram With High-Frequency Precordial Accelerations
Khosrow-Khavar, F., Tavakolian, K., Blaber, A. P., Zanetti, J. M., Fazel-Rezai, R., & Menon, C. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2360156 · Cited by 91
THE MASS-MOVEMENTS OF THE CIRCULATION AS SHOWN BY A RECOIL CURVE
Henderson, Y. (1905) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1905.14.3.287 · Cited by 74
Seismocardiography: waveform identification and noise analysis
Zanetti, J. M., Poliac, M. O., & Crow, R. S. (2002) · Computers in cardiology · doi:10.1109/cic.1991.169042 · Cited by 62
Research works printed but not linked: 2
- Baevsky, R., Egorov, A. & Kazarian, L. Metodika seismokardiografii. Kardiologia 18, 87–89 (1964).
- Otto, Catherine M. Textbook of Clinical Echocardiography: Expert Consult - Online and Print, 4e. (Saunders, 2009).
Cited by
Sorted by citations
Contactless seismocardiography via deep learning radars
Ha, U., Assana, S., & Adib, F. (2020) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3372224.3419982 · Cited by 203
Wearable sensors and devices for real-time cardiovascular disease monitoring
Lin, J., Fu, R., Zhong, X., Yu, P., Tan, G., Li, W., Zhang, H., Li, Y., Zhou, L., & Ning, C. (2021) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2021.100541 · Cited by 169
Flexible sensors and machine learning for heart monitoring
Kwon, S. H., & Dong, L. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107632 · Cited by 99
Wearable Sensors for the Monitoring of Maternal Health—A Systematic Review
Alim, A., & Imtiaz, M. H. (2023) · Sensors · doi:10.3390/s23052411 · Cited by 89
Dehkordi, P., Khosrow-Khavar, F., Rienzo, M. D., Inan, O. T., Schmidt, S. E., Blaber, A. P., Sørensen, K., Struijk, J. J., Zakeri, V., Lombardi, P., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01057 · Cited by 82
Self-citationSieciński, S., Kostka, P., & Tkacz, E. (2020) · Sensors · doi:10.3390/s20164522 · Cited by 80
Rai, D., Thakkar, H. K., Rajput, S. S., Santamaría, J., Bhatt, C., & Roca, F. (2021) · Mathematics · doi:10.3390/math9182243 · Cited by 74
Gyrocardiography: A Review of the Definition, History, Waveform Description, and Applications
Sieciński, S., Kostka, P., & Tkacz, E. (2020) · Sensors · doi:10.3390/s20226675 · Cited by 73
Andreozzi, E., Gargiulo, G. D., Esposito, D., & Bifulco, P. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.725716 · Cited by 57
Chest-Worn Inertial Sensors: A Survey of Applications and Methods
Rahmani, M. H., Berkvens, R., & Weyn, M. (2021) · Sensors · doi:10.3390/s21082875 · Cited by 56
Enabling the assessment of trauma-induced hemorrhage via smart wearable systems
Zia, J. S., Kimball, J. P., Rolfes, C., Hahn, J., & Inan, O. T. (2020) · Science Advances · doi:10.1126/sciadv.abb1708 · Cited by 51
CardiacWave: A mmWave-based Scheme of Non-Contact and High-Definition Heart Activity Computing
Xu, C., Li, H., Li, Z., Zhang, H., Rathore, A. S., Chen, X., Wang, K., Huang, M.-C., & Xu, W. (2021) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3478127 · Cited by 49
Santucci, F., Presti, D. L., Massaroni, C., Schena, E., & Setola, R. (2022) · Sensors · doi:10.3390/s22155805 · Cited by 47
Rienzo, M. D., Rizzo, F., Isilay, Z. M., & Lombardi, P. (2020) · Sensors · doi:10.3390/s20030680 · Cited by 44
Bhattacharya, S., Nikbakht, M., Alden, A., Tan, P., Wang, J., Alhalimi, T. A., Kim, S., Wang, P., Tanaka, H., Tandon, A., et al. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202201284 · Cited by 42
Towards Automatic and Fast Annotation of Seismocardiogram Signals Using Machine Learning
Thakkar, H. K., & Sahoo, P. K. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2951068 · Cited by 41
Reducing the Impact of External Vibrations on Fiducial Point Detection in Seismocardiogram Signals
Lin, D. J., Kimball, J. P., Zia, J. S., Ganti, V. G., & Inan, O. T. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3090376 · Cited by 39
Centracchio, J., Andreozzi, E., Esposito, D., Gargiulo, G. D., & Bifulco, P. (2022) · Bioengineering · doi:10.3390/bioengineering9030089 · Cited by 34
A Clinical Method for Estimation of VO2max Using Seismocardiography
Sørensen, K., Poulsen, M. K., Karbing, D. S., Søgaard, P., Struijk, J. J., & Schmidt, S. E. (2020) · International Journal of Sports Medicine · doi:10.1055/a-1144-3369 · Cited by 31
Self-citationNon-contact heart vibration measurement using computer vision-based seismocardiography
Rahman, M. M., Cook, J., & Taebi, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-38607-7 · Cited by 28
Multichannel seismocardiography: an imaging modality for investigating heart vibrations
Munck, K., Sørensen, K., Struijk, J. J., & Schmidt, S. E. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abc0b7 · Cited by 27
Self-citationSieciński, S., Tkacz, E., & Kostka, P. (2023) · Sensors · doi:10.3390/s23042152 · Cited by 27
A Novel Adaptive Recursive Least Squares Filter to Remove the Motion Artifact in Seismocardiography
Yu, S., & Liu, S. (2020) · Sensors · doi:10.3390/s20061596 · Cited by 27
Respiratory-Induced Amplitude Modulation of Forcecardiography Signals
Centracchio, J., Andreozzi, E., Esposito, D., & Gargiulo, G. D. (2022) · Bioengineering · doi:10.3390/bioengineering9090444 · Cited by 25
Isilay, Z. M., Racca, V., Pezzano, A., Tavanelli, M., & Rienzo, M. D. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.825918 · Cited by 22
Hoffmann, B., Dehkordi, P., Khosrow-Khavar, F., Goswami, N., Blaber, A. P., & Tavakolian, K. (2022) · npj Microgravity · doi:10.1038/s41526-022-00206-7 · Cited by 22
Contactless, Battery-free, and Stretchable Wearable for Continuous Recording of Seismocardiograms
Hesar, M. E., Khan, D., Seyedsadrkhani, N. S., & Ingebrandt, S. (2020) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00768 · Cited by 22
Rienzo, M. D., Avolio, A., Rizzo, G., Zeybek, Z. M. I., & Cucugliato, L. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3101976 · Cited by 21
Real-Time Seismocardiogram Feature Extraction Using Adaptive Gaussian Mixture Models
Lin, D. J., Gazi, A. H., Kimball, J. P., Nikbakht, M. R., & Inan, O. T. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3273989 · Cited by 20
Validity and reliability of seismocardiography for the estimation of cardiorespiratory fitness
Hansen, M. T., Rømer, T., Højgaard, A., Husted, K. L. S., Sørensen, K., Schmidt, S. E., Dela, F., & Helge, J. W. (2023) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2023.08.020 · Cited by 19
Self-citationA Wavelet-Based Approach for Motion Artifact Reduction in Ambulatory Seismocardiography
Skoric, J., D’Mello, Y., & Plant, D. V. (2024) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2024.3368291 · Cited by 20
Identification of Human Breathing-States Using Cardiac-Vibrational Signal for m-Health Applications
Choudhary, T., Sharma, L. N., Bhuyan, M. K., & Bora, K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3025384 · Cited by 16
Delineation and Analysis of Seismocardiographic Systole and Diastole Profiles
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3007295 · Cited by 16
Correlation between diastolic seismocardiography variables and echocardiography variables
Agam, A., Søgaard, P., Kragholm, K. H., Jensen, A. S., Sørensen, K., Hansen, J., & Schmidt, S. E. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac043 · Cited by 14
Self-citationTime Domain And Frequency Domain Heart Rate Variability Analysis on Gyrocardiograms
Sieciński, S., Kostka, P., & Tkacz, E. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176052 · Cited by 14
Clustering of SCG Events Using Unsupervised Machine Learning
Gamage, P. T., Azad, M. K., Taebi, A., Sandler, R. H., & Mansy, H. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-36844-9_7 · Cited by 15
M2ECG: Wearable Mechanocardiograms to Electrocardiogram Estimation Using Deep Learning
Tapotee, M. I., Saha, P., Mahmud, S., Alqahtani, A., & Chowdhury, M. E. H. (2024) · IEEE Access · doi:10.1109/access.2024.3353463 · Cited by 13
Morra, S., Hossein, A., Gorlier, D., Rabineau, J., Chaumont, M., Migeotte, P., & van de Borne, P. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab4a6a · Cited by 13
A Unified Methodology for Heartbeats Detection in Seismocardiogram and Ballistocardiogram Signals
Mora, N., Cocconcelli, F., Matrella, G., & Ciampolini, P. (2020) · Computers · doi:10.3390/computers9020041 · Cited by 12
Seismocardiography-based detection of heartbeats for continuous monitoring of vital signs
Cocconcelli, F., Mora, N., Matrella, G., & Ciampolini, P. (2019) · Computer Science and Electronic Engineering Conference · doi:10.1109/ceec47804.2019.8974343 · Cited by 11
Heartbeat Detection in Seismocardiograms with Semantic Segmentation
Duraj, K. M., Sieciński, S., Doniec, R., Piaseczna, N., Kostka, P., & Tkacz, E. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871477 · Cited by 11
Accuracy of a Clinical Applicable Method for Prediction of VO2max Using Seismocardiography
Hansen, M. T., Husted, K. L. S., Fogelstrøm, M., Rømer, T., Schmidt, S. E., Sørensen, K., & Helge, J. W. (2022) · International Journal of Sports Medicine · doi:10.1055/a-2004-4669 · Cited by 10
Self-citationZia, J. S., Kimball, J. P., Rozell, C. J., & Inan, O. T. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3014040 · Cited by 10
Wajdan, A., Jahren, T. S., Villegas-Martínez, M., Khan, F. H., Halvorsen, P. S., Odland, H. H., Elle, O. J., Solberg, A. H. S., & Remme, E. W. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3181148 · Cited by 10
Synthetic seismocardiogram generation using a transformer-based neural network
Nikbakht, M. R., Gazi, A. H., Zia, J. S., An, S., Lin, D. J., Inan, O. T., & Kamaleswaran, R. (2023) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocad067 · Cited by 10
From video to vital signs: a new method for contactless multichannel seismocardiography
Rahman, M. M., Kakavand, B., Wurm, W. V., Holman, W. L., Movahed, M. R., & Taebi, A. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-024-00034-6 · Cited by 9
Analysis of Cardiac Vibration Signals Acquired From a Novel Implant Placed on the Gastric Fundus
Areiza-Laverde, H. J., Dopierala, C., Senhadji, L., Boucher, F. R., Guméry, P.-Y., & Hernandez, A. I. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.748367 · Cited by 9
Sang, B., Shokouhmand, A., Wen, H., Khan, S., Puma, J. A., Patel, A., Green, P., Ebadi, N., & Ayazi, F. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3280407 · Cited by 9
Zhang, L., Cai, P., Deng, Y., Lin, J., Wu, M., Xiao, Z., Chu, Z., Shi, Q., Ye, F., Hu, J., et al. (2021) · Annals of Translational Medicine · doi:10.21037/atm-21-5161 · Cited by 7
Driver Cardiovascular Disease Detection Using Seismocardiogram
Uskovas, G., Valinevičius, A., Žilys, M., Navikas, D., Frivaldský, M., Prauzek, M., Konecny, J., & Andriukaitis, D. (2022) · Electronics · doi:10.3390/electronics11030484 · Cited by 8
Zakeri, V., Tavakolian, K., Blaber, A. P., Bauer, E. P., Dehkordi, P., & Khosrow-Khavar, F. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab6f53 · Cited by 8
Gyrocardiography Unit for Non-Invasive Human Diseases Diagnosis
Михайлович, А. В., Анатольевич, Б. Н., Vyacheslav, U., Gruzevich, Y. K., Комарова, М. Н., Рулев, М. Е., & Evseeva, Y. (2020) · Saint Petersburg International Conference on Integrated Navigation Systems · doi:10.23919/icins43215.2020.9133891 · Cited by 8
Mann, A. J., Rahman, M. M., Vanga, V., Gamage, P. T., & Taebi, A. (2024) · Journal of Medical Devices · doi:10.1115/1.4066368 · Cited by 7
Modeling Consistent Dynamics of Cardiogenic Vibrations in Low-Dimensional Subspace
Zia, J. S., Kimball, J. P., Hersek, S., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2980979 · Cited by 7
Exploring the Impact of Sensor Location on Seismocardiography-Derived Cardiac Time Intervals
Mann, A. J., Gamage, P. T., Kakavand, B., & Taebi, A. (2023) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4063203 · Cited by 7
CardioID: Secure ECG-BCG Agnostic Interaction-Free Device Pairing
Zuo, S., Sigg, S., Nguyen, L. N., Beck, N., Jähne-Raden, N., & Wolf, M. C. (2022) · IEEE Access · doi:10.1109/access.2022.3226503 · Cited by 6
Seismocardiography and echocardiography: the correlation in the systolic complex
Kolind, C. M., Tange, A. B., Sten, S. T., Sonne, M. M. S., Agam, A., Søgaard, P., & Schmidt, S. E. (2024) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad6a67 · Cited by 6
Self-citationA Novel Seismocardiogram Mathematical Model for Simplified Adjustment of Adaptive Filter
Uskovas, G., Valinevičius, A., Žilys, M., Navikas, D., Frivaldský, M., Prauzek, M., Konecny, J., & Andriukaitis, D. (2022) · Electronics · doi:10.3390/electronics11152444 · Cited by 6
Comparison of Seismocardiography Based Heart Rate Measurement Method
Erfianto, B., Rizal, A., & Suryani, V. (2020) · Journal of Southwest Jiaotong University · doi:10.35741/issn.0258-2724.55.6.12 · Cited by 5
Seismocardiography as a tool for assessment of bi-ventricular pacing
Sørensen, K., Søgaard, P., Emerek, K. J. G., Jensen, A. S., Struijk, J. J., & Schmidt, S. E. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac94b2 · Cited by 5
Self-citationMechanocardiography detects improvement of systolic function caused by resynchronization pacing
Tokmak, F., Koivisto, T., Lahdenoja, O., Vasankari, T., Jaakkola, S., & Airaksinen, J. K. E. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad1197 · Cited by 6
Lai, Y.-P., & Zhang, Y. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3412668 · Cited by 7
Agam, A., Agam, A., Korsgaard, E., Haugstrup, T. Y., Kristensen, C. B., Møgelvang, R., Kragholm, K. H., Emerek, K. J. G., Søgaard, P., & Schmidt, S. E. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf037 · Cited by 4
Self-citationYu, S., Xie, A., Liu, Y., Guo, Y., & Wang, G. (2024) · Measurement · doi:10.1016/j.measurement.2024.115942 · Cited by 4
Sieciński, S., & Grzegorzek, M. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.108925 · Cited by 4
Yu, S., Song, Q., & Liu, S. (2020) · IEEE Access · doi:10.1109/access.2020.3013380 · Cited by 4
Rahman, M. M., & Taebi, A. (2023) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn58485.2023.10331617 · Cited by 4
Learning Seismocardiogram Beat Denoising Without Clean Data
Nikbakht, M. R., Lin, D. J., & Inan, O. T. (2023) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi58575.2023.10313428 · Cited by 4
Moscol-Albañil, I., Romano, C., Maiorana, E., Nusca, A., Ussia, G. P., Schena, E., & Massaroni, C. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3619668 · Cited by 3
Estimation of cardiorespiratory fitness in healthy using seismocardiography
Schmidt, S. E., Hansen, M. T., Karbing, D. S., Sørensen, K., Poulsen, M. K., Rømer, T., Struijk, J. J., Søgaard, P., & Helge, J. W. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-025-00053-x · Cited by 3
Self-citationNaufal, D., Pramudyo, M., Rajab, T. L. E., Setiawan, A. W., & Adiono, T. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00235-x · Cited by 3
Electro-Mechanical Data Fusion for Heart Health Monitoring
Yakut, K., Usman, M., Xue, W., Haas, F. M., Hirsh, R. A., Boothby, J., Zhao, X., & Petty, T. (2022) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi54592.2022.00057 · Cited by 3
Lee, H. Y., Jung, Y. H., Jeung, K. W., Lee, D. H., Lee, B. K., Jang, G. Y., Oh, T. I., Mamadjonov, N., & Heo, T. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.07.009 · Cited by 3
Skoric, J., D’Mello, Y., & Plant, D. V. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3561071 · Cited by 2
Sadhukhan, D., Saloux, É., Hodžić, A., Dorme, C., Fink, M., & Ing, R. K. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3577130 · Cited by 2
Influence of Sampling Frequency on the Symmetric Projection Attractor Reconstruction
Pilar, M. A. I. D., Romano, C., Pinnelli, M., Nusca, A., Ussia, G. P., Schena, E., & Massaroni, C. (2025) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot66048.2025.11122086 · Cited by 2
Seismocardiography-based estimation of hemodynamic parameters during submaximal ergometer test
Deoisres, S., Dumnin, S., Yuenyongchaiwat, K., & Thanawattano, C. (2025) · Physiological Measurement · doi:10.1088/1361-6579/ae091a · Cited by 2
Carleton, R. N., Teckchandani, T. A., Neary, J. P., Samayoa, J., Khoury, J. M. B., Maguire, K. Q., Krätzig, G. P., & Asmundson, G. J. G. (2025) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2025.10.044 · Cited by 2
Korsgaard, E., Agam, A., Søgaard, P., Emerek, K. J. G., Sørensen, K., Helge, J. W., Struijk, J. J., & Schmidt, S. E. (2025) · Frontiers in Digital Health · doi:10.3389/fdgth.2025.1699611 · Cited by 2
Self-citationOn the design and development of a handheld electrocardiogram device in a clinical setting
Zepeda-Echavarria, A., Arntz, N. C. M. R., Westra, A. H., van Schelven, L. J., Euwe, F. E., Noordmans, H. J., Vessies, M. B., van de Leur, R. R., Hassink, R. J., Wildbergh, T. X., et al. (2024) · Frontiers in Digital Health · doi:10.3389/fdgth.2024.1403457 · Cited by 2
Real-Time Autoregressive Forecast of Cardiac Features for Psychophysiological Applications
Yaldiz, C. O., Lin, D. J., Gazi, A. H., Cestero, G. I., Chen, C., Bracken, B. K., Winder, A., Lynn, S. K., Sameni, R., & Inan, O. T. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3546148 · Cited by 2
Heart Rate Measurement Based on Embedded Accelerometer in a Smartphone
Urzeniczok, M., Sieciński, S., & Kostka, P. (2022) · Advances in intelligent systems and computing · doi:10.1007/978-3-031-09135-3_37 · Cited by 2
Visualization of the Multichannel Seismocardiogram
Munck, K., Sørensen, K., Struijk, J. J., & Schmidt, S. E. (2019) · Computing in cardiology · doi:10.22489/cinc.2019.204 · Cited by 1
Self-citationChen, C., Lin, W., & Lee, M. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3322675 · Cited by 1
Hu, M., Yi, H., Yan, W., Ren, W., Wang, J., & Qi, F. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1727160 · Cited by 1
Time Bias Awareness in ECG-Based Multiple Source Data Matching
Albrecht, U., Lawin, D., Kühn, S., & Kulau, U. (2022) · Studies in health technology and informatics · doi:10.3233/shti220668 · Cited by 1
Heart Rate Measuring System using Accelerometer And Gyroscope Sensor in Android Smartphone
Williamsyah, B. M., Rizal, A., Wijaya, R., & Ziani, S. (2024) · International Conference of Science and Information Technology in Smart Administration (ICSINTESA) · doi:10.1109/icsintesa62455.2024.10748185 · Cited by 1
Cordero, R., Feuerstein, D., & Joubert, P.-Y. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101933 · Cited by 1
Using Seismocardiogram Mathematical Model for Simplified Adjustment of Adaptive Filter
Uskovas, G., & Valinevičius, A. (2022) · International Conference Electronics · doi:10.1109/ieeeconf55059.2022.9810385 · Cited by 1
Seismocardiography: Interpretation and Clinical Application
Sørensen, K. (2021) · doi:10.54337/aau451017905 · Cited by 1
Self-citationVisualization of the Multichannel Seismocardiogram
Munck, K., Struijk, J. J., Sørensen, K., & Schmidt, S. E. (2019) · doi:10.23919/cinc49843.2019.9005739
Self-citationKushagra, A., Dasgupta, U., Roychowdhury, S., Samanta, S., & Srivastava, S. (2022) · AIP Advances · doi:10.1063/5.0076791
Tetlow, N., Devendra, P., Waiting, J. F., Aresu, M., Glover, A., Rooms, M., Jhanji, S., & Milliken, D. (2025) · BJA Open · doi:10.1016/j.bjao.2025.100395
Towards the Design of a Real-Time Processing System for Forcecardiography Signals
Zacharelos, E., Andreozzi, E., Esposito, D., Giaquinto, M., & Napoli, E. (2025) · International Conference on Modern Circuits and Systems Technologies · doi:10.1109/mocast65744.2025.11083939
Hansen, M. T., Jensen, M. H., Nielsen, S. K., Petersen, C. S., Sæderup, R. G., Schmidt, S. E., Wolsk, E., Helge, J. W., & Lamberts, M. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf095
Self-citationEstimation of Cardiorespiratory Fitness in Military Applicants Using Seismocardiography
Rasmussen, L. S., Alstrup, A., Markussen, L., Lamberts, T., Neumann, C., & Lamberts, M. (2025) · Military Medicine · doi:10.1093/milmed/usaf511
Automatic Estimation of Cardiac Time Intervals using Combined SCG and ECG
Ahdy, S., Sandler, R. H., & Mansy, H. A. (2025) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb67169.2025.11345378
Wearable SENsor to Diagnose and Assess SEverity of Aortic Stenosis (SENSE-AS)
Srinivasan, A., Harake, L. E., Fernandez, E. D. T., Saleeb, J., Trueb, J. T., Flaherty, J. D., Sweis, R. N., Shah, S. J., Thomas, J. D., Narang, A., et al. (2026) · JACC Advances · doi:10.1016/j.jacadv.2026.102699
Subcutaneous Monitoring of Cardiac Activity for Chronically Implanted Medical Devices
Cordero, R. (2020) · doi:10.70675/609809caz0199z4fcfzbbaezd2bfec10103c · Cited by 3
Metadata
- Authors
- Sørensen, K., Schmidt, S. E., Jensen, A. S., Søgaard, P., & Struijk, J. J.
- Affiliations
- Aalborg University (DK)
- Aalborg University Hospital (DK)
- Corresponding author
- Sørensen, Kasper
- Venue
- Scientific Reports
- Published
- 2018-10-18
- Volume
- 8
- Issue
- 1
- Pages
- 15455-15455
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6193995
- OpenAlex
- W2896674935
- Cited by
- 111
- References
- 27
- Citations by year
- 2026: 13 · 2025: 17 · 2024: 8 · 2023: 14 · 2022: 20 · 2021: 11 · 2020: 22 · 2019: 6
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Update notices
- correction (2020-09-04)
- Open access
- gold
- doi.org
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- seismocardiogram, fiducial points, mitral valve closure, aortic valve closure, valve opening, echocardiography, electrocardiogram
- MeSH terms
- Adult, Aged, Aged, 80 and over, Diastole, Echocardiography, Electrocardiography, Heart Function Tests, Heart Valves, Humans, Image Processing, Computer-Assisted, Middle Aged, Myocardial Contraction, Reference Values, Signal Processing, Computer-Assisted, Systole, Vibration, Reproducibility of Results, Young Adult, Fiducial Markers, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review