The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Slow insertion of silicon probes improves the quality of acute neuronal recordings
Open accessAbstract
Neural probes designed for extracellular recording of brain electrical activity are traditionally implanted with an insertion speed between 1 µm/s and 1 mm/s into the brain tissue. Although the physical effects of insertion speed on the tissue are well studied, there is a lack of research investigating how the quality of the acquired electrophysiological signal depends on the speed of probe insertion. In this study, we used four different insertion speeds (0.002 mm/s, 0.02 mm/s, 0.1 mm/s, 1 mm/s) to implant high-density silicon probes into deep layers of the somatosensory cortex of ketamine/xylazine anesthetized rats. After implantation, various qualitative and quantitative properties of the recorded cortical activity were compared across different speeds in an acute manner. Our results demonstrate that after the slowest insertion both the signal-to-noise ratio and the number of separable single units were significantly higher compared with those measured after inserting probes at faster speeds. Furthermore, the amplitude of recorded spikes as well as the quality of single unit clusters showed similar speed-dependent differences. Post hoc quantification of the neuronal density around the probe track showed a significantly higher number of NeuN-labelled cells after the slowest insertion compared with the fastest insertion. Our findings suggest that advancing rigid probes slowly (~1 µm/s) into the brain tissue might result in less tissue damage, and thus in neuronal recordings of improved quality compared with measurements obtained after inserting probes with higher speeds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interneurons of the neocortical inhibitory system
Markram, H., Toledo-Rodriguez, M., Wang, Y., Gupta, A., Silberberg, G., & Wu, C. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1519 · Cited by 2,954
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Flow of cortical activity underlying a tactile decision in mice
Guo, Z. V., Li, N., Huber, D., Ophir, E., Gutnisky, D., Ting, J. T., Feng, G., & Svoboda, K. (2014) · Neuron · doi:10.1016/j.neuron.2013.10.020 · Cited by 715 · cited 3×
“O'Shea DJ and Shenoy KV (2018).”
InfluentialRelationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
Origins of choice-related activity in mouse somatosensory cortex
Yang, H., Kwon, S. E., Severson, K. S., & O'Connor, D. H. (2016) · Nature Neuroscience · doi:10.1038/nn.4183 · Cited by 180 · cited 1×
“…Etemadi et al., 2016 0.01 / 0.1 10 μm/s / 100 μm/s rat C bundles of parylene C coated platinum electrodes 54 Leiser and Moxon, 2006 0.01 / 0.1 10 μm/s / ~100 μm/s rat A epoxylite- insulated tungsten microelectrodes 55 Yang et al., 2016 0.01 / 0.05 - 0.1 10 μm/s / 50 -…”
InfluentialIn Vivo Penetration Mechanics and Mechanical Properties of Mouse Brain Tissue at Micrometer Scales
Sharp, A. A., Ortega, A. M., Restrepo, D., Curran-Everett, D., & Gall, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003261 · Cited by 157
The density difference between tissue and neural probes is a key factor for glial scarring
Lind, G., Linsmeier, C. E., & Schouenborg, J. (2013) · Scientific Reports · doi:10.1038/srep02942 · Cited by 102
Cited by
Survey of spiking in the mouse visual system reveals functional hierarchy
Siegle, J. H., Jia, X., Durand, S., Gale, S., Bennett, C., Graddis, N., Heller, G., Ramirez, T. K., Choi, H., Luviano, J. A., et al. (2021) · Nature · doi:10.1038/s41586-020-03171-x · Cited by 634
High-density single-unit human cortical recordings using the Neuropixels probe
Chung, J. E., Sellers, K. K., Leonard, M. K., Gwilliams, L., Xu, D., Dougherty, M. E., Kharazia, V., Metzger, S. L., Welkenhuysen, M., Dutta, B., et al. (2022) · Neuron · doi:10.1016/j.neuron.2022.05.007 · Cited by 126
Revisiting metabolic engineering strategies for microbial synthesis of oleochemicals
Yan, Q., & Pfleger, B. F. (2020) · Metabolic Engineering · doi:10.1016/j.ymben.2019.04.009 · Cited by 105
System for recording from multiple flexible polyimide neural probes in freely behaving animals
van Daal, R. J. J., Sun, J.-J., Ceyssens, F., Michon, F., Kraft, M., Puers, R., & Kloosterman, F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5e19 · Cited by 18
Metadata
- Authors
- Fiáth, R., Márton, A. L., Mátyás, F., Pinke, D., Márton, G., Tóth, K., & Ulbert, I.
- Venue
- Scientific Reports
- Published
- 2019-01-14
- Volume
- 9
- Issue
- 1
- Pages
- 111-111
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2910283844
- Cited by
- 167
- References
- 9
- FWCI
- 9.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Slow insertion of silicon probes improves the quality of acute neuronal recordings. https://app.cochat.ai/papers/10.1038/s41598-018-36816-z
- The paper
- Fiáth, R., Márton, A. L., Mátyás, F., Pinke, D., Márton, G., Tóth, K., & Ulbert, I. (2019). Slow insertion of silicon probes improves the quality of acute neuronal recordings. Scientific Reports. https://doi.org/10.1038/s41598-018-36816-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.