Slow insertion of silicon probes improves the quality of acute neuronal recordings
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Neural probes designed for extracellular recording of brain electrical activity are traditionally implanted with an insertion speed between 1 µm/s and 1 mm/s into the brain tissue. Although the physical effects of insertion speed on the tissue are well studied, there is a lack of research investigating how the quality of the acquired electrophysiological signal depends on the speed of probe insertion. In this study, we used four different insertion speeds (0.002 mm/s, 0.02 mm/s, 0.1 mm/s, 1 mm/s) to implant high-density silicon probes into deep layers of the somatosensory cortex of ketamine/xylazine anesthetized rats. After implantation, various qualitative and quantitative properties of the recorded cortical activity were compared across different speeds in an acute manner. Our results demonstrate that after the slowest insertion both the signal-to-noise ratio and the number of separable single units were significantly higher compared with those measured after inserting probes at faster speeds. Furthermore, the amplitude of recorded spikes as well as the quality of single unit clusters showed similar speed-dependent differences. Post hoc quantification of the neuronal density around the probe track showed a significantly higher number of NeuN-labelled cells after the slowest insertion compared with the fastest insertion. Our findings suggest that advancing rigid probes slowly (~1 µm/s) into the brain tissue might result in less tissue damage, and thus in neuronal recordings of improved quality compared with measurements obtained after inserting probes with higher speeds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interneurons of the neocortical inhibitory system
Markram, H., Toledo-Rodriguez, M., Wang, Y., Gupta, A., Silberberg, G., & Wu, C. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1519 · Cited by 2,954
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Hartigan, J. A., & Hartigan, P. M. (1985) · The Annals of Statistics · doi:10.1214/aos/1176346577 · Cited by 1,973
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Barthó, P., Hirase, H., Monconduit, L., Zugaro, M., Harris, K. D., & Buzsáki, G. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01170.2003 · Cited by 887
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Kilosort: realtime spike-sorting for extracellular electrophysiology with hundreds of channels
Pachitariu, M., Steinmetz, N., Kadir, S., Carandini, M., & Kenneth D., H. (2016) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/061481 · Cited by 740
Flow of cortical activity underlying a tactile decision in mice
Guo, Z. V., Li, N., Huber, D., Ophir, E., Gutnisky, D., Ting, J. T., Feng, G., & Svoboda, K. (2014) · Neuron · doi:10.1016/j.neuron.2013.10.020 · Cited by 715 · cited 3×
“O'Shea DJ and Shenoy KV (2018).”
InfluentialQuantitative measures of cluster quality for use in extracellular recordings
Schmitzer-Torbert, N., Jackson, J., Henze, D., Harris, K., & Redish, A. D. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2004.09.066 · Cited by 662
Laminar Structure of Spontaneous and Sensory-Evoked Population Activity in Auditory Cortex
Sakata, S., & Harris, K. D. (2009) · Neuron · doi:10.1016/j.neuron.2009.09.020 · Cited by 594
How Local Is the Local Field Potential?
Kajikawa, Y., & Schroeder, C. E. (2011) · Neuron · doi:10.1016/j.neuron.2011.09.029 · Cited by 590
On the Origin of the Extracellular Action Potential Waveform: A Modeling Study
Gold, C., Henze, D. A., Koch, C., & Buzsáki, G. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00979.2005 · Cited by 586
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Bjornsson, C. S., Oh, S. J., Al-Kofahi, Y. A., Lim, Y. J., Smith, K. L., Turner, J. N., De, S., Roysam, B., Shain, W., & Kim, S. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/002 · Cited by 330
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Improving data quality in neuronal population recordings
Harris, K. D., Quiroga, R. Q., Freeman, J., & Smith, S. L. (2016) · Nature Neuroscience · doi:10.1038/nn.4365 · Cited by 252
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Potter, K. A., Buck, A. C., Self, W. K., & Capadona, J. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046020 · Cited by 239
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
Origins of choice-related activity in mouse somatosensory cortex
Yang, H., Kwon, S. E., Severson, K. S., & O'Connor, D. H. (2016) · Nature Neuroscience · doi:10.1038/nn.4183 · Cited by 180 · cited 1×
“…Etemadi et al., 2016 0.01 / 0.1 10 μm/s / 100 μm/s rat C bundles of parylene C coated platinum electrodes 54 Leiser and Moxon, 2006 0.01 / 0.1 10 μm/s / ~100 μm/s rat A epoxylite- insulated tungsten microelectrodes 55 Yang et al., 2016 0.01 / 0.05 - 0.1 10 μm/s / 50 -…”
InfluentialTime Multiplexed Active Neural Probe with 1356 Parallel Recording Sites
Raducanu, B. C., Yazicioglu, R. F., Lopez, C. M., Ballini, M., Putzeys, J., Wang, S., Andrei, A., Rochus, V., Welkenhuysen, M., Helleputte, N. V., et al. (2017) · Sensors · doi:10.3390/s17102388 · Cited by 171
Self-citationIn Vivo Penetration Mechanics and Mechanical Properties of Mouse Brain Tissue at Micrometer Scales
Sharp, A. A., Ortega, A. M., Restrepo, D., Curran-Everett, D., & Gall, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003261 · Cited by 157
Acute human brain responses to intracortical microelectrode arrays: challenges and future prospects
Fernández, E., Greger, B., House, P. A., Aranda, I., Botella, C., Albisua, J., Soto-Sánchez, C., Alfaro, A., & Normann, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00024 · Cited by 141
Marking microelectrode penetrations with fluorescent dyes
DiCarlo, J. J., Lane, J. W., Hsiao, S. S., & Johnson, K. O. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00113-1 · Cited by 141
Jensen, W., Yoshida, K., & Hofmann, U. G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.872824 · Cited by 114
Invasive consequences of using micro-electrodes and microdialysis probes in the brain
Khan, A. S., & Michael, A. C. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)00908-7 · Cited by 113
The density difference between tissue and neural probes is a key factor for glial scarring
Lind, G., Linsmeier, C. E., & Schouenborg, J. (2013) · Scientific Reports · doi:10.1038/srep02942 · Cited by 102
Spatiotemporal pH dynamics following insertion of neural microelectrode arrays
Johnson, M. D., Kao, O. E., & Kipke, D. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.023 · Cited by 94
Fiáth, R., Raducanu, B. C., Musa, S., Andrei, A., López, C. M., Hoof, C. A. V., Ruther, P., Aarts, A. A. A., Horváth, D., & Ulbert, I. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.01.060 · Cited by 87
Self-citationWelkenhuysen, M., Andrei, A., Ameye, L., Eberle, W., & Nuttin, B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2166963 · Cited by 85
Barz, F., Livi, A., Lanzilotto, M., Maranesi, M., Bonini, L., Paul, O., & Ruther, P. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a90 · Cited by 65
A response surface model predicting the in vivo insertion behavior of micromachined neural implants
Andrei, A., Welkenhuysen, M., Nuttin, B., & Eberle, W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016005 · Cited by 58
Han, M., Manoonkitiwongsa, P. S., Wang, C. X., & McCreery, D. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2172440 · Cited by 58 · cited 2×
“…et al., 2014 20 20 mm/s rat C silicon-based planar microelectrode arrays 80 Lee et al., 2017 20 20 mm/s rat C silicon-based planar microelectrode arrays 81 Bai et al., 2000 200 - 1000 20 - 100 cm/s guinea pig A three-dimensional silicon microelectrode arrays 82 Han et al., 2012 1000 1 m/s cat…”
InfluentialComparative study on the insertion behavior of cerebral microprobes
Haj Hosseini, N., Hoffmann, R., Kisban, S., Stieglitz, T., Paul, O., & Ruther, P. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353391 · Cited by 55
Laminar analysis of the slow wave activity in the somatosensory cortex of anesthetized rats
Fiáth, R., Kerekes, B. P., Wittner, L., Tóth, K., Beregszászi, P., Horváth, D., & Ulbert, I. (2016) · European Journal of Neuroscience · doi:10.1111/ejn.13274 · Cited by 53
Self-citationDifferential representation of auditory categories between cell classes in primate auditory cortex
Tsunada, J., Lee, J. H., & Cohen, Y. E. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.232892 · Cited by 39
Magnetically Inserted Neural Electrodes: Tissue Response and Functional Lifetime
Dryg, I. D., Ward, M. P., Qing, K. Y., Mei, H., Schaffer, J. E., & Irazoqui, P. P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2399856 · Cited by 32 · cited 2×
“…Barrese et al., 2016 8000 - 10000 8 - 10 m/s monkey C silicon-based microelectrode array (Utah) 86 Ward et al., 2009 8300 ≥8.3 m/s rat C silicon-based microelectrode array (Utah) 87 Ward et al., 2009 8300 ≥8.3 m/s rat C iridium oxide microelectrode array (Utah) 88 Dryg et al., 2015 27800 ~27,8…”
InfluentialFiáth, R., Hofer, K. T., Csikós, V., Horváth, D., Nánási, T., Tóth, K., Pothof, F., Böhler, C., Asplund, M., Ruther, P., et al. (2018) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2017-0154 · Cited by 27
Self-citationSeidl, K., Torfs, T., Mazière, P. D., Dijck, G. V., Csercsa, R., Dombovári, B., Nurcahyo, Y., Ramirez, H., Hulle, M. M. V., Orban, G. A., et al. (2010) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.014 · Cited by 26
Self-citationKim, B., Gutierrez, C. A., & Meng, E. F. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2420043 · Cited by 19
Cited by
Survey of spiking in the mouse visual system reveals functional hierarchy
Siegle, J. H., Jia, X., Durand, S., Gale, S., Bennett, C., Graddis, N., Heller, G., Ramirez, T. K., Choi, H., Luviano, J. A., et al. (2021) · Nature · doi:10.1038/s41586-020-03171-x · Cited by 634
High-density single-unit human cortical recordings using the Neuropixels probe
Chung, J. E., Sellers, K. K., Leonard, M. K., Gwilliams, L., Xu, D., Dougherty, M. E., Kharazia, V., Metzger, S. L., Welkenhuysen, M., Dutta, B., et al. (2022) · Neuron · doi:10.1016/j.neuron.2022.05.007 · Cited by 126
Revisiting metabolic engineering strategies for microbial synthesis of oleochemicals
Yan, Q., & Pfleger, B. F. (2020) · Metabolic Engineering · doi:10.1016/j.ymben.2019.04.009 · Cited by 105
System for recording from multiple flexible polyimide neural probes in freely behaving animals
van Daal, R. J. J., Sun, J.-J., Ceyssens, F., Michon, F., Kraft, M., Puers, R., & Kloosterman, F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5e19 · Cited by 18
“Therefore, hyperdrives: (1) reduce surgery time as the electrodes can be lowered to the exact target area post-operatively, (2) enable slow insertion speeds which improve the quality of the neuronal recordings [38], (3) have the ability to correct for positional drift of electrodes that may occur over time enhancing t…”
Background
Metadata
- Authors
- Fiáth, R., Márton, A. L., Mátyás, F., Pinke, D., Márton, G., Tóth, K., & Ulbert, I.
- Venue
- Scientific Reports
- Published
- 2019-01-14
- Volume
- 9
- Issue
- 1
- Pages
- 111-111
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2910283844
- Cited by
- 167
- References
- 41
- FWCI
- 9.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.