Acoustic Sensing as a Novel Wearable Approach for Cardiac Monitoring at the Wrist
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper introduces the concept of using acoustic sensing over the radial artery to extract cardiac parameters for continuous vital sign monitoring. It proposes a novel measurement principle that allows detection of the heart sounds together with the pulse wave, an attribute not possible with existing photoplethysmography (PPG)-based methods for monitoring at the wrist. The validity of the proposed principle is demonstrated using a new miniature, battery-operated wearable device to sense the acoustic signals and a novel algorithm to extract the heart rate from these signals. The algorithm utilizes the power spectral analysis of the acoustic pulse signal to detect the S1 sounds and additionally, the K-means method to remove motion artifacts for an accurate heartbeat detection. It has been validated on a dataset consisting of 12 subjects with a data length of 6 hours. The results demonstrate an accuracy of 98.78%, mean absolute error of 0.28 bpm, limits of agreement between −1.68 and 1.69 bpm, and a correlation coefficient of 0.998 with reference to a state-of-the-art PPG-based commercial device. The results in this proof of concept study demonstrate the potential of this new sensing modality to be used as an alternative, or to complement existing methods, for continuous monitoring of heart rate at the wrist.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Analogue and digital signal processing methods are often applied to the captured waveforms to remove motion artefacts and improve the SNR; multisensor configurations can also be used for active noise-cancelling and localization by beamforming118,119.”
From End-to-end design of wearable sensors (2022) · cites this paper as [118]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Stahl, S. E., An, H.-S., Dinkel, D. M., Noble, J. M., & Lee, J.-M. (2016) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000106 · Cited by 276
Evaluation of wearable consumer heart rate monitors based on photopletysmography
Parak, J., & Korhonen, I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944419 · Cited by 148
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139
In-Ear Audio Wearable: Measurement of Heart and Breathing Rates for Health and Safety Monitoring
Martin, A., & Voix, J. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2720463 · Cited by 112
Kim, J. U., Lee, Y. J., Lee, J., & Kim, J. Y. (2015) · Evidence-Based Complementary and Alternative Medicine · doi:10.1155/2015/381634 · Cited by 31
Research works printed but not linked: 26
- Sharma, P., Imtiaz, S. A. & Rodriguez-Villegas, E. An algorithm for heart rate extraction from acoustic recordings at the neck. IEEE Transactions on Biomedical Engineering (2018). · DOI
- Thomas, S. S. et al. Biowatch: A noninvasive wrist-based blood pressure monitor that incorporates training techniques for posture and subject variability. IEEE journal of biomedical and health informatics 20, 1291–1300 (2016). · DOI · Paper page
- Cho, M.-C., Kim, J.-Y. & Cho, S. A bio-impedance measurement system for portable monitoring of heart rate and pulse wave velocity using small body area. In Circuits and Systems, 2009. ISCAS 2009. IEEE International Symposium on, 3106–3109 (IEEE, 2009). · DOI
- Kristiansen, N. K., Fleischer, J., Jensen, M., Andersen, K. S. & Nygaard, H. Design and evaluation of a handheld impedance plethysmograph for measuring heart rate variability. Medical and Biological Engineering and Computing 43, 516–521 (2005). · DOI
- Cadmus-Bertram, L., Gangnon, R., Wirkus, E. J., Thraen-Borowski, K. M. & Gorzelitz-Liebhauser, J. The accuracy of heart rate monitoring by some wrist-worn activity trackers. Annals of internal medicine 166, 610–612 (2017). · DOI · Paper page
- Jo, E., Lewis, K., Directo, D., Kim, M. J. & Dolezal, B. A. Validation of biofeedback wearables for photoplethysmographic heart rate tracking. Journal of sports science & medicine 15, 540 (2016).
- Kranjec, J., Beguš, S., Drnovšek, J. & Geršak, G. Novel methods for noncontact heart rate measurement: A feasibility study. IEEE transactions on instrumentation and measurement 63, 838–847 (2013). · DOI
- Sekine, M. & Maeno, K. Non-contact heart rate detection using periodic variation in doppler frequency. In 2011 IEEE Sensors Applications Symposium, 318–322 (IEEE, 2011). · doi:10.1109/sas.2011.5739803
- Wang, F.-K., Tang, M.-C., Su, S.-C. & Horng, T.-S. Wrist pulse rate monitor using self-injection-locked radar technology. Biosensors 6, 54 (2016). · DOI
- Will, C. et al. Radar-based heart sound detection. Scientific reports 8, 11551 (2018). · DOI · Paper page
- An, Y.-J. et al. Flexible non-constrained rf wrist pulse detection sensor based on array resonators. IEEE transactions on biomedical circuits and systems 10, 300–308 (2016). · DOI
- Almeida, V. et al. Piezoelectric probe for pressure waveform estimation in flexible tubes and its application to the cardiovascular system. Sensors and Actuators A: Physical 169, 217–226 (2011). · DOI
- Wang, X., Liu, Z. & Zhang, T. Flexible sensing electronics for wearable/attachable health monitoring. Small 13, 1602790 (2017). · DOI · Paper page
- Lazareck, L. J. & Moussavi, Z. M. Classification of normal and dysphagic swallows by acoustical means. IEEE Transactions on Biomedical Engineering 51, 2103–2112 (2004). · DOI · Paper page
- Lanata, A., Scilingo, E. P. & De Rossi, D. A multimodal transducer for cardiopulmonary activity monitoring in emergency. IEEE Transactions on Information Technology in Biomedicine 14, 817–825 (2009). · DOI
- Walsh, S. & King, E. Pulse Diagnosis E-Book: A Clinical Guide (Elsevier Health Sciences, 2007).
- Grabowski, S. R. & Tortora, G. J. Principles of anatomy and physiology (Wiley, 2000).
- Shi, W. & Chiao, J.-C. Neural network based real-time heart sound monitor using a wireless wearable wrist sensor. Analog Integrated Circuits and Signal Processing 94, 383–393 (2018). · DOI
- Altman, D. G. & Bland, J. M. Standard deviations and standard errors. Bmj 331, 903 (2005). · DOI · Paper page
- Kühnel, W. & Hess, G. Micromachined subminiature condenser microphones in silicon. Sensors and Actuators A: Physical 32, 560–564 (1992). · doi:10.1016/0924-4247(92)80044-4
- Kabir, A. et al. High sensitivity acoustic transducers with thin p+ membranes and gold back-plate. Sensors and Actuators A: Physical 78, 138–142 (1999). · doi:10.1016/s0924-4247(99)00242-3
- Ganji, B. A. & Majlis, B. Y. Design and fabrication of a new mems capacitive microphone using a perforated aluminum diaphragm. Sensors and Actuators A: Physical 149, 29–37 (2009). · doi:10.1016/j.sna.2008.09.017
- Rodriguez-Villegas, E., Chen, G., Radcliffe, J. & Duncan, J. A pilot study of a wearable apnoea detection device. BMJ open 4, e005299 (2014). · DOI · Paper page
- Lloyd, S. Least squares quantization in pcm. IEEE transactions on information theory 28, 129–137 (1982). · DOI · Paper page
- Kohler, B.-U., Hennig, C. & Orglmeister, R. The principles of software qrs detection. IEEE Engineering in Medicine and biology Magazine 21, 42–57 (2002). · DOI · Paper page
- Pahlm, O. & Sörnmo, L. Software qrs detection in ambulatory monitoring—a review. Medical and Biological Engineering and Computing 22, 289–297 (1984). · DOI · Paper page
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
A review on flexible wearables – Recent developments in non-invasive continuous health monitoring
Kazanskiy, N. L., Khonina, S. N., & Butt, M. A. (2024) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2023.114993 · Cited by 196
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 187
Biosensors Based on Mechanical and Electrical Detection Techniques
Chalklen, T., Jing, Q., & Kar-Narayan, S. (2020) · Sensors · doi:10.3390/s20195605 · Cited by 133
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
Metadata
- Authors
- Sharma, P., Imtiaz, S. A., & Rodriguez-Villegas, E.
- ORCID
- Sharma, Piyush
- Venue
- Scientific Reports
- Published
- 2019-12-27
- Volume
- 9
- Issue
- 1
- ISSN
- 2045-2322
- Cited by
- 47
- References
- 10
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.