Standardization of brain MR images across machines and protocols: bridging the gap for MRI-based radiomics
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Radiomics relies on the extraction of a wide variety of quantitative image-based features to provide decision support. Magnetic resonance imaging (MRI) contributes to the personalization of patient care but suffers from being highly dependent on acquisition and reconstruction parameters. Today, there are no guidelines regarding the optimal pre-processing of MR images in the context of radiomics, which is crucial for the generalization of published image-based signatures. This study aims to assess the impact of three different intensity normalization methods (Nyul, WhiteStripe, Z-Score) typically used in MRI together with two methods for intensity discretization (fixed bin size and fixed bin number). The impact of these methods was evaluated on first- and second-order radiomics features extracted from brain MRI, establishing a unified methodology for future radiomics studies. Two independent MRI datasets were used. The first one (DATASET1) included 20 institutional patients with WHO grade II and III gliomas who underwent post-contrast 3D axial T1-weighted (T1w-gd) and axial T2-weighted fluid attenuation inversion recovery (T2w-flair) sequences on two different MR devices (1.5 T and 3.0 T) with a 1-month delay. Jensen–Shannon divergence was used to compare pairs of intensity histograms before and after normalization. The stability of first-order and second-order features across the two acquisitions was analysed using the concordance correlation coefficient and the intra-class correlation coefficient. The second dataset (DATASET2) was extracted from the public TCIA database and included 108 patients with WHO grade II and III gliomas and 135 patients with WHO grade IV glioblastomas. The impact of normalization and discretization methods was evaluated based on a tumour grade classification task (balanced accuracy measurement) using five well-established machine learning algorithms. Intensity normalization highly improved the robustness of first-order features and the performances of subsequent classification models. For the T1w-gd sequence, the mean balanced accuracy for tumour grade classification was increased from 0.67 (95% CI 0.61–0.73) to 0.82 (95% CI 0.79–0.84, P = .006), 0.79 (95% CI 0.76–0.82, P = .021) and 0.82 (95% CI 0.80–0.85, P = .005), respectively, using the Nyul, WhiteStripe and Z-Score normalization methods compared to no normalization. The relative discretization makes unnecessary the use of intensity normalization for the second-order radiomics features. Even if the bin number for the discretization had a small impact on classification performances, a good compromise was obtained using the 32 bins considering both T1w-gd and T2w-flair sequences. No significant improvements in classification performances were observed using feature selection. A standardized pre-processing pipeline is proposed for the use of radiomics in MRI of brain tumours. For models based on first- and second-order features, we recommend normalizing images with the Z-Score method and adopting an absolute discretization approach. For second-order feature-based signatures, relative discretization can be used without prior normalization. In both cases, 32 bins for discretization are recommended. This study may pave the way for the multicentric development and validation of MR-based radiomics biomarkers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Adjusting batch effects in microarray expression data using empirical Bayes methods
Johnson, W. E., Li, C., & Rabinovic, A. (2007) · Biostatistics · doi:10.1093/biostatistics/kxj037 · Cited by 8,658
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Computational Radiomics System to Decode the Radiographic Phenotype
(2017) · doi:10.1158/0008-5472.can-17-0339 · Cited by 6,593
N4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Divergence measures based on the Shannon entropy
Lin, J. (1991) · IEEE Transactions on Information Theory · doi:10.1109/18.61115 · Cited by 5,140
The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository
Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., Moore, S., Phillips, S., Maffitt, D., Pringle, M., et al. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-013-9622-7 · Cited by 4,599
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Bakas, S., Akbari, H., Sotiras, A., Bilello, M., Rozycki, M., Kirby, J. S., Freymann, J. B., Farahani, K., & Davatzikos, C. (2017) · Scientific Data · doi:10.1038/sdata.2017.117 · Cited by 3,049
The Balanced Accuracy and Its Posterior Distribution
Brodersen, K. H., Ong, C. S., Stephan, K. E., & Buhmann, J. M. (2010) · 2010 20th International Conference on Pattern Recognition · doi:10.1109/icpr.2010.764 · Cited by 1,816
Sun, R., Limkin, E. J., Vakalopoulou, M., Dercle, L., Champiat, S., Han, S. R., Verlingue, L., Brandao, D., Lancia, A., Ammari, S., et al. (2018) · The Lancet Oncology · doi:10.1016/s1470-2045(18)30413-3 · Cited by 1,236
Self-citationApplications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Unravelling the Role of O-glycans in Influenza A Virus Infection
Mayr, J., Lau, K., Lai, J. C. C., Gagarinov, I. A., Shi, Y., McAtamney, S., Chan, R. W. Y., Nicholls, J., von Itzstein, M., & Haselhorst, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-34175-3 · Cited by 1,069
Vallières, M., Freeman, C. R., Skamene, S. R., & El Naqa, I. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5471 · Cited by 897
Limkin, E. J., Sun, R., Dercle, L., Zacharaki, E. I., Robert, C., Reuzé, S., Schernberg, A., Paragios, N., Deutsch, E., & Ferté, C. (2017) · Annals of Oncology · doi:10.1093/annonc/mdx034 · Cited by 757
Self-citationTixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels
Shafiq‐ul‐Hassan, M., Zhang, G. G., Latifi, K., Ullah, G., Hunt, D. C., Balagurunathan, Y., Abdalah, M. A., Schabath, M. B., Goldgof, D. G., Mackin, D., et al. (2017) · Medical Physics · doi:10.1002/mp.12123 · Cited by 585
On standardizing the MR image intensity scale
Ny�l, L. G., & Udupa, J. K. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1072::aid-mrm11>3.0.co;2-m · Cited by 583
The SRI24 multichannel atlas of normal adult human brain structure
Rohlfing, T., Zahr, N. M., Sullivan, E. V., & Pfefferbaum, A. (2010) · Human Brain Mapping · doi:10.1002/hbm.20906 · Cited by 486
Leijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Statistical normalization techniques for magnetic resonance imaging
Shinohara, R. T., Sweeney, E. M., Goldsmith, J., Shiee, N., Mateen, F. J., Calabresi, P. A., Jarso, S., Pham, D. L., Reich, D. S., & Crainiceanu, C. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.08.008 · Cited by 425
Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics
Orlhac, F., Frouin, F., Nioche, C., Ayache, N., & Buvat, I. (2019) · Radiology · doi:10.1148/radiol.2019182023 · Cited by 411
A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET
Orlhac, F., Boughdad, S., Philippe, C., Stalla-Bourdillon, H., Nioche, C., Champion, L., Soussan, M., Frouin, F., Frouin, V., & Buvat, I. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.199935 · Cited by 393
Segmentation Labels for the Pre-operative Scans of the TCGA-LGG collection
Bakas, S., Akbari, H., Sotiras, A., Bilello, M., Rozycki, M., Kirby, J., Freymann, J., Farahani, K., & Davatzikos, C. (2017) · The Cancer Imaging Archive · doi:10.7937/k9/tcia.2017.gjq7r0ef · Cited by 290
Sources of intensity nonuniformity in spin echo images at 1.5 T
Simmons, A., Tofts, P. S., Barker, G. J., & Arridge, S. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320117 · Cited by 277
Radiomic MRI Phenotyping of Glioblastoma: Improving Survival Prediction
Bae, S., Choi, Y. S., Ahn, S. S., Chang, J. H., Kang, S.-G., Kim, E. H., Kim, S. H., & Lee, S.-K. (2018) · Radiology · doi:10.1148/radiol.2018180200 · Cited by 249
Liu, X., Li, Y., Qian, Z., Sun, Z., Xu, K., Wang, K., Liu, S., Fan, X., Li, S., Zhang, Z., et al. (2018) · NeuroImage: Clinical · doi:10.1016/j.nicl.2018.10.014 · Cited by 245
Repeatability of Multiparametric Prostate MRI Radiomics Features
Schwier, M., van Griethuysen, J., Vangel, M. G., Pieper, S., Peled, S., Tempany, C., Aerts, H. J. W. L., Kikinis, R., Fennessy, F. M., & Fedorov, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-45766-z · Cited by 237
Radiomics of Brain MRI: Utility in Prediction of Metastatic Tumor Type
Kniep, H. C., Madesta, F., Schneider, T., Hanning, U., Schönfeld, M. H., Schön, G., Fiehler, J., Gauer, T., Werner, R., & Gellissen, S. (2019) · Radiology · doi:10.1148/radiol.2018180946 · Cited by 237
Mayerhoefer, M. E., Szomolanyi, P., Jirak, D., Materka, A., & Trattnig, S. (2009) · Medical Physics · doi:10.1118/1.3081408 · Cited by 225
Evaluating the impact of intensity normalization on MR image synthesis
Reinhold, J. C., Dewey, B. E., Carass, A., & Prince, J. L. (2019) · Medical Imaging 2019: Image Processing · doi:10.1117/12.2513089 · Cited by 206
Gray-level discretization impacts reproducible MRI radiomics texture features
Duron, L., Balvay, D., Vande Perre, S., Bouchouicha, A., Savatovsky, J., Sadik, J.-C., Thomassin-Naggara, I., Fournier, L., & Lecler, A. (2019) · PLOS ONE · doi:10.1371/journal.pone.0213459 · Cited by 188
Radiomics in Glioblastoma: Current Status and Challenges Facing Clinical Implementation
Chaddad, A., Kucharczyk, M. J., Daniel, P., Sabri, S., Jean-Claude, B. J., Niazi, T., & Abdulkarim, B. (2019) · Frontiers in Oncology · doi:10.3389/fonc.2019.00374 · Cited by 184
Evaluating intensity normalization on MRIs of human brain with multiple sclerosis
Shah, M., Xiao, Y., Subbanna, N., Francis, S., Arnold, D. L., Collins, D. L., & Arbel, T. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.12.003 · Cited by 178
Moradmand, H., Aghamiri, S. M. R., & Ghaderi, R. (2020) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12795 · Cited by 173
Differentiation between glioblastoma, brain metastasis and subtypes using radiomics analysis
Artzi, M., Bressler, I., & Ben Bashat, D. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26643 · Cited by 165
Peng, L. C., Parekh, V. S., Huang, P., Lin, D. D. M., Sheikh, K., Baker, B. R., Kirschbaum, T., Silvestri, F., Son, J., Robinson, A., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.041 · Cited by 155
Rathore, S., Akbari, H., Rozycki, M., Abdullah, K. G., Nasrallah, M. P., Binder, Z. A., Davuluri, R. V., Lustig, R. A., Dahmane, N., Bilello, M., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22739-2 · Cited by 154
Sun, X., Shi, L., Luo, Y., Yang, W., Li, H., Liang, P., Li, K., Mok, V., Chu, C. W., & Wang, D. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0064-y · Cited by 144
Zhang, X., Tian, Q., Wang, L., Liu, Y., Li, B., Liang, Z., Gao, P., Zheng, K., Zhao, B.-F., & Lu, H. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25960 · Cited by 129
Um, H., Tixier, F., Bermudez, D., Deasy, J. O., Young, R. J., & Veeraraghavan, H. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab2f44 · Cited by 120
Su, X., Chen, N., Sun, H., Liu, Y., Yang, X., Wang, W., Zhang, S., Tan, Q., Su, J., Gong, Q., et al. (2019) · Neuro-Oncology · doi:10.1093/neuonc/noz184 · Cited by 119
Ford, J. C., Dogan, N., Young, L. A., & Yang, F. (2018) · Contrast Media & Molecular Imaging · doi:10.1155/2018/1729071 · Cited by 111
Antunes, J. T., Viswanath, S. E., Rusu, M., Valls, L., Hoimes, C. J., Avril, N. E., & Madabhushi, A. (2016) · Translational Oncology · doi:10.1016/j.tranon.2016.01.008 · Cited by 108
Zinn, P. O., Singh, S. K., Kotrotsou, A., Hassan, I., Thomas, G., Luedi, M. M., Elakkad, A., Elshafeey, N., Idris, T., Mosley, J., et al. (2018) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-17-3420 · Cited by 108
Wu, S., Meng, J., Yu, Q., Li, P., & Fu, S. (2019) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-018-2787-1 · Cited by 103
Imaging biomarker analysis of advanced multiparametric MRI for glioma grading
Vamvakas, A., Williams, S., Theodorou, K., Kapsalaki, E. Z., Fountas, K. N., Kappas, C., Vassiou, K. G., & Tsougos, I. (2019) · Physica Medica · doi:10.1016/j.ejmp.2019.03.014 · Cited by 103
Computer-Aided Grading of Gliomas Combining Automatic Segmentation and Radiomics
Chen, W., Liu, B., Peng, S., Sun, J., & Xu, Q. (2018) · International Journal of Biomedical Imaging · doi:10.1155/2018/2512037 · Cited by 102
Sanghani, P., Ang, B. T., King, N. K. K., & Ren, H. (2018) · Surgical Oncology · doi:10.1016/j.suronc.2018.09.002 · Cited by 91
Bologna, M., Corino, V., & Mainardi, L. T. (2019) · Medical Physics · doi:10.1002/mp.13834 · Cited by 77
Molina, D., Pérez-Beteta, J., Martínez‐González, A., Martino, J., Velásquez, C., Arana, E., & Pérez‐García, V. M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178843 · Cited by 70
Ortiz-Ramón, R., Hernández, M. V., González‐Castro, V., Makin, S., Armitage, P. A., Aribisala, B. S., Bastin, M. E., Deary, I. J., Wardlaw, J. M., & Moratal, D. (2019) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2019.02.006 · Cited by 64
Pintus, V., Baragona, A. J., Wieland, K., Schilling, M., Miklin-Kniefacz, S., Haisch, C., & Schreiner, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-55471-6 · Cited by 63
Dynamic behavior of suture-anastomosed arteries and implications to vascular surgery operations
Roussis, P. C., Giannakopoulos, A. E., Charalambous, H. P., Demetriou, D. C., & Georghiou, G. P. (2015) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-14-1 · Cited by 61
Lecler, A., Duron, L., Balvay, D., Savatovsky, J., Bergès, O., Zmuda, M., Farah, E., Galatoire, O., Bouchouicha, A., & Fournier, L. S. (2019) · Scientific Reports · doi:10.1038/s41598-018-37984-8 · Cited by 60
Tixier, F., Um, H., Bermudez, D. H., Iyer, A., Apte, A., Graham, M. S., Nevel, K. S., Deasy, J. O., Young, R. J., & Veeraraghavan, H. (2019) · Oncotarget · doi:10.18632/oncotarget.26578 · Cited by 52
Reliability of tumor segmentation in glioblastoma: Impact on the robustness of MRI‐radiomic features
Tixier, F., Um, H., Young, R. J., & Veeraraghavan, H. (2019) · Medical Physics · doi:10.1002/mp.13624 · Cited by 51
Chirra, P. V., Bloch, B., Rastinehad, A. R., Purysko, A. S., Madabhushi, A., Viswanath, S. E., Leo, P., Yim, M. C., & Rosen, M. A. (2018) · SPIE Medical Imaging: Computer-Aided Diagnosis · doi:10.1117/12.2293992 · Cited by 34
Establishment and ultrasound characteristics of atherosclerosis in rhesus monkey
Zeng, W., Wen, X., Gong, L., Sun, J., Yang, J., Liao, J., Qian, C., Chen, W., Song, B., & Gao, F. (2015) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-14-s1-s13 · Cited by 32
Palumbo, D., Yee, B., O'Dea, P., Leedy, S., Viswanath, S. E., & Madabhushi, A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091258 · Cited by 31
Imaging of gliomas at 1.5 and 3 Tesla - A comparative study
Tselikas, L., Souillard-Scémama, R., Naggara, O. N., Mellerio, C., Varlet, P., Dezamis, E., Dômont, J., Dhermain, F. G., Devaux, B. C., Chrétien, F. C., et al. (2014) · Neuro-Oncology · doi:10.1093/neuonc/nou332 · Cited by 20
Self-citationMulti-stage Association Analysis of Glioblastoma Gene Expressions with Texture and Spatial Patterns
Elsheikh, S. S. M., Bakas, S., Mulder, N., Chimusa, E. R., Davatzikos, C. A., & Crimi, A. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-11723-8_24 · Cited by 15
Liu, H., Jiang, H., Wang, X., Zheng, J., Zhao, H., Cheng, Y., Tao, X., Wang, M., Liu, C., Huang, T., et al. (2019) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2019.04.04 · Cited by 8
Cited by
Radiomics, machine learning, and artificial intelligence—what the neuroradiologist needs to know
Wagner, M. W., Namdar, K., Biswas, A., Monah, S., Khalvati, F., & Ertl-Wagner, B. B. (2021) · Neuroradiology · doi:10.1007/s00234-021-02813-9 · Cited by 165
Image annotation and curation in radiology: an overview for machine learning practitioners
Galbusera, F., & Cina, A. (2024) · European Radiology Experimental · doi:10.1186/s41747-023-00408-y · Cited by 62
Bakas, S., Vollmuth, P., Galldiks, N., Booth, T. C., Aerts, H. J. W. L., Bi, W. L., Wiestler, B., Tiwari, P., Pati, S., Baid, U., et al. (2024) · The Lancet Oncology · doi:10.1016/s1470-2045(24)00315-2 · Cited by 36
Minimising multi-centre radiomics variability through image normalisation: a pilot study
Campello, V. M., Martín-Isla, C., Izquierdo, C., Guala, A., Palomares, J. F. R., Viladés, D., Descalzo, M. L., Karakas, M., Çavuş, E., Raisi-Estabragh, Z., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-16375-0 · Cited by 24
Metadata
- Authors
- Carré, A., Klausner, G., Edjlali, M., Lerousseau, M., Briend-Diop, J., Sun, R., Ammari, S., Reuzé, S., Alvarez Andres, E., Estienne, T., Niyoteka, S., Battistella, E., Vakalopoulou, M., Dhermain, F., Paragios, N., Deutsch, E., Oppenheim, C., Pallud, J., & Robert, C.
- Venue
- Scientific Reports
- Published
- 2020-07-23
- Volume
- 10
- Issue
- 1
- Pages
- 12340-12340
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3045086986
- Cited by
- 278
- References
- 65
- FWCI
- 17.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.