Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper reports a highly sensitive, non-invasive sensor for real-time glucose monitoring from interstitial fluid. The structure is comprised of a chip-less tag sensor which may be taped over the patient’s skin and a reader, that can be embedded in a smartwatch. The tag sensor is energized through the established electromagnetic coupling between the tag and the reader and its frequency response is reflected on the spectrum of the reader in the same manner. The tag sensor consumes zero power as there is no requirement for any active readout or communication circuitry on the tag side. When measuring changes in glucose concentrations within saline replicating interstitial fluid, the sensor was able to detect glucose with an accuracy of ~ 1 mM/l over a physiological range of glucose concentrations with 38 kHz of the resonance frequency shift. This high sensitivity is attained as a result of the proposed new design and extended field concentration on the tag. The impact of some of the possible interferences on the response of the sensor’s performance was also investigated. Variations in electrolyte concentrations within the test samples have a negligible effect on the response of the sensor unless these variations are supra-physiologically large.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In situ click chemistry generation of cyclooxygenase-2 inhibitors
Bhardwaj, A., Kaur, J., Wuest, M., & Wuest, F. (2017) · Nature Communications · doi:10.1038/s41467-016-0009-6 · Cited by 7,448
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 586
Nocturnal Glucose Control with an Artificial Pancreas at a Diabetes Camp
Phillip, M., Battelino, T., Atlas, E., Kordonouri, O., Bratina, N., Miller, S., Biester, T., Avbelj Stefanija, M., Muller, I., Nimri, R., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1206881 · Cited by 435
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Research works printed but not linked: 14
- Baghelani, M., Abbasi, Z. & Daneshmand, M. Noncontact high sensitivity chipless tag microwave resonator for bitumen concentration measurement at high temperatures. Fuel 265, 116916 (2020). · doi:10.1016/j.fuel.2019.116916
- Liu, W., Yang, X., Niu, Y. & Sun, H. Improve planar multiple split-ring resonator sensor for microwave detection applications. Sens. Actuator A- Phys. 297, 111542 (2019). · doi:10.1016/j.sna.2019.111542
- Tsai, T. T. et al. High throughput and label-free particle sensor based on microwave resonators. Sens. Actuator A- Phys. 285, 652–658 (2019). · doi:10.1016/j.sna.2018.12.008
- Benlamri, M. et al. Planar microwave resonator with electrodeposited ZnO thin film for ultraviolet detection. Semicond. Sci. Technol. 35(2), 025003 (2019). · doi:10.1088/1361-6641/ab5924
- Jha, A. K., Delmonte, N., Lamecki, A., Mrozowski, M. & Bozzi, M. Design of microwave-based angular displacement sensor. IEEE Microw. Wirel. Co. 29(4), 306–308 (2019). · doi:10.1109/lmwc.2019.2899490
- Nosrati, M., Abbasi, Z., Baghelani, M., Bhadra, S. & Daneshmand, M. Locally strong-coupled microwave resonator using PEMC boundary for distant sensing applications. IEEE Trans. Microw. Theory. 67(10), 4130–4139 (2019). · doi:10.1109/tmtt.2019.2931555
- Camli, B. et al. A microwave ring resonator based glucose sensor. Proc. Eng. 168, 465–468 (2016). · doi:10.1016/j.proeng.2016.11.127
- Bahar, A. A. M. et al. Real time microwave biochemical sensor based on circular SIW approach for aqueous dielectric detection. Sci. Rep.-UK 9(1), 5467 (2019). · doi:10.1038/s41598-019-41702-3
- Kapilevich, B. & Litvak, B. Optimized microwave sensor for online concentration measurements of binary liquid mixtures. IEEE Sens. J. 11(10), 2611–2616 (2011). · doi:10.1109/jsen.2011.2149517
- Aezinia, F. & Bahreyni, B. An interface circuit with wide dynamic range for differential capacitive sensing applications. IEEE Trans. Circuits II. 60(11), 766–770 (2013).
- Yang, C. L., Lee, C. S., Chen, K. W. & Chen, K. Z. Noncontact measurement of complex permittivity and thickness by using planar resonators. IEEE Trans. Microw. Theory 64(1), 247–257 (2015). · doi:10.1109/tmtt.2015.2503764
- Kumari, R., Patel, P. N. & Yadav, R. An ENG resonator-based microwave sensor for the characterization of aqueous glucose. J. Phys. D Appl. Phys. 51(7), 075601 (2018). · doi:10.1088/1361-6463/aaa5c5
- Govind, G. & Akhtar, M. J. Metamaterial-inspired microwave microfluidic sensor for glucose monitoring in aqueous solutions. IEEE Sens. J. 19(24), 11900–11907 (2019). · doi:10.1109/jsen.2019.2938853
- Diem, K. & Lentner, C. Blood-Inorganic Substances. Documents Geigy Scientific Tables 565 (Ciba-Geigy Limited, Basle, 1970).
Cited by
Lee, I., Probst, D., Klonoff, D., & Sode, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113054 · Cited by 288
Noninvasive Glucose Sensing in Aqueous Solutions Using an Active Split-Ring Resonator
Abdolrazzaghi, M., Katchinskiy, N., Elezzabi, A. Y., Light, P. E., & Daneshmand, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3090050 · Cited by 207
Self-citationPullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Metadata
- Authors
- Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E.
- Venue
- Scientific Reports
- Published
- 2020-07-31
- Volume
- 10
- Issue
- 1
- Pages
- 12980-12980
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3046853010
- Cited by
- 214
- References
- 46
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- Alberta Diabetes Institute
- Natural Sciences and Engineering Research Council of Canada
- FESRI
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.