CoChat

Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators

Open access
Baghelani, Masoud, Abbasi, Zahra, Daneshmand, Mojgan, Light, Peter E. · 2020 · Scientific Reports
Cited by 214

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

This paper reports a highly sensitive, non-invasive sensor for real-time glucose monitoring from interstitial fluid. The structure is comprised of a chip-less tag sensor which may be taped over the patient’s skin and a reader, that can be embedded in a smartwatch. The tag sensor is energized through the established electromagnetic coupling between the tag and the reader and its frequency response is reflected on the spectrum of the reader in the same manner. The tag sensor consumes zero power as there is no requirement for any active readout or communication circuitry on the tag side. When measuring changes in glucose concentrations within saline replicating interstitial fluid, the sensor was able to detect glucose with an accuracy of ~ 1 mM/l over a physiological range of glucose concentrations with 38 kHz of the resonance frequency shift. This high sensitivity is attained as a result of the proposed new design and extended field concentration on the tag. The impact of some of the possible interferences on the response of the sensor’s performance was also investigated. Variations in electrolyte concentrations within the test samples have a negligible effect on the response of the sensor unless these variations are supra-physiologically large.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-020-69547-1

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 14

  1. Baghelani, M., Abbasi, Z. & Daneshmand, M. Noncontact high sensitivity chipless tag microwave resonator for bitumen concentration measurement at high temperatures. Fuel 265, 116916 (2020). · doi:10.1016/j.fuel.2019.116916
  2. Liu, W., Yang, X., Niu, Y. & Sun, H. Improve planar multiple split-ring resonator sensor for microwave detection applications. Sens. Actuator A- Phys. 297, 111542 (2019). · doi:10.1016/j.sna.2019.111542
  3. Tsai, T. T. et al. High throughput and label-free particle sensor based on microwave resonators. Sens. Actuator A- Phys. 285, 652–658 (2019). · doi:10.1016/j.sna.2018.12.008
  4. Benlamri, M. et al. Planar microwave resonator with electrodeposited ZnO thin film for ultraviolet detection. Semicond. Sci. Technol. 35(2), 025003 (2019). · doi:10.1088/1361-6641/ab5924
  5. Jha, A. K., Delmonte, N., Lamecki, A., Mrozowski, M. & Bozzi, M. Design of microwave-based angular displacement sensor. IEEE Microw. Wirel. Co. 29(4), 306–308 (2019). · doi:10.1109/lmwc.2019.2899490
  6. Nosrati, M., Abbasi, Z., Baghelani, M., Bhadra, S. & Daneshmand, M. Locally strong-coupled microwave resonator using PEMC boundary for distant sensing applications. IEEE Trans. Microw. Theory. 67(10), 4130–4139 (2019). · doi:10.1109/tmtt.2019.2931555
  7. Camli, B. et al. A microwave ring resonator based glucose sensor. Proc. Eng. 168, 465–468 (2016). · doi:10.1016/j.proeng.2016.11.127
  8. Bahar, A. A. M. et al. Real time microwave biochemical sensor based on circular SIW approach for aqueous dielectric detection. Sci. Rep.-UK 9(1), 5467 (2019). · doi:10.1038/s41598-019-41702-3
  9. Kapilevich, B. & Litvak, B. Optimized microwave sensor for online concentration measurements of binary liquid mixtures. IEEE Sens. J. 11(10), 2611–2616 (2011). · doi:10.1109/jsen.2011.2149517
  10. Aezinia, F. & Bahreyni, B. An interface circuit with wide dynamic range for differential capacitive sensing applications. IEEE Trans. Circuits II. 60(11), 766–770 (2013).
  11. Yang, C. L., Lee, C. S., Chen, K. W. & Chen, K. Z. Noncontact measurement of complex permittivity and thickness by using planar resonators. IEEE Trans. Microw. Theory 64(1), 247–257 (2015). · doi:10.1109/tmtt.2015.2503764
  12. Kumari, R., Patel, P. N. & Yadav, R. An ENG resonator-based microwave sensor for the characterization of aqueous glucose. J. Phys. D Appl. Phys. 51(7), 075601 (2018). · doi:10.1088/1361-6463/aaa5c5
  13. Govind, G. & Akhtar, M. J. Metamaterial-inspired microwave microfluidic sensor for glucose monitoring in aqueous solutions. IEEE Sens. J. 19(24), 11900–11907 (2019). · doi:10.1109/jsen.2019.2938853
  14. Diem, K. & Lentner, C. Blood-Inorganic Substances. Documents Geigy Scientific Tables 565 (Ciba-Geigy Limited, Basle, 1970).

Cited by

See all 214

Metadata

Authors
Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E.
Venue
Scientific Reports
Published
2020-07-31
Volume
10
Issue
1
Pages
12980-12980
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3046853010
Cited by
214
References
46
FWCI
9.03
Type
journal article
Language
en
Open access
gold
Licence
Funders
  • Alberta Diabetes Institute
  • Natural Sciences and Engineering Research Council of Canada
  • FESRI

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.