Coculture with hiPS-derived intestinal cells enhanced human hepatocyte functions in a pneumatic-pressure-driven two-organ microphysiological system
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Examining intestine–liver interactions is important for achieving the desired physiological drug absorption and metabolism response in in vitro drug tests. Multi-organ microphysiological systems (MPSs) constitute promising tools for evaluating inter-organ interactions in vitro. For coculture on MPSs, normal cells are challenging to use because they require complex maintenance and careful handling. Herein, we demonstrated the potential of coculturing normal cells on MPSs in the evaluation of intestine–liver interactions. To this end, we cocultured human-induced pluripotent stem cell-derived intestinal cells and fresh human hepatocytes which were isolated from PXB mice with medium circulation in a pneumatic-pressure-driven MPS with pipette-friendly liquid-handling options. The cytochrome activity, albumin production, and liver-specific gene expressions in human hepatocytes freshly isolated from a PXB mouse were significantly upregulated via coculture with hiPS-intestinal cells. Our normal cell coculture shows the effects of the interactions between the intestine and liver that may occur in vivo. This study is the first to demonstrate the coculturing of hiPS-intestinal cells and fresh human hepatocytes on an MPS for examining pure inter-organ interactions. Normal-cell coculture using the multi-organ MPS could be pursued to explore unknown physiological mechanisms of inter-organ interactions in vitro and investigate the physiological response of new drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Fujii, M., Matano, M., Toshimitsu, K., Takano, A., Mikami, Y., Nishikori, S., Sugimoto, S., & Sato, T. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.11.016 · Cited by 558
Recent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Kidambi, S., Yarmush, R. S., Novik, E., Chao, P., Yarmush, M. L., & Nahmias, Y. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0906820106 · Cited by 213
van Midwoud, P. M., Merema, M. T., Verpoorte, E., & Groothuis, G. M. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00043d · Cited by 203
Chemical-PDMS binding kinetics and implications for bioavailability in microfluidic devices
Auner, A. W., Tasneem, K. M., Markov, D. A., McCawley, L. J., & Hutson, M. S. (2019) · Lab on a Chip · doi:10.1039/c8lc00796a · Cited by 87
Arakawa, H., Sugiura, S., Kawanishi, T., Shin, K., Toyoda, H., Satoh, T., Sakai, Y., Kanamori, T., & Kato, Y. (2020) · Lab on a Chip · doi:10.1039/c9lc00884e · Cited by 48
Self-citation
Cited by
Shinha, K., Nihei, W., Nakamura, H., Goto, T., Kawanishi, T., Ishida, N., Yamazaki, N., Imakura, Y., Mima, S., Inamura, K., et al. (2021) · Micromachines · doi:10.3390/mi12091007 · Cited by 36
“However, the trend of increased mRNA expression found in our previous studies using a different MPS was also observed in this study [39].”
ResultSelf-citationWang, L., Koui, Y., Kanegae, K., Kido, T., Tamura-Nakano, M., Yabe, S., Tai, K., Nakajima, Y., Kusuhara, H., Sakai, Y., et al. (2024) · Biomaterials · doi:10.1016/j.biomaterials.2024.122621 · Cited by 25
Self-citationKimura, H., Nakamura, H., Goto, T., Uchida, W., Uozumi, T., Nishizawa, D., Shinha, K., Sakagami, J., & Doi, K. (2024) · Lab on a Chip · doi:10.1039/d3lc00934c · Cited by 20
Self-citation
Metadata
- Authors
- Shinohara, M., Arakawa, H., Oda, Y., Shiraki, N., Sugiura, S., Nishiuchi, T., Satoh, T., Iino, K., Leo, S., Kato, Y., Araya, K., Kawanishi, T., Nakatsuji, T., Mitsuta, M., Inamura, K., Goto, T., Shinha, K., Nihei, W., Komori, K., Nishikawa, M., Kume, S., Kato, Y., Kanamori, T., Sakai, Y., & Kimura, H.
- Venue
- Scientific Reports
- Published
- 2021-03-08
- Volume
- 11
- Issue
- 1
- Pages
- 5437-5437
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3135131086
- Cited by
- 35
- References
- 8
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coculture with hiPS-derived intestinal cells enhanced human hepatocyte functions in a pneumatic-pressure-driven two-organ microphysiological system. https://app.cochat.ai/papers/10.1038/s41598-021-84861-y
- The paper
- Shinohara, M., Arakawa, H., Oda, Y., Shiraki, N., Sugiura, S., Nishiuchi, T., Satoh, T., Iino, K., Leo, S., Kato, Y., Araya, K., Kawanishi, T., Nakatsuji, T., Mitsuta, M., Inamura, K., Goto, T., Shinha, K., Nihei, W., Komori, K., . . . Kimura, H. (2021). Coculture with hiPS-derived intestinal cells enhanced human hepatocyte functions in a pneumatic-pressure-driven two-organ microphysiological system. Scientific Reports. https://doi.org/10.1038/s41598-021-84861-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.