Cited by 35

A Kinetic Pump Integrated Microfluidic Plate (KIM-Plate) with High Usability for Cell Culture-Based Multiorgan Microphysiological Systems

Shinha, Kenta, Nihei, Wataru, Nakamura, Hiroko, Goto, Tomomi, Kawanishi, Takumi, Ishida, Naoki, Yamazaki, Nao, Imakura, Yuki +7 more·2021·Micromachines

Abstract

Microphysiological systems (MPSs), including organ-on-a-chip (OoC), have attracted attention as a novel method for estimating the effects and side effects of drugs in drug discovery. To reproduce the dynamic in vivo environment, previous MPSs were connected to pump systems to perfuse culture medium. Therefore, most MPSs are not user-friendly and have poor throughput. We aimed to develop a kinetic pump integrated microfluidic plate (KIM-Plate) by applying the stirrer-based micropump to an open access culture plate to improve the usability of MPSs. The KIM-Plate integrates six multiorgan MPS (MO-MPS) units and meets the ANSI/SBS microplate standards. We evaluated the perfusion function of the kinetic pump and found that the KIM-Plate had sufficient agitation effect. Coculture experiments with PXB cells and hiPS intestinal cells showed that the TEER of hiPS intestinal cells and gene expression levels related to the metabolism of PXB cells were increased. Hence, the KIM-Plate is an innovative tool for the easy coculture of highly conditioned cells that is expected to facilitate cell-based assays in the fields of drug discovery and biology because of its usability and high throughput nature.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/mi12091007

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In cell-culture insert systems, cellular uptake and transport across the cell barrier can be studied with the porous membrane.

    “For the cell-culture insert system, cellular uptake and transport across the cell barrier (e.g., endothelial cells and intestinal epithelial cells) can be studied with the porous membrane;”

    From Gut-liver-axis microphysiological system for studying cellular fluidic shear stress and inter-tissue interaction (2022) · cites this paper as [11]

    Methods §2.6 describes using culture inserts to measure apical-to-basolateral transport in intestinal cells, and Results §3.2 calculates permeability using the membrane surface area. The paper does not show a cellular uptake assay or an endothelial-cell barrier experiment, so those examples extend beyond what it demonstrates. Page numbers are unavailable in our copy. (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • Reported GLA-MPSs showed better predictive capabilities of organ-to-organ interaction compared to normal static cell-culture models.

    “They showed better predictive capabilities of organ to organ interaction, compared to normal static cell-culture models.”

    From Gut-liver-axis microphysiological system for studying cellular fluidic shear stress and inter-tissue interaction (2022) · cites this paper as [11]

    The Introduction says multiorgan MPSs can evaluate interorgan interactions in real time and may improve pharmacokinetic predictions. But the paper studies a KIM-Plate, not a system it calls a GLA-MPS, and does not show better predictive capability than static cell-culture models; its static-culture comparison in Results and Discussion §3.1 concerns cell number and morphology. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • Current GLA-MPSs are based on two approaches: the cell-culture insert in microtiter plates and microfluidic devices.

    “The current GLA-MPSs are based on two approaches: the cell-culture insert in the microtiter plates 7,11 and microfluidic devices.12,13”
  • A number of MPSs as an in vitro GLA model (GLA-MPS) have been reported, such as GLA for metabolism and inflammation axes.

    “Thus far, a number of MPSs as an in vitro GLA model (GLA-MPS) have been reported, such as GLA for metabolism and inflammation axess.3,7- 11”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 37

  1. [1]Kimura H. Sakai Y. Fujii T. Organ/body-on-a-chip based on microfluidic technology for drug discovery Drug Metab. Pharmacokinet. 2018 33 43 48 10.1016/j.dmpk.2017.11.003 29175062 · DOI · Paper page
  2. [2]Ishida S. Organs-on-a-chip: Current applications and consideration points for in vitro ADME-Tox studies Drug Metab. Pharmacokinet. 2018 33 49 54 10.1016/j.dmpk.2018.01.003 29398302 · DOI
  3. [3]Franzen N. van Harten W.H. Retèl V.P. Loskill P. van den Eijnden-van Raaij J. IJzerman M. Impact of organ-on-a-chip technology on pharmaceutical R&D costs Drug Discov. Today 2019 24 1720 1724 10.1016/j.drudis.2019.06.003 31185290 · DOI
  4. [4]Fowler S. Chen W.L.K. Duignan D.B. Gupta A. Hariparsad N. Kenny J.R. Lai W.G. Liras J. Phillips J.A. Gan J. Microphysiological systems for ADME-related applications: Current status and recommendations for system development and characterization Lab. Chip. 2020 20 446 467 10.1039/C9LC00857H 31932816 · DOI · Paper page
  5. [5]Huh D. Matthews B.D. Mammoto A. Montoya-Zavala M. Hsin H.Y. Ingber D.E. Reconstituting Organ-Level Lung Functions on a Chip Science 2010 328 1662 1668 10.1126/science.1188302 20576885 PMC8335790 · DOI · Paper page
  6. [6]Jang B.K. Mehr A.P. Geraldine A. Mcpartlin L.A. Chungc S. Suhd K. Ingber D.E. Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment Integr. Biol. 2013 5 1119 1129 10.1039/c3ib40049b 23644926 · DOI
  7. [7]Vriend J. Peters J.G.P. Nieskens T.T.G. Škovroňová R. Blaimschein N. Schmidts M. Roepman R. Schirris T.J.J. Russel F.G.M. Masereeuw R. Flow stimulates drug transport in a human kidney proximal tubule-on-a-chip independent of primary cilia Biochim. Biophys. Acta-Gen. Subj. 2020 1864 1 12 10.1016/j.bbagen.2019.129433 31520681 · DOI
  8. [8]Zhou M. Zhang X. Wen X. Wu T. Wang W. Yang M. Wang J. Fang M. Lin B. Lin H. Development of a Functional Glomerulus at the Organ Level on a Chip to Mimic Hypertensive Nephropathy Sci. Rep. 2016 6 1 13 10.1038/srep31771 27558173 PMC4997336 · DOI
  9. [9]Matsumoto S. Safitri A.R. Danoy M. Maekawa T. Kinoshita H. Shinohara M. Sakai Y. Fujii T. Leclerc E. Investigation of the hepatic respiration and liver zonation on rat hepatocytes using an integrated oxygen biosensor in a microscale device Biotechnol. Prog. 2019 35 1 13 10.1002/btpr.2854 31131557 · DOI
  10. [10]Nakao Y. Kimura H. Sakai Y. Fujii T. Bile canaliculi formation by aligning rat primary hepatocytes in a microfluidic device Biomicrofluidics 2011 5 1 7 10.1063/1.3580753 PMC3145237 21799718 · DOI
  11. [11]Leonard A. Bertero A. Powers J.D. Beussman K.M. Bhandari S. Regnier M. Murry C.E. Sniadecki N.J. Afterload promotes maturation of human induced pluripotent stem cell derived cardiomyocytes in engineered heart tissues J. Mol. Cell. Cardiol. 2018 118 147 158 10.1016/j.yjmcc.2018.03.016 29604261 PMC5940558 · DOI
  12. [12]Lee S. Sung J. Microtechnology-Based Multi-Organ Models Bioengineering 2017 4 46 10.3390/bioengineering4020046 28952525 PMC5590483 · DOI
  13. [13]van Berlo D. van de Steeg E. Amirabadi H.E. Masereeuw R. The potential of multi-organ-on-chip models for assessment of drug disposition as alternative to animal testing Curr. Opin. Toxicol. 2021 27 8 17 10.1016/j.cotox.2021.05.001 · DOI
  14. [14]Ronaldson-Bouchard K. Vunjak-Novakovic G. Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development Cell Stem Cell 2018 22 310 324 10.1016/j.stem.2018.02.011 29499151 PMC5837068 · DOI · Paper page
  15. [15]Arakawa H. Sugiura S. Kawanishi T. Shin K. Toyoda H. Satoh T. Sakai Y. Kanamori T. Kato Y. Kinetic analysis of sequential metabolism of triazolam and its extrapolation to humans using an entero-hepatic two-organ microphysiological system Lab. Chip 2020 20 537 547 10.1039/C9LC00884E 31930237 · DOI · Paper page
  16. [16]Miller P.G. Shuler M.L. Design and demonstration of a pumpless 14 compartment microphysiological system Biotechnol. Bioeng. 2016 113 2213 2227 10.1002/bit.25989 27070809 · DOI
  17. [17]Sung J.H. Kam C. Shuler M.L. A microfluidic device for a pharmacokinetic-pharmacodynamic (PK-PD) model on a chip Lab. Chip. 2010 10 446 455 10.1039/b917763a 20126684 · DOI
  18. [18]Lee H. Kim D.S. Ha S.K. Choi I. Lee J.M. Sung J.H. A pumpless multi-organ-on-a-chip (MOC) combined with a pharmacokinetic-pharmacodynamic (PK-PD) model Biotechnol. Bioeng. 2017 114 432 443 10.1002/bit.26087 27570096 · DOI
  19. [19]Marx U. Akabane T. Andersson T.B. Baker E. Beilmann M. Beken S. Brendler-Schwaab S. Cirit M. David R. Dehne E.M. Biology-inspired microphysiological systems to advance patient benefit and animal welfare in drug development Altex 2020 37 364 394 10.14573/altex.2001241 PMC7863570 32113184 · DOI
  20. [20]Mastrangeli M. Millet S. van den Eijnden-Van Raaij J. Organ-on-chip in development: Towards a roadmap for organs-on-chip Altex 2019 36 650 668 10.14573/altex.1908271 31664458 · DOI
  21. [21]Theobald J. Ghanem A. Wallisch P. Banaeiyan A.A. Andrade-Navarro M.A. Taškova K. Haltmeier M. Kurtz A. Becker H. Reuter S. Liver-Kidney-on-Chip to Study Toxicity of Drug Metabolites ACS Biomater. Sci. Eng. 2018 4 78 89 10.1021/acsbiomaterials.7b00417 33418680 · DOI
  22. [23]Liu D. Jiao S. Wei J. Zhang X. Pei Y. Pei Z. Li J. Du Y. Investigation of absorption, metabolism and toxicity of ginsenosides compound K based on human organ chips Int. J. Pharm. 2020 587 119669 10.1016/j.ijpharm.2020.119669 32702454 · DOI
  23. [24]Chramiec A. Teles D. Yeager K. Marturano-Kruik A. Pak J. Chen T. Hao L. Wang M. Lock R. Tavakol D.N. Integrated human organ-on-a-chip model for predictive studies of anti-tumor drug efficacy and cardiac safety Lab. Chip. 2020 20 4357 4372 10.1039/D0LC00424C 32955072 PMC8092329 · DOI
  24. [27]Satoh T. Narazaki G. Sugita R. Kobayashi H. Sugiura S. Kanamori T. A pneumatic pressure-driven multi-throughput microfluidic circulation culture system Lab. Chip. 2016 16 2339 2348 10.1039/C6LC00361C 27229626 · DOI
  25. [28]Satoh T. Sugiura S. Shinji K. Nagasaki R. Ishida S. Kikuchi K. Kakiki M. Kanamori T. A multi-throughput multi-organ-on-a-chip system on a plate formatted pneumatic pressure-driven medium circulation platform Lab. Chip. 2018 18 115 125 10.1039/C7LC00952F 29184959 · DOI · Paper page
  26. [29]Lee D.W. Ha S.K. Choi I. Sung J.H. 3D gut-liver chip with a PK model for prediction of first-pass metabolism Biomed. Microdevices 2017 19 1 13 10.1007/s10544-017-0242-8 29116458 · DOI
  27. [30]Lee D.W. Lee S.H. Choi N. Sung J.H. Construction of pancreas-muscle-liver microphysiological system (MPS) for reproducing glucose metabolism Biotechnol. Bioeng. 2019 116 1 13 10.1002/bit.27151 31429925 · DOI
  28. [31]McAleer C.W. Long C.J. Elbrecht D. Sasserath T. Bridges L.R. Rumsey J.W. Martin C. Schnepper M. Wang Y. Schuler F. Multi-organ system for the evaluation of efficacy and off-target toxicity of anticancer therapeutics Sci. Transl. Med. 2019 11 1 12 10.1126/scitranslmed.aav1386 31217335 · DOI · Paper page
  29. [32]Wang Y.I. Shuler M.L. UniChip enables long-term recirculating unidirectional perfusion with gravity-driven flow for microphysiological systems Lab. Chip. 2018 18 2563 2574 10.1039/C8LC00394G 30046784 PMC6143176 · DOI
  30. [33]Kimura H. Yamamoto T. Sakai H. Sakai Y. Fujii T. An integrated microfluidic system for long-term perfusion culture and on-line monitoring of intestinal tissue models Lab. Chip. 2008 8 741 746 10.1039/b717091b 18432344 · DOI
  31. [34]Nakayama H. Kimura H. Fujii T. Sakai Y. Image-based evaluations of distribution and cytotoxicity of Irinotecan (CPT-11) in a multi-compartment micro-cell coculture device J. Biosci. Bioeng. 2014 117 756 762 10.1016/j.jbiosc.2013.11.019 24374121 · DOI
  32. [35]Kimura H. Ikeda T. Nakayama H. Sakai Y. Fujii T. An On-Chip Small Intestine-Liver Model for Pharmacokinetic Studies J. Lab. Autom. 2015 20 265 273 10.1177/2211068214557812 25385717 · DOI · Paper page
  33. [36]Shinha K. Nihei W. Ono T. Nakazato R. Kimura H. A pharmacokinetic-pharmacodynamic model based on multi-organ-on-a-chip for drug-drug interaction studies Biomicrofluidics 2020 14 1 9 10.1063/5.0011545 PMC8719524 34992705 · DOI
  34. [37]Kabeya T. Mima S. Imakura Y. Miyashita T. Ogura I. Yamada T. Yasujima T. Yuasa H. Iwao T. Matsunaga T. Pharmacokinetic functions of human induced pluripotent stem cell-derived small intestinal epithelial cells Drug Metab. Pharmacokinet. 2020 35 374 382 10.1016/j.dmpk.2020.04.334 32651148 · DOI
  35. [38]Zeller P. Legendre A. Jacques S. Fleury M.J. Gilard F. Tcherkez G. Leclerc E. Hepatocytes cocultured with Sertoli cells in bioreactor favors Sertoli barrier tightness in rat J. Appl. Toxicol. 2017 37 287 295 10.1002/jat.3360 27440042 · DOI
  36. [39]Shinohara M. Arakawa H. Oda Y. Shiraki N. Sugiura S. Nishiuchi T. Satoh T. Iino K. Leo S. Kato Y. Coculture with hiPS-derived intestinal cells enhanced human hepatocyte functions in a pneumatic-pressure-driven two-organ microphysiological system Sci. Rep. 2021 11 1 10 10.1038/s41598-021-84861-y 33686099 PMC7940409 · DOI
  37. [40]Klaassen T. Jetter A. Tomalik-Scharte D. Kasel D. Kirchheiner J. Jaehde U. Fuhr U. Assessment of urinary mephenytoin metrics to phenotype for CYP2C19 and CYP2B6 activity Eur. J. Clin. Pharmacol. 2008 64 387 398 10.1007/s00228-007-0416-z 18071681 · DOI

Cited by

Sorted by citations

Authors
Shinha, K., Nihei, W., Nakamura, H., Goto, T., Kawanishi, T., Ishida, N., Yamazaki, N., Imakura, Y., Mima, S., Inamura, K., Arakawa, H., Nishikawa, M., Kato, Y., Sakai, Y., & Kimura, H.
Affiliations
  • Department of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan
  • Faculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa 920-1192, Japan
  • Bio Science & Engineering Laboratory, FUJIFILM Corporation, 577 Ushijima, Kaisei-machi 258-8577, Japan
  • Department of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Tokyo 113-8654, Japan
Venue
Micromachines
Publisher
MDPI AG
Published
2021-08-24
Volume
12
Issue
9
Pages
1007
ISSN
2072-666X
Cited by
35
References
3
Language
en
Funders
  • Japan Agency for Medical Research and Development (17be0304201h0001)
  • Japan Society for the Promotion of Science (18H01849)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review