Millimetre-scale magnetocardiography of living rats with thoracotomy
Open accessThe DOI matches its Crossref record; 67 of the 68 references it cites were found in a registry or an index.
Abstract
Abstract Magnetocardiography is a contactless imaging modality for electric current propagation in the cardiovascular system. Although conventional sensors provide sufficiently high sensitivity, their spatial resolution is limited to a centimetre-scale, which is inadequate for revealing the intra-cardiac electrodynamics such as rotational waves associated with ventricular arrhythmias. Here, we demonstrate invasive magnetocardiography of living rats at a millimetre-scale using a quantum sensor based on nitrogen-vacancy centres in diamond. The acquired magnetic images indicate that the cardiac signal source is well explained by vertically distributed current dipoles, pointing from the right atrium base via the Purkinje fibre bundle to the left ventricular apex. We also find that this observation is consistent with and complementary to an alternative picture of electric current density distribution calculated with a stream function method. Our technique will enable the study of the origin and progression of various cardiac arrhythmias, including flutter, fibrillation, and tachycardia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Magnetocardiography based on a solid-state quantum sensor. a Schematic of the rat magnetocardiography (MCG) setup. A living rat ' s heart remains approximately one millimetre below a diamond chip containing an ensemble of nitrogen-vacancy (NV) centres. The rat is scanned automatically along the XYaxes for magnetic field mapping and manually along the Z-axis for height adjustment. An electrocardiography (ECG) signal is monitored through ECG profilers concurrently with the MCG. The NV centres are excited by a 2.0 W green laser light. This excitation entails spin-state-dependent fluorescence collected by an aspheric condenser lens. b NVcentre energy level diagram. The mS = ±1 ground states are split by a bias magnetic field and mixed by microwaves resonant with the NV transition frequencies. Each of the ground states are further split by hyperfine interactions with the host 14 N nuclear spin. c Enlarged view of the heart and diamond. Electric currents flowing through the heart generate a circulating field (blue arrows). The NV centres (red arrows) along the [111] orientation are sensitive to the Z-component of the magnetic field. d Magnetometry principle. The time-varying cardiac magnetic field (blue), which shifts the NV transition frequency, is converted to a change in the lock-in-demodulated fluorescence signal (red). Five peaks are observed in the lock-in optically detected magnetic resonance (ODMR) spectrum because three hyperfine transition frequencies are excited with three-tone microwaves. e Magnetic field sensitivity across the rat ' s heart signal frequency band of DC ~200 Hz. The black dashed line indicates 140 pT Hz -1/2 .](https://figures.cochat.ai/paper-figures/e2080dab110a42918fe784cbd9e371c2/millimetre-scale-magnetocardiography-of-living-rats-with-thoracotomy-figure-1.png)



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Since the best reported diamond magnetometers’ sensitivity is between 12 and 50 pT/Hz1/2, they are suitable for experimental recording of magnetic fields from isolated nerve or muscle neuronal action potentials isolated nerve or muscle tissues (294) or even for invasive, close-proximity, high-resolution MCG of living rats (208), but do not have sufficient sensitivity to compete with SQUIDs or OPMs”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [208]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“In fact, when the ECG and cardiac enzyme patterns cannot yet be diagnostic, the higher sensitivity of MCG in detecting myocardial ischemia at an early stage is only one of the advantages arising by the more comprehensive biomagnetic electrophysiological assessment, which has the potential to non-invasively detect electrogenic phenomena at cellular and even subcellular levels (86, 208).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [208]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vos, T., Lim, S. S., Abbafati, C., Abbas, K. M., Abbasi, M., Abbasifard, M., Abbasi-Kangevari, M., Abbastabar, H., Abd-Allah, F., Abdelalim, A., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30925-9 · Cited by 19,358
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
The surgical treatment of atrial fibrillation
Cox, J. L., Schuessler, R. B., D’Agostino, H. J., Stone, C. M., Chang, B.-C., Cain, M. E., Corr, P. B., & Boineau, J. P. (1991) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)36684-x · Cited by 1,464
Spatial and temporal organization during cardiac fibrillation
Gray, R. A., Pertsov, A. M., & Jalife, J. (1998) · Nature · doi:10.1038/32164 · Cited by 958
Artificial intelligence-enhanced electrocardiography in cardiovascular disease management
Siontis, K. C., Noseworthy, P. A., Attia, Z. I., & Friedman, P. A. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00503-2 · Cited by 914
Gepstein, L., Hayam, G., & Ben-Haim, S. A. (1997) · Circulation · doi:10.1161/01.cir.95.6.1611 · Cited by 759
Temperature Dependence of the Nitrogen-Vacancy Magnetic Resonance in Diamond
Acosta, V. M., Bauch, E., Ledbetter, M. P., Waxman, A., Bouchard, L.-S., & Budker, D. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070801 · Cited by 735
Optical magnetic imaging of living cells
Le Sage, D., Arai, K., Glenn, D. R., DeVience, S. J., Pham, L. M., Rahn-Lee, L., Lukin, M. D., Yacoby, A., Komeili, A., & Walsworth, R. L. (2013) · Nature · doi:10.1038/nature12072 · Cited by 730
Self-citation
Cited by
Sensitive ac and dc magnetometry with nitrogen-vacancy-center ensembles in diamond
Barry, J. F., Steinecker, M., Alsid, S. T., Majumder, J. A., Pham, L., O’Keeffe, M. F., & Braje, D. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.044069 · Cited by 140
Diamond Integrated Quantum Nanophotonics: Spins, Photons and Phonons
Shandilya, P. K., Flågan, S., Carvalho, N. C., Zohari, E., Kavatamane, V. K., Losby, J. E., & Barclay, P. E. (2022) · Journal of Lightwave Technology · doi:10.1109/jlt.2022.3210466 · Cited by 99
“NV based sensors are beginning to be employed in biomedical imaging [330], [337], [340] but”
BackgroundClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Recent progress in hybrid diamond photonics for quantum information processing and sensing
Katsumi, R., Takada, K., Jelezko, F., & Yatsui, T. (2025) · Communications Engineering · doi:10.1038/s44172-025-00398-2 · Cited by 96
“---------------------------------------------------------------------- Reviewer #1”
Fiber-Coupled Diamond Magnetometry with an Unshielded Sensitivity of 30 pT / Hz
Graham, S. M., Rahman, A., Munn, L., Patel, R. L., Newman, A. J., Stephen, C. J., Colston, G., Nikitin, A. P., Edmonds, A. M., Twitchen, D. J., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.044042 · Cited by 71
“High-sensitivity NVC magnetometers with portable fiber-coupled sensor heads are more suitable than purely table-top setups for a wide range of applications, from magnetocardiography (MCG) [33, 47] to the detection of corrosion in steel [13, 15].”
BackgroundInfluentialKurashima, K., Kataoka, M., Nakano, T., Fujiwara, K., Kato, S., Nakamura, T., Yuzawa, M., Masuda, M., Ichimura, K., Okatake, S., et al. (2023) · Sensors · doi:10.3390/s23020646 · Cited by 56
Brala, D., Thevathasan, T., Grahl, S., Barrow, S., Violano, M., Bergs, H., Golpour, A., Suwalski, P., Poller, W., Skurk, C., et al. (2023) · Journal of the American Heart Association · doi:10.1161/jaha.122.027619 · Cited by 54
“16 Magnetocardiography has the capability to detect the magnetic field of the heart at a high level of precision (10 −15 to 10 −11 T).”
Sekiguchi, N., Fushimi, M., Yoshimura, A., Shinei, C., Miyakawa, M., Taniguchi, T., Teraji, T., Abe, H., Onoda, S., Ohshima, T., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.064010 · Cited by 61
Self-citationLiu, Q., Xie, F., Peng, X., Hu, Y., Wang, N., Zhang, Y., Wang, Y., Li, L., Chen, H., Cheng, J., et al. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202300210 · Cited by 38
Nitrogen related paramagnetic defects: Decoherence source of ensemble of NV− center
Shinei, C., MASUYAMA, Y., Miyakawa, M., Abe, H., Ishii, S., Saiki, S., Onoda, S., Taniguchi, T., Ohshima, T., & Teraji, T. (2022) · Journal of Applied Physics · doi:10.1063/5.0103332 · Cited by 37
Self-citationWang, C., Liu, Q., Hu, Y., Xie, F., Krishna, K., Wang, N., Wang, L., Wang, Y., Toussaint, K. C., Cheng, J., et al. (2023) · Review of Scientific Instruments · doi:10.1063/5.0089908 · Cited by 34
Nitrogen-related point defects in homoepitaxial diamond (001) freestanding single crystals
Teraji, T., & Shinei, C. (2023) · Journal of Applied Physics · doi:10.1063/5.0143652 · Cited by 26
Self-citationHansen, N. W., Webb, J. L., Troise, L., Olsson, C., Tomasevic, L., Brinza, O., Achard, J., Staacke, R., Kieschnick, M., Meijer, J., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-39539-y · Cited by 35
“We highlight that the measurements we present in this work are substantially more challenging than previous work on much more biologically robust living systems such as marine invertebrates 32 or cardiac tissue in living whole-animal study 33 .”
Noninvasive magnetocardiography of a living rat based on a diamond quantum sensor
Yu, Z., Xie, Y., Jin, G., Zhu, Y., Zhang, Q., Shi, F., Wan, F.-Y., Luo, H., Tang, A., & Rong, X. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.064028 · Cited by 29
Fujiwara, M., Inoue, S., Masuno, S., Fu, H., Tokita, S., Hashida, M., & Mizuochi, N. (2023) · APL Photonics · doi:10.1063/5.0137093 · Cited by 19
An Integrated Magnetometer Module With MFCs Based on Diamond NV Centers
Mao, X., Huang, K., Ran, G., Huang, Q., Qu, S., He, X., Hu, Q., & Lin, Z. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3284520 · Cited by 20
“tum sensing [2], microbial probes [3], quantum computing [4],”
BackgroundHigh dynamic-range and portable magnetometer using ensemble nitrogen-vacancy centers in diamond
Kumar, H., Shishir, D., Mangat, M., Tallur, S. G., & Saha, K. (2024) · Review of Scientific Instruments · doi:10.1063/5.0205105 · Cited by 29
“Similarly, high sensitivities achievable with NV – of up to 1 pT 5,6 has made it possible to detect very weak magnetic fields emanating from very small currents in biological samples 7–9 .”
BackgroundHigh-sensitivity nanoscale quantum sensors based on a diamond micro-resonator
Katsumi, R., Takada, K., Kawai, K., Sato, D., & Yatsui, T. (2025) · Communications Materials · doi:10.1038/s43246-025-00770-x · Cited by 29
“Moreover, magnetic fi eld sensitivities of the order of picoteslas have been achieved by employing an ensemble of NV centers (with a typical density of (cid:2) 10 17 cm − ) 9 ; these are bene fi cial for medical applications requiring the detection of weak magnetic fi elds from the brain and heart 10 .”
High frequency magnetometry with an ensemble of spin qubits in hexagonal boron nitride
Patrickson, C. J., Baber, S., Gaál, B. B., Ramsay, A. J., & Luxmoore, I. J. (2024) · npj Quantum Information · doi:10.1038/s41534-023-00796-4 · Cited by 16
Quantum diamond microscope for dynamic imaging of magnetic fields
Tang, J., Yin, Z., Hart, C., Blanchard, J. W., Oon, J. T., Bhalerao, S., Schloss, J. M., Turner, M. J., & Walsworth, R. L. (2023) · AVS Quantum Science · doi:10.1116/5.0176317 · Cited by 21
Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond
Basso, L., Kehayias, P., Henshaw, J., Joshi, G., Lilly, M. P., Jordan, M. B., & Mounce, A. M. (2025) · Journal of Applied Physics · doi:10.1063/5.0253730 · Cited by 20
“…materials 18,19 , to observe fer-a) Electronic mail: lbasso@sandia.gov b) Electronic mail: ammounce@sandia.gov romagnetic domains for magnetic memory 20 and hardware security 21 applications, for characterization of integrated circuits 22,23 , as well as to characterize biological samples 24,25 .”
BackgroundCompact and portable quantum sensor module using diamond NV centers
Deguchi, H., Hayashi, T., Saito, H., Nishibayashi, Y., Teramoto, M., Fujiwara, M., Morishita, H., Mizuochi, N., & Tatsumi, N. (2023) · Applied Physics Express · doi:10.35848/1882-0786/acd836 · Cited by 14
Charge stabilization of shallow nitrogen-vacancy centers using graphene/diamond junctions
Haruyama, M., Okigawa, Y., Okada, M., Nakajima, H., Okazaki, T., Kato, H., Makino, T., & Yamada, T. (2023) · Applied Physics Letters · doi:10.1063/5.0143062 · Cited by 13
Ferrimagnetic Oscillator Magnetometer
Barry, J. F., Irion, R. A., Steinecker, M., Freeman, D. K., Kedziora, J., Wilcox, R. G., & Braje, D. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.044044 · Cited by 17
Tsuji, T., Sekiguchi, T., Iwasaki, T., & Hatano, M. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202300194 · Cited by 14
Self-citationFast Scanning Nitrogen-Vacancy Magnetometry by Spectrum Demodulation
Welter, P., Josteinsson, B., Josephy, S., Wittmann, A., Morales, A., Puebla‐Hellmann, G., & Degen, C. L. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.034003 · Cited by 12
Interaxial time-domain interference in single-beam SERF magnetometer
Lin, S., Yuan, Z., Tang, J., Lu, J., Cao, Q., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.112890 · Cited by 11
Electroluminescence of negatively charged single NV centers in diamond
Haruyama, M., Kato, H., Ogura, M., Kato, Y., Takeuchi, D., Yamasaki, S., Iwasaki, T., Morishita, H., Fujiwara, M., Mizuochi, N., et al. (2023) · Applied Physics Letters · doi:10.1063/5.0138050 · Cited by 11
Self-citationAbrahams, G., Ellul, E., Robertson, I. O., Khalid, A., Greentree, A. D., Gibson, B. C., & Tetienne, J. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.054076 · Cited by 15
Katsumi, R., Takada, K., Naruse, S., Kawai, K., Sato, D., Hizawa, T., & Yatsui, T. (2023) · Applied Physics Letters · doi:10.1063/5.0161268 · Cited by 13
Compact and Stable Diamond Quantum Sensors for Wide Applications
Kainuma, Y., Hatano, Y., Shibata, T., Sekiguchi, N., Nakazono, A., Kato, H., Onoda, S., Ohshima, T., Hatano, M., & Iwasaki, T. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202300456 · Cited by 16
Self-citationLi, Y., Zheng, D., Liu, Z., Wang, H., Liu, Y., Hou, C., Guo, H., Li, Z., Sugawara, Y., Tang, J., et al. (2023) · Micromachines · doi:10.3390/mi14101823 · Cited by 11
Atom-based quantum sensing of electromagnetic fields
Kitching, J. E., Shaffer, J. P., & Budker, D. (2025) · Optica · doi:10.1364/optica.569334 · Cited by 19
Quantum for biology: Spectroscopy and sensing
Ghamsari, M. S., & Baniasadi, F. (2024) · Innovation and Emerging Technologies · doi:10.1142/s2737599424300058 · Cited by 13
Tsuji, T., Shinei, C., Iwasaki, T., Hatano, M., & Teraji, T. (2024) · Applied Physics Express · doi:10.35848/1882-0786/ad88d4 · Cited by 8
Self-citationOhkubo, M. (2023) · Review of Scientific Instruments · doi:10.1063/5.0167372 · Cited by 9
Tolstrup, K., Akhtari, M., Brisinda, D., Meloni, A. M., Siegel, R. J., & Fenici, R. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100483 · Cited by 12
Shinei, C., MASUYAMA, Y., Abe, H., Miyakawa, M., Taniguchi, T., Ohshima, T., & Teraji, T. (2025) · Communications Materials · doi:10.1038/s43246-025-00782-7 · Cited by 7
Self-citationWu, H., Zhang, H., Cui, P., Zhao, X., & Zheng, S. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116306 · Cited by 6
Tsuji, T., Iwasaki, T., & Hatano, M. (2023) · Applied Physics Express · doi:10.35848/1882-0786/acb7c7 · Cited by 6
Self-citationBayesian-Based Hybrid Method for Rapid Optimization of NV Center Sensors
Tian, J., Said, R. S., Jelezko, F., Cai, J., & Xiao, L. (2023) · Sensors · doi:10.3390/s23063244 · Cited by 9
Performance evaluation of a diamond quantum magnetometer for biomagnetic sensing: A phantom study
Sekiguchi, N., Kainuma, Y., Fushimi, M., Shinei, C., Miyakawa, M., Taniguchi, T., Teraji, T., Abe, H., Onoda, S., Ohshima, T., et al. (2025) · Applied Physics Letters · doi:10.1063/5.0254828 · Cited by 7
Self-citationObservation and Control of π-Pulse Resonance in SERF Magnetometer
Lin, S., Tang, J., Yuan, Z., Li, C., & Zhai, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3341112 · Cited by 5
“Among them, the precision measurement of weak magnetic fields using atomic magnetometers (AMs) is widely used from frontier science to practical applications [6], [7], [8], [9], [10], [11], [12].”
BackgroundAlbertová, P., Gram, M., Blaimer, M., Bauer, W. R., Jakob, P. M., & Nordbeck, P. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30190 · Cited by 6
Cross‐Correlated Quantum Thermometry Using Diamond Containing Dual‐Defect Centers
Gupta, M., Zhang, T., Yeung, L., Zhang, J., Tan, Y., Yiu, Y. C., Zhang, S., Wang, Q., Wang, Z., & Chu, Z. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300103 · Cited by 5
Transverse magnetic field effects on diamond quantum sensor for EV battery monitor
Hatano, Y., Tanigawa, J., Nakazono, A., Sekiguchi, T., Kainuma, Y., Abe, H., Onoda, S., Ohshima, T., Iwasaki, T., & Hatano, M. (2024) · Frontiers in Quantum Science and Technology · doi:10.3389/frqst.2024.1432096 · Cited by 4
Self-citationZadeh‐Haghighi, H., Golami, O., Kavatamane, V. K., Barclay, P. E., & Simon, C. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.064015 · Cited by 5
Zhang, H., Li, Z., Ma, Z., Guo, H., Wen, H. F., Li, X., Tang, J., & Liu, J. (2025) · Photonics Research · doi:10.1364/prj.553460 · Cited by 4
Low frequency signal detection via correlated Ramsey measurements
Oviedo-Casado, S., Prior, J., & Cerrillo, J. (2024) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2024.107691 · Cited by 6
“The low frequency regime features prominently in a wide variety of fields, ranging from the study of J couplings in molecules, to the life sciences [34, 54–56].”
BackgroundZhang, Q., Wang, H., Wang, G., Zheng, D., Hou, C., Fu, J., Qin, L., Wen, H. F., Li, Z., Li, X., et al. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3561502 · Cited by 3
“It is widely used in magnetic field detection [5], [6], [7], [8] battery current testing [9], [10], biomedicine [11], and basic physics research [12], [13].”
Synthesis strategies of magnetic inorganic nanomaterials to biomedical and spintronic applications
Thắng, N. H. (2026) · Chemical Papers · doi:10.1007/s11696-026-04706-8 · Cited by 6
“Arai et al. (2022) applied a signal space separation (SSS) method to MTJ sensor arrays, achieving environmental noise reduction of up to -73 dB at 7 Hz.”
Quantum diamond microscopy with optimized magnetic field sensitivity and sub-ms temporal resolution
Oh, S., Lee, S.-J., Shim, J. H., Song, N. W., & Hiên, T. T. (2023) · Journal of Applied Physics · doi:10.1063/5.0142448 · Cited by 3
Hu, Q., Huang, K., Mao, X., Ran, G., He, X., Lin, Z., Hu, T., & Ran, S. (2024) · Diamond and Related Materials · doi:10.1016/j.diamond.2024.111858 · Cited by 3
Small Animal Biomagnetism Applications
Jensen, K., Bentzen, B. H., & Polzik, E. S. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_3 · Cited by 5
Fujisaki, I., Araki, Y., Hatano, Y., Sekiguchi, T., Kato, H., Onoda, S., Ohshima, T., Shibata, T., Iwasaki, T., & Hatano, M. (2023) · physica status solidi (a) · doi:10.1002/pssa.202300333 · Cited by 3
Self-citationMizuno, K., Fujisaki, I., Tomioka, H., Ishiwata, H., Onoda, S., Iwasaki, T., Arai, K., & Hatano, M. (2024) · Journal of Physics Communications · doi:10.1088/2399-6528/ad2b8b · Cited by 4
Self-citationMagnetic signature of thermoelectric cardiac dynamics
Crispino, A., Nicoletti, M., Loppini, A., Gizzi, A., Chiodo, L., Cherubini, C., & Filippi, S. (2025) · Physical review. E · doi:10.1103/physreve.111.l012401 · Cited by 5
Diamond-on-chip magnetic field camera for mobile imaging
Bopp, J. M., Conradi, H., Martinez, F. P. P., Palaci, A., Wollenberg, J., Flisgen, T., Liero, A., Christopher, H. C. P., Keil, N., Knolle, W., et al. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.034024 · Cited by 5
Wu, H., Zhao, X., Cui, P., Zhang, H., Liu, J., & Wen, T. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3533616 · Cited by 5
Compact and portable pulsed measurement module using diamond NV centers
Deguchi, H., Hayashi, T., Saito, H., Nishibayashi, Y., Teramoto, M., Fujiwara, M., Morishita, H., Mizuochi, N., & Tatsumi, N. (2025) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ade924 · Cited by 2
Yang, J., Zhang, J., Meng, X., Zheng, W., & Belhora, F. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c23656 · Cited by 2
Fenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100561 · Cited by 3
“Fortunately, experimental evidence already demonstrates that, with new sensor technologies, MCG can be recorded with millimeter-scale spatial accuracy [63].”
Fujisaki, I., Li, Z., Hatano, Y., Sekiguchi, T., Sekiguchi, N., Shinei, C., Miyakawa, M., Taniguchi, T., Teraji, T., Abe, H., et al. (2025) · Advanced Quantum Technologies · doi:10.1002/qute.202500056 · Cited by 2
Self-citationImpact of electric spatially discordant alternans on cardiac magnetic field
Nicoletti, M., Crispino, A., Loppini, A., Gizzi, A., Chiodo, L., Cherubini, C., & Filippi, S. (2025) · Physical review. E · doi:10.1103/ys62-2n7g · Cited by 4
Sensitivity improvement of a single-NV diamond magnetometer using a chiral waveguide
Takada, K., Katsumi, R., & Yatsui, T. (2023) · Optics Express · doi:10.1364/oe.509860 · Cited by 7
Emerging roles of NV-diamond magnetometry in brain mapping and bioimaging
Sharma, R., Chauhan, A. S., & Sharma, S. (2026) · Journal of Biological Physics · doi:10.1007/s10867-026-09703-2 · Cited by 2
“Notably, a recent study by Arai et al. that uses magnetocardiography in living rats presents one of the limited comparisons of this sort and shows that NV-diamond and OPM sensors can both detect heart magnetic signals under the same biological conditions [48].”
Wang, H., Wang, G., Miao, Q., Jia, Q., Yu, Y., Zheng, D., Wen, H. F., Li, Z., Guo, H., Li, Y., et al. (2026) · Optics & Laser Technology · doi:10.1016/j.optlastec.2026.115017 · Cited by 1
Magnetic field based investigation of Brugada syndrome
Nicoletti, M., Crispino, A., Loppini, A., Gizzi, A., Chiodo, L., Cherubini, C., & Filippi, S. (2026) · European Biophysics Journal · doi:10.1007/s00249-026-01826-7 · Cited by 1
“…signals at the cellular scale, offering new possibili - ties for high-precision electrophysiological assessments the molecular and biophysical mechanisms underlying arrhyth - mias in BrS and other channelopathies (Barry et al. 2016, 2020; Arai et al. 2022; Fenici et al. 2025; Yu et al. 2024).”
Effects of Magnetocardiography Array Errors on Cardiac Source Imaging
Zhang, M., Wang, Y., Li, P., Zhang, Y., Cui, Y., & Xiang, M. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3676206 · Cited by 2
Vector magnetometry using cavity-enhanced microwave readout in nitrogen-vacancy-center diamond
Wilcox, R. G., Phillips, D. F., Steinecker, M., Eisenach, E. R., Hawkins, C., Pham, L., Schloss, J. M., Englund, D. R., & Braje, D. (2026) · Physical Review Applied · doi:10.1103/wd4d-qf28 · Cited by 2
Magnetocardiography in the diagnosis of suspected ANOCA: a case series
Xue, X., Zhang, J. Y., Zhou, Y., Cheng, L., Zhu, Y., Liang, J., Tian, K., Xu, D., Xiang, S., Li, Q., et al. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1787320 · Cited by 1
“MCG can non-invasively detect electrogenic phenomena at the cellular and even subcellular levels (8, 9), making it an emerging novel method for detecting cardiac ischemia.”
Enhancing Current-Source Imaging in Magnetocardiography: The Impact of Sensor Array Configuration
Shang, W., Fushimi, M., Chikaki, S., & Sekino, M. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04343-y · Cited by 1
Self-citationExtremely low-frequency magnetic spectrum measurement method based on the NV center in diamond
Li, X., Wang, Q., Gao, W., Shi, Z., Guo, H., Luo, Z., Li, Z., Wen, H., Ma, Z., Tang, J., et al. (2023) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad034f
Sekino, M. (2023) · The Brain & Neural Networks · doi:10.3902/jnns.30.159
Self-citationCentra barwne azot-wakancja w diamencie – od klejnotów do technologii kwantowych
Mrózek, M., Wydział Fizyki, A. I. I. S. U., Wojciechowski, A. M., Gawlik, W., Wydział Fizyki, A. I. I. S. U., & Wydział Fizyki, A. I. I. S. U. (2023) · Postępy Fizyki · doi:10.61947/uw.pf.2023.74.1.2-13
Safi, B., Safi, F. R. M., & ATIF, A. (2023) · Nangarhar University international journal of biosciences. · doi:10.70436/nuijb.v2i03.65 · Cited by 1
The Principle and Application of Diamond Quantum Sensor
Hatano, Y., Nakazono, A., & Hatano, M. (2025) · The Journal of the Institute of Electrical Engineers of Japan · doi:10.1541/ieejjournal.145.318
Self-citationFenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2025) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd12090343 · Cited by 1
“This could be achieved by combining rVAPw reconstruction from MCG recorded with novel microfabricated millimeter-scale sensor arrays [61,62], high-resolution 3D magnetic source imaging [63], and integration with cardiac MRI [64].”
Recent advances in magnetocardiography
Kong, X., Yang, K., Zhang, Z., Pan, D., & Guo, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00001-2 · Cited by 2
Chakravarty, A., Ruhlmann, R., Halde, V., Roy-Guay, D., Pioro-Ladrière, M., Childress, L., & Bérubé-Lauzière, Y. (2026) · Journal of the Optical Society of America B · doi:10.1364/josab.583073
“Notably, at low Rabi frequency, where a single tone only addresses one hyperfine line, the contrast is diminished by approximately a factor of three; this corresponds to the regime where triple-tone driving is expected to enhance contrast [26].”
InfluentialMultichannel highly sensitive diamond quantum magnetometer
Yoshimura, A., Kanamoto, A., Sekiguchi, N., Shinei, C., Miyakawa, M., Taniguchi, T., Teraji, T., Abe, H., Onoda, S., Ohshima, T., et al. (2026) · Journal of Applied Physics · doi:10.1063/5.0303834 · Cited by 1
Self-citationAraki, Y., Sekiguchi, T., Hatano, Y., Sekiguchi, N., Shinei, C., Miyakawa, M., Taniguchi, T., Teraji, T., Abe, H., Onoda, S., et al. (2026) · Applied Physics Letters · doi:10.1063/5.0334709 · Cited by 3
Self-citationThuilot, T., Nietert, A., & Hennig, A. (2026) · tm - Technisches Messen · doi:10.1515/teme-2025-0116
“Initial studies, such as those by Patel [44] and Arai et al. [45], showed proof-of-concept results, with sensitivities in the nanotesla range and setups that required invasive procedures.”
Vector Field Enhancement With Magnetic Flux Concentrators for NV Diamond Magnetometry
Li, H., Radivojević, Z., Picheo, E., & Eggleston, M. S. (2026) · IEEE Sensors Letters · doi:10.1109/lsens.2026.3719841
“TheNVD – MFC system for vector magnetometry supports diverse applications, including aerospace applications navigation [21], anomaly detection [22], and medical imaging [23] with promising potential for miniaturization due to the relatively low laser and microwave power requirements [24].”
Human cardiac measurements with diamond magnetometers
Omar, M., Benke, M., Zhang, S., Zhang, J., Wang, Y., Kübler, M., Sharbati, P., Rahimpour, A., Gueck, A., Kapitonova, M., et al. (2026) · Science Advances · doi:10.1126/sciadv.aeg5281 · Cited by 8
“NV magnetometers have been demonstrated in animal studies for both invasive [17] and non-invasive MCG detection using flux concentrators [18].”
Xu, X., Zhang, X., Han, C., & Liu, Y. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3743998
“OPM-based magnetocardiography (MCG) systems enable noninvasive measurement of cardiac magnetic fields and electrophysiological activity [6], [7].”
Metadata
- Authors
- Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., Shinei, C., Miyakawa, M., Taniguchi, T., Yamazaki, M., Teraji, T., Ohshima, T., Hatano, M., Sekino, M., & Iwasaki, T.
- Affiliations
- Tokyo Institute of Technology (JP)
- Tohoku University (JP)
- The University of Tokyo (JP)
- National Institutes for Quantum Science and Technology (JP)
- National Institute for Materials Science (JP)
- Nagano Municipal Hospital (JP)
- Corresponding author
- Hatano, Mutsuko
- Sekino, Masaki
- Iwasaki, Takayuki
- ORCID
- Venue
- Communications Physics
- Published
- 2022-08-23
- Volume
- 5
- Issue
- 1
- Pages
- 200(1)-200(10)
- ISSN
- 2399-3650 (ISSN-L)
- OpenAlex
- W4292697381
- Cited by
- 85
- References
- 68
- Citations by year
- 2026: 15 · 2025: 19 · 2024: 15 · 2023: 33 · 2022: 3
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Communications Physics (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Institutional Repositories DataBase (IRDB) (submittedVersion)
- QST-Repository (National Institutes for Quantum and Radiological Science and Technology) (submittedVersion)
- Funders
- MEXT | JST | Precursory Research for Embryonic Science and Technology (JPMJPR20B1)
- Ministry of Education, Culture, Sports, Science and Technology (JPMXS0118068379, JPMXS0118067395)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- magnetocardiography, nitrogen-vacancy centers, diamond quantum sensors, current dipoles, ventricular arrhythmias, cardiac arrhythmias, thoracotomy, rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.