Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index; 13 of the 44 sources its claims cite were checked for support.
Abstract
Conventional preclinical models often miss drug toxicities, meaning the harm these drugs pose to humans is only realized in clinical trials or when they make it to market. This has caused the pharmaceutical industry to waste considerable time and resources developing drugs destined to fail. Organ-on-a-Chip technology has the potential improve success in drug development pipelines, as it can recapitulate organ-level pathophysiology and clinical responses; however, systematic and quantitative evaluations of Organ-Chips' predictive value have not yet been reported. 870 Liver-Chips were analyzed to determine their ability to predict drug-induced liver injury caused by small molecules identified as benchmarks by the Innovation and Quality consortium, who has published guidelines defining criteria for qualifying preclinical models. An economic analysis was also performed to measure the value Liver-Chips could offer if they were broadly adopted in supporting toxicity-related decisions as part of preclinical development workflows. Here, we show that the Liver-Chip met the qualification guidelines across a blinded set of 27 known hepatotoxic and non-toxic drugs with a sensitivity of 87% and a specificity of 100%. We also show that this level of performance could generate over $3 billion annually for the pharmaceutical industry through increased small-molecule R&D productivity. The results of this study show how incorporating predictive Organ-Chips into drug development workflows could…
Overview
CoChat Summary
## TL;DR
This study systematically evaluated a human Liver-Chip for drug-induced liver injury (DILI) prediction using 870 chips and a blinded set of 27 drugs. The Liver-Chip met IQ consortium qualification criteria and, when protein binding was accounted for, achieved 87% sensitivity and 100% specificity, with the authors estimating an annual industry value of over $3 billion.
## Key findings
- Across a blinded set of 27 known hepatotoxic and non-toxic drugs, the Liver-Chip achieved 87% sensitivity and 100% specificity after accounting for protein binding.
- In the 15 toxic drugs tested using two donors, the Liver-Chip correctly predicted toxicity in 12 out of 15 drugs, yielding 80% sensitivity; the paper reports this was compared with 42% sensitivity for 3D hepatic spheroids and 67% specificity for spheroids.
- Using the protein-binding-corrected analysis, the Spearman correlation with the Garside DILI severity scale was 0.78, versus 0.43 with the lower-threshold, uncorrected approach.
- The economic model estimated a 2.8% NPV uplift for drug development and an annual industry gain of about $3 billion ($2.1B–$3.4B, 95% CI) if Liver-Chips were broadly adopted for small-molecule DILI prediction; extending the approach to four additional Organ-Chip models could yield over $24 billion annually.
## Methods
- The study used 870 Liver-Chips run in five consecutive cycles over 20 weeks, testing 27 drugs in a blinded design with three human hepatocyte donors; drug preparation, dosing, and analysis were split across teams to preserve blinding.
- Liver-Chip performance was assessed using structural and functional endpoints including albumin, ALT, urea, morphology scoring, live/fixed imaging, and gene expression, with toxicity called from concentration- and time-dependent responses across days 1, 3, and 7.
- An economic model extending prior pipeline models was used to estimate how improved preclinical toxicology prediction would change false negative rate (FNR), net present value (NPV), and annual R&D productivity.
## Limitations
- The authors note that the PDMS chip material may be problematic for some small molecules because of non-specific binding, and they recommend checking binding experimentally with an acellular chip; this is a limitation stated in the Discussion.
- The paper notes that only small molecules were assessed, and that performance against large molecules and biologic therapies still needs investigation; this is stated in the Discussion.
- Evident from the text: the study only tested five of six additional IQ-suggested drugs in the second DILI challenge set because one drug was not obtained and another was considered to need a more complex immune configuration.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
8 Valid · 4 Not valid · 19 Not checked · 86 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“This was almost double the sensitivity of 3D hepatic spheroids for the same drug set (42%) based on previously published data31,47,48”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Improved sensitivity for DILI prediction compared to spheroids and animal models
What the sources say
- Disputedcites [31] Proctor WR Utility of spherical human liver microtissues for prediction of clinical drug-induced liver injury Arch. Toxicol. 2017 91 2849 2863 28612260 PMC5515971 sourceExperimental — accuracy not yet measured
In Results (Statistical analysis employing practical fixed thresholds; page unavailable), the paper reports 60.9% sensitivity for its 3D liver spheroids at a 100 μM threshold, not 42%. Its Discussion gives a sensitivity range of 19–61% depending on the threshold. The Results figure of 42 is the number of DILI-positive drugs detected out of 69, not a percentage. (LLM, conf=0.85)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites [47] Hendriks DFG Mechanisms of chronic fialuridine hepatotoxicity as revealed in primary human hepatocyte spheroids Toxicol. Sci. 2019 171 385 395 31505000 source
- Not checked — no full text of the sourcecites [48] Li F Cao L Parikh S Zuo R Three-dimensional spheroids with primary human liver cells and differential roles of Kupffer cells in drug-induced liver injury J. Pharm. Sci. 2020 109 1912 1923 32145211 source
plainn = 2- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“a preclinical model that is currently widely used in pharma and was only able to correctly identify 8 out of the 19 toxic drugs in the set (Table 5).”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Improved sensitivity for DILI prediction compared to spheroids and animal models
What the sources say
- Disputedcites [31] Proctor WR Utility of spherical human liver microtissues for prediction of clinical drug-induced liver injury Arch. Toxicol. 2017 91 2849 2863 28612260 PMC5515971 sourceExperimental — accuracy not yet measured
The Results (Statistical analysis employing practical fixed thresholds; page unavailable) report that the 3D liver microtissue assay tested 69 DILI-positive drugs, identifying 13 to 42 depending on the threshold. The cited paper does not report identifying 8 of 19 toxic drugs; its reported test set and results are different. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites [47] Hendriks DFG Mechanisms of chronic fialuridine hepatotoxicity as revealed in primary human hepatocyte spheroids Toxicol. Sci. 2019 171 385 395 31505000 source
- Not checked — no full text of the sourcecites [48] Li F Cao L Parikh S Zuo R Three-dimensional spheroids with primary human liver cells and differential roles of Kupffer cells in drug-induced liver injury J. Pharm. Sci. 2020 109 1912 1923 32145211 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Importantly, the toxicities of these 8 drugs have been shown to be poorly predicted by hepatic spheroids31,32.”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Improved sensitivity for DILI prediction compared to spheroids and animal models
What the sources say
- Partly supportedcites [31] Proctor WR Utility of spherical human liver microtissues for prediction of clinical drug-induced liver injury Arch. Toxicol. 2017 91 2849 2863 28612260 PMC5515971 sourceExperimental — accuracy not yet measured
The Results section, ‘Comparison of predictive value in PHH and hLiMT across different DILI categories’ (page unavailable), reports false negatives in hepatic microtissues, so the paper supports the point that spheroids missed some drug toxicities. It does not establish that the eight drugs referred to in the citing sentence were the ones missed. (LLM, conf=0.79)
- Partly supportedcites [32] Vorrink SU Zhou Y Ingelman-Sundberg M Lauschke VM Prediction of drug-induced hepatotoxicity using long-term stable primary hepatic 3D spheroid cultures in chemically defined conditions Toxicol. Sci. 2018 163 655 665 29590495 PMC5974779 sourceExperimental — accuracy not yet measured
The Results (page unavailable) report that the spheroid model detected 48 of 70 drugs with human hepatotoxicity liabilities, so it did miss some toxic drugs. The paper does not identify the citing sentence’s particular eight drugs, however, and reports good overall predictive performance rather than describing those eight as a group. (LLM, conf=0.78)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“previously, the same Liver-Chip has been shown to exhibit Phase I and II functional activities that are comparable to freshly isolated human hepatocytes and 3D hepatic spheroids26,30”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Liver-Chip satisfies IQ MPS affiliate guidelines
What the sources say
- Not checked — no full text of the sourcecites [26] Jang K-J Reproducing human and cross-species drug toxicities using a Liver-Chip Sci. Transl. Med. 2019 11 eaax5516 31694927 source
- Partly supportedcites [30] Foster AJ Integrated in vitro models for hepatic safety and metabolism: evaluation of a human Liver-Chip and liver spheroid Arch. Toxicol. 2019 93 1021 1037 30915487 sourceExperimental — accuracy not yet measured
Our copy of Foster et al. (2019) supports the Liver-Chip-vs-3D-spheroid half of the claim: the Discussion (APAP metabolite quantification / Discussion sections) states 'APAP-glucuronide and APAP-sulfate formation is present during the culture period demonstrating phase II metabolism at comparable levels in both systems', and CYP activity profiling (Results, 'CYP activity profiling in Liver-Chips and liver spheroids') says Phase I activity was maintained in both models over the study. The benchmark against human hepatocytes is narrower than the claim states: for the Liver-Chip the Discussion explicitly reports comparability only for CYP2C19, and against 'freshly thawed cryopreserved human hepatocytes' (Brown et al. 2007) rather than freshly isolated cells; the broader hepatocyte comparability statements (including the CYP2E1 36-fold shortfall) are made for the spheroid model, and the paper notes activity levels 'varied between and within experiments' with lower CYP1A2/CYP2D6 at later time points. So a blanket 'Phase I and II activities comparable to freshly isolated human hepatocytes' overstates what this source demonstrates. (LLM, conf=0.72)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“whereas the 3D hepatic spheroids did (only 67% specificity)31”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Improved sensitivity for DILI prediction compared to spheroids and animal models
What the sources say
- Partly supportedcites [31] Proctor WR Utility of spherical human liver microtissues for prediction of clinical drug-induced liver injury Arch. Toxicol. 2017 91 2849 2863 28612260 PMC5515971 sourceExperimental — accuracy not yet measured
The Results section, “Statistical analysis employing practical fixed thresholds” (page unavailable), reports that the 3D liver microtissue assay falsely classified some DILI-negative drugs as toxic. But its reported specificity was 80.5–97.6% across the tabulated thresholds, not 67%. (LLM, conf=0.91)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
55 more claims · 1 with their cited sources checked
Create a free account to see all 117 claims and to verify the 6 references still open.
- It may state two separate claims as one. 43
- Probably not a substantial claim. 21
- The quote only partly states this claim. 2
Citations
Cites
ggplot2: Elegant Graphics for Data Analysis
Wickham, H. (2009) · doi:10.1007/978-0-387-98141-3 · Cited by 14,447
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationCan the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
Dose-Response Analysis Using R
Ritz, C., Baty, F., Streibig, J. C., & Gerhard, D. (2015) · PLOS ONE · doi:10.1371/journal.pone.0146021 · Cited by 3,658
How to improve R&D productivity: the pharmaceutical industry's grand challenge
Paul, S. M., Mytelka, D. S., Dunwiddie, C. T., Persinger, C. C., Munos, B. H., Lindborg, S. R., & Schacht, A. L. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3078 · Cited by 3,566
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationDiagnosing the decline in pharmaceutical R&D efficiency
Scannell, J. W., Blanckley, A., Boldon, H., & Warrington, B. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3681 · Cited by 1,981
Self-citationMale sex identified by global COVID-19 meta-analysis as a risk factor for death and ITU admission
Peckham, H., de Gruijter, N. M., Raine, C., Radziszewska, A., Ciurtin, C., Wedderburn, L. R., Rosser, E. C., Webb, K., & Deakin, C. T. (2020) · Nature Communications · doi:10.1038/s41467-020-19741-6 · Cited by 1,503
Lessons learned from the fate of AstraZeneca's drug pipeline: a five-dimensional framework
Cook, D., Brown, D., Alexander, R., March, R., Morgan, P., Satterthwaite, G., & Pangalos, M. N. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4309 · Cited by 1,344
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Research works printed but not linked: 2
- Redfern WS Impact and frequency of different toxicities throughout the pharmaceutical life cycle Toxicologist 2010 114 1081
- Lloyd, I. Pharma R&D Annual Review 2021, 1–45. (Citeline Informa Pharma Intelligence, 2021).
Cited by
Items 201–300 of 325
The case of the missing mouse—developing cystic fibrosis drugs without using animals
Marshall, L. J., & Conlee, K. M. (2024) · Frontiers in Drug Discovery · doi:10.3389/fddsv.2024.1347246 · Cited by 1
Nontraditional models as research tools: the road not taken
Kiaris, H. (2024) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2024.07.005 · Cited by 2
Isinelli, G., Failla, S., Plebani, R., & Prete, A. (2024) · Medicine International · doi:10.3892/mi.2024.212 · Cited by 1
Towards advanced regenerative therapeutics to tackle cardio-cerebrovascular diseases
Chen, X., Lin, W., & Tortorella, M. D. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100520 · Cited by 1
“…[134 – 136], since the chips could be applied as disease models with close human relevance since the system function as a valuable screening tool using human genome to validate drug targets, which could be used to study efficacy and repurposing of drugs, and predictive toxicology [137,138].”
3D Hepatocyte Model with Composite Nanofibers That Reproduced Human In Vivo Drug Clearance Profiles
Park, R., & Chen, C. (2025) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.5c00149 · Cited by 1
Integrative and Emerging Models in Antibody Research: A Comprehensive Review
Devasani, J. R., Guntuku, G., sarabu, P., Muthyala, M. K. K., Palla, M. S., & Volety, M. S. (2025) · Antibody Therapeutics · doi:10.1093/abt/tbaf018 · Cited by 4
Single-cell omics for nutrition research: an emerging opportunity for human-centric investigations
Cassotta, M., Díaz, Y. A., Cianciosi, D., Yang, B., Qi, Z., Chen, G., Villar, S. G., López, L. A. D., Grosso, G., Quiles, J. L., et al. (2025) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2025.2566387 · Cited by 1
“…technology has shown great promise in fields such as drug development, toxicology, and disease modeling, and is increasingly recognized as a more predictive alternative to animal models for mimicking human-specific physiological and pathological processes (Ewart et al. 2022; Ingber 2020).”
Adefolaju, A., Kram, D. E., Mann, B., Hingtgen, S., & Satterlee, A. (2025) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2025.115736 · Cited by 2
The Application of Microfluidics in Traditional Chinese Medicine Research
Zhu, S., Ke, X., Li, Y., Shu, Z., Zheng, J., Xue, Z., Qi, W., & Xu, B. (2025) · Biosensors · doi:10.3390/bios15120770 · Cited by 1
“As a representative application, organ-on-a-chip precisely reconstructs human organ microenvironments and functions in vitro, providing a more reliable platform for toxicity assessment of TCM and its active components [29,55] (Figure 4d).”
Application and prospects of lung organ-on-a-chip in the development of new drugs
Su, J., Qiu, J., Meng, J., Gong, Y., Xu, Y., & Han, J. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01497-z · Cited by 2
“Before medical institutions or laboratories accepting this technology, it is crucial that the data obtained from OOAC models demonstrate superior performance compared to traditional in vitro experiments, and even superior to some animal models especially in toxicity tests [188].”
Comprehending the Membrane Properties for Emulation in Organs‐on‐a‐Chip
Sathe, T., & Bodas, D. (2025) · Advanced NanoBiomed Research · doi:10.1002/anbr.202500078 · Cited by 1
Hellgren, J., Chouhan, B., Uatay, A., Elgendy, R., Lindgren, J., Toki, N., Bonetti, A., Chaudhari, A., Pryde, K. R., Andersson, P. U., et al. (2025) · Communications Medicine · doi:10.1038/s43856-025-01306-7 · Cited by 1
“ThesemetricsarecomparabletobinaryDILIpredictions obtainedfrombioactivityassayendpointsinPHHspheroids 28,61 , human liver microtissues 30 and liver chips 62,63 .”
When measurement outpaces meaning: Bioimpedance in Organ-on-Chip systems
Wegner, S. (2026) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2026-0001 · Cited by 2
“Legislative and evaluation pathways now conditionally accept Organ-on-Chip evidence [13].”
Bridging the Gap Between Static Histology and Dynamic Organ-on-a-Chip Models
Wang, Z., Naruse, K., & Takahashi, K. (2026) · Pathophysiology · doi:10.3390/pathophysiology33010010 · Cited by 4
“Researchers can reference strategies for constructing specific organ models for New Pathophysiology [Table 1], such as a blood–brain barrier (BBB) platform [60] for studying ischemia–reperfusion injury or a liver model for evaluating drug-induced liver injury (DILI) [61].”
Road map for primary hepatocyte qualification in human liver organ models
Varmazyad, M., Gavlock, D. C., Castiglione, M. W., DeBiasio, R., LaRocca, G. M., Reese, C. E., Vernetti, L. A., Schurdak, M. E., Stern, A. M., Taylor, D. L., et al. (2026) · BMC Methods · doi:10.1186/s44330-026-00058-7 · Cited by 3
“It provides a model that more accurately reflects human biology than traditional approaches, with a reported sensitivity of 100% and specificity of 90% for predicting drug-induced liver injury (DILI) [22].”
The application of experimental models for the drug discovery for digestive tumors
Zheng, L., Shuai, W., Liu, Y., Deng, Y., Bao, J., Hu, X., & Wang, G. (2026) · Molecular Cancer · doi:10.1186/s12943-025-02558-6 · Cited by 4
“The results showed that the liver OoC had a sensitivity of 87% and a specificity of 100% in detecting toxicity [264].”
Organ-on-a-chip systems for osteochondral units: unveiling biomechanical and pathological mechanisms
Liu, Y., Li, J., Gao, F., Zhang, T., Wang, C. M., & Wang, W. (2026) · Biofabrication · doi:10.1088/1758-5090/ae4dbf · Cited by 2
“The controlled environment of OoCs enables researchers to study relevant signaling pathways, analyze complex cell–cell interactions, elucidate disease mechanisms, and evaluate the efficacy of drug treatments [67].”
Simvastatin attenuates endothelial dysfunction in a coronary artery-on-a-chip
Singh, J., Ashok, D., Howard, H., Wise, S. G., & Waterhouse, A. (2026) · Biomaterials Science · doi:10.1039/d6bm00327c · Cited by 1
We need less animal research, better animal research, and animal research done for the right reasons
Ineichen, B. V. (2026) · Journal of Translational Medicine · doi:10.1186/s12967-026-08259-y · Cited by 1
“And in the foresee-able future, they will not fully replace all animal research [25]; although in some contexts they already complement or even supersede it [26].”
New Frontiers of Drug Development Through the Use of New Approach Methodologies
Martínez, M. S. E., Mochel, J. P., Allenspach, K., Zdyrski, C., Krishna, S., & Rusyn, I. (2026) · The AAPS Journal · doi:10.1208/s12248-026-01263-6 · Cited by 2
“The risk of false negatives is typically higher than that of false positives but can be reduced by using chips made from cells obtained from multiple donors (26).”
Shetty, S., Kumar, N. A. N., Kabekkodu, S. P., & Chakrabarty, S. (2026) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2026.189627 · Cited by 6
Hellmold, D., Ziemianowicz, D. S., Ellermann, F., Depperschmidt, P., Appold, M., Omar, A. S., Kurz, J., Krieg-Schneider, F., Hoppe, T. P., Hackenberger, D., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-58939-4 · Cited by 1
“Consequently, the APAP concentrations required to elicit a toxic response in HepG2 spheroids are higher than those observed in more physiologically representative models, which is a recognized limitation of this cell line 19,20,24 .”
Lee, E., Chary, A., Gerelkhuu, Z., Weber, P., Virmani, I., Brugger, B. A., Ribeiro, I. R. S., Brun, E., Lacconi, V., Bang, H., et al. (2026) · Nano Convergence · doi:10.1186/s40580-026-00566-w · Cited by 5
“…New Drugs (ISTAND) pilot program, the FDA accepted the first letter of intent for a human Liver-Chip drug development tool designed to assess drug-induced liver injury (DILI) risk, marking an early step in the drug development tool qualification pathway rather than full qualification [262, 263].”
Gupta, P., Gupta, E., Jain, R., & Dandekar, P. P. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115941 · Cited by 1
Translation of tissue-engineering innovations requires a connected ecosystem
Moisan, A., Kolesky, D. B., Miller, J. S., & Homan, K. A. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00111-y · Cited by 1
Will Labour help us transition away from pre-clinical animal research?
Pound, P., & Ritskes-Hoitinga, M. J. (2024) · BMJ · doi:10.1136/bmj.q1600 · Cited by 1
Creating training opportunities in new approach methodologies for early-career researchers
McCarthy, J., Bailey, J., Baron, R., Krebs, C. E., Singer, M., & Baker, E. (2025) · NAM journal. · doi:10.1016/j.namjnl.2025.100006 · Cited by 4
Mahadik, K., Parvatam, S., & Rao, N. M. (2025) · Journal of Biosciences · doi:10.1007/s12038-025-00529-z · Cited by 1
“Another study showed that the incorporation of liver-on-a-chip in the drug development workflow could generate over USD 3 billion annually for the pharmaceutical industry through increased small-molecule R&D productivity (Ewart et al .”
InfluentialGökçe, F., Kaestli, A. J., Lohasz, C., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.04.06.483760
Tanner, M. G., & Silva, J. D. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824315-2.01045-9
How to Choose Your 3D Assay with Confidence
Lichtenberg, J., Lal-Nag, M., & Wolf, A. (2023) · Genetic Engineering & Biotechnology News · doi:10.1089/gen.43.07.13
Chiara, F. D., Fernández‐Costa, J. M., Ramón‐Azcón, J., Grochala, J., Paleczek, A., Grochala, D., & Rydosz, A. M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15384-6.00007-0
Schueler, J., Sjöman, H., & Kriesi, C. (2024) · Communications Biology · doi:10.1038/s42003-024-05843-0
“Fluidic-based systems like organ-on-a-chip technologies as stand-alone platforms must be combined with novel sensor technologies to speed-up their adoption in drug development, basic science, and precision medicine 35 .”
BackgroundMethodTAKAYAMA, S., & Futai, N. (2024) · The Journal of the Institute of Electrical Engineers of Japan · doi:10.1541/ieejjournal.144.191
The physics and engineering of flow in organ-on-a-chip devices
Wilkinson, J. M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13782-2.00024-3
Microfluidics: Current and Future Perspectives
Wagaman, J. M., Weaver, E., & Lamprou, D. A. (2024) · AAPS introductions in the pharmaceutical sciences · doi:10.1007/978-3-031-60717-2_18
Pillar/Perfusion Plates for Miniature Human Tissue Culture and Predictive Compound Screening
Kang, S. (2024) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc2332528
Role of Microfluidics in Drug Encapsulation for Point-of-care Diagnosis and Prognosis
Mishra, S., Harikrishnan, S., Perwez, A., Wahabi, K., Dahiya, U. R., & Bano, S. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/9781837673476-00190
Benam, K. H. (2024) · Communications Engineering · doi:10.1038/s44172-024-00276-3 · Cited by 4
“In drug development and safety testing, Liver-on-a-Chip models predict human hepatotoxicity and detect cross-species toxicological risks 104,105 .”
Multiomic analysis of Lewisite exposed human dermal equivalent tissues
Dhummakupt, E. S., Jenkins, C. C., Rizzo, G. M., Clay, A. E., Horsmon, J. R., Goralski, T. D. P., Renner, J. A., & Angelini, D. J. (2024) · Chemico-Biological Interactions · doi:10.1016/j.cbi.2024.111295
Mottet, G., Grassart, A., Barthélemy, P., Antignac, C., Arrabal, S., BOURDIN, A. A., Descroix, S., Vos, J. D., Doutriaux, A., Fabrega, Q., et al. (2024) · Therapies · doi:10.1016/j.therap.2024.12.003
Menshikh, K. A., Gobbo, V. A., Nascimben, M., Hannula, M., Cochis, A., Serra, T., Massera, J., Pandit, A. S., & Rimondini, L. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5075043
Case Study #6: Building a Kidney-Chip to Improve Drug Development and Nephrotoxicity Predictions
Jeanty, S. S. F., & Sliz, J. D. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-95680-2.00005-3
Self-citationKrishna, D. V., Chandan, P. B., Venkat, D. S., & Sankar, M. R. (2025) · Wiley eBooks · doi:10.1002/9781394287659.ch18
Non-Invasive Quantification of Viability in Spheroids Using Deep LearningPreprint
Dubinsky, D., Harel, S., Bein, A., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.03.09.642246
“Our experiments demonstrate that NViR outperforms both computational baselines and human experts, specifically pathologists, who are typically employed for similar tasks [29, 30, 31].”
Shrestha, S. (2024) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc2415948
Non-Animal Technologies to Study and Target the Tumour Vasculature and Angiogenesis
Ferrero, E., Hue, J., Ferrarini, M., & Veschini, L. (2025) · Organoids · doi:10.3390/organoids4020012 · Cited by 1
Labos, animaux et mauvaise science
Menache, A. (2025) · Alternatives Non-Violentes · doi:10.3917/anv.215.0012
A microfluidic liver-like model for antiepileptic drugs hepatotoxicity evaluation
Moradi, E., Heirani‐Tabasi, A., Ghiass, M. A., & Solati‐Hashjin, M. (2025) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ae1506 · Cited by 1
Shi, A., Agarwal, P., Liu, Z., & Beringer, P. M. (2025) · Clinical and Translational Science · doi:10.1111/cts.70400
Clonidine compromises human sperm functions
Liu, X., Cui, Y., Qian, R., Li, Y., Hu, Z., Chen, H., Yuan, Y., & Luo, T. (2026) · Reproductive Toxicology · doi:10.1016/j.reprotox.2026.109164
Xiang, Z., & Qin, C. (2025) · Animal Models and Experimental Medicine · doi:10.1002/ame2.70132
Zhang, W., Liu, C., Chen, W., Zhu, Y., Gu, Z., Xue, P., Zhuang, X., Wei, Y., Ye, J., Xu, X., et al. (2026) · Frontiers in Pharmacology · doi:10.3389/fphar.2025.1708719 · Cited by 1
Improving Preclinical Cancer Drug Development Models to Avoid Clinical Failure
Gewirtz, D. A., Teicher, B. A., & Greenberg, E. F. (2026) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-25-3535 · Cited by 1
Microphysiological systems to accelerate and de-risk AAV gene therapy development
Tornabene, P., Berreur, E., Roth, A., & Kasendra, M. J. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115841
Comparison of 2D, 3D In Vitro, and Ex Vivo Platforms for Modeling the Rat Small Intestine
Elias‐Kirma, S., McCoy, R. S. A., van Niekerk, D. C., Stoeger, V., Oldroyd, S., Sumner, E., Savva, A., & Owens, R. M. (2026) · Bioengineering · doi:10.3390/bioengineering13030349
“To fully realize the potential of such 3D bioelectronic systems, rigorous validation is required against both conventional in vitro models and relevant ex vivo or in vivo tissues, ensuring that their functional readouts accurately reflect physiological conditions [11,30].”
Liver-on-a-Chip: Searching for a Balance Between Biomimetics and Functionality
Murashko, A. V., Golubchikov, D. O., Smirnova, O. A., Oleynichenko, K., Nesterova, A., Vosough, M., Svistunov, A., Shpichka, A. I., & Timashev, P. (2026) · Biosensors · doi:10.3390/bios16040191
“The assessment carried out by Ewart et al. [24] showed that LOC had 87% sensitivity and 100% specificity to 27 toxic and non-toxic substances that met the qualification guidelines, which are developed by the Innovation and Quality consortium and define parameters for qualifying preclinical models.”
Hikichi, M., Shimoda, T., & Sato, K. (2026) · Cells · doi:10.3390/cells15070619
“Organ models, including the liver [1–3], kidney [4,5], lung [6], and vasculature [7], have been developed as MPS, with potential applications in disease modeling and personalized medicine.”
Advances in 3D printed blood–brain barrier models
Dong, Y., Wang, D. M., Chen, J., Jeon, T., & Kang, L. (2026) · Biofabrication · doi:10.1088/1758-5090/ae5d73 · Cited by 2
“In a study of 870 human Liver-Chips, the organ-on-a-chip predicted clinical drug-induced liver injury with 87% sensitivity, and portfolio modeling estimated potential R&D productivity gains of around US$3 billion annually if implemented routinely [20].”
Space of Disse on Chip Model for Study of Hepatic Toxicity and Inflammation
Mesic, A. (2025) · theses.fr (ABES) · doi:10.70675/4c19917ez1d50z4ac8za1a5zd5c8d942f244
Whose input should inform training programs’ uses of nonhuman animals?
Feinstein, D. M., & Pawlowski, J. (2026) · Global Surgical Education - Journal of the Association for Surgical Education · doi:10.1007/s44186-025-00437-8
Integrating in vitro and in silico NAMs for enhanced prediction of drug-induced liver injury
Li, T. S., Shrimali, S., Qu, Y., & Tong, W. (2026) · Drug Discovery Today · doi:10.1016/j.drudis.2026.104681 · Cited by 1
Engineering Organ-on-a-Chip Systems for Cancer Immunotherapy: Strategies and Assay Integration
Wang, J., & Wang, Z. (2026) · Bioengineering · doi:10.3390/bioengineering13050492 · Cited by 1
“Reproduced with permission from Ewart et al. [29].”
Ingber, D. E. (2026) · Quarterly Reviews of Biophysics · doi:10.1017/s003358352610016x · Cited by 2
“…four different primary human liver cell types (hepatocytes, liver sinusoidal endothelium, Kupfer cells, and stellate cells) all located in their in vivo-like positions were shown to be many times more accurate at predicting drug-induced liver injury (DILI) than animal models (Ewart et al. , 2022).”
Self-citationMitchell, T., Aihara, T., Tanimoto, K., & Wolvetang, E. J. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.17.725752
Gavlock, D. C., Castiglione, M. W., Wang, A., Varmazyad, M., Vernetti, L. A., Schurdak, M. E., Taylor, D. L., Brown, J. A., & Miedel, M. T. (2026) · Experimental Biology and Medicine · doi:10.3389/ebm.2026.11038
New insights in tumor-on-a-chip models for studying cancer drug resistance
Wang, Y., Shi, L., Li, J., Zhang, X., Ren, J., Jia, Q., Lv, L., Yang, L., Zhang, Z., Yang, J., et al. (2026) · Pathology - Research and Practice · doi:10.1016/j.prp.2026.156562
Johnson, E., Reed, H. R., Thew, A., & Johnson, M. (2026) · NAM journal. · doi:10.1016/j.namjnl.2026.100102 · Cited by 1
Sex as a Design Variable: Organ-on-a-Chip Platforms Embrace Sexual Dimorphism
Kim, E. (2026) · Sex- and Gender-Specific Biomedicine · doi:10.65400/sgbm.2026.1.2.81
Colombo, M. V., Borgström, A., & Filippi, B. G. H. (2026) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2026.2683592
“Hepatotoxicity detection has been evaluated using small drug sets, typically comprising fewer than 30 compounds and as few as three negative controls, resulting in limited or insufficiently robust assessments [62–64].”
Toward clone‐on‐a‐chip: Ethical and legal considerations for organ‐on‐a‐chip evolution
Karabekmez, M. E., Ebrahimi, A., Ghorbanpoor, H., Bassous, N. J., Shin, S. R., Zhang, Y. S., & Avcı, H. (2026) · BMEMat · doi:10.1002/bmm2.70096
Ethical considerations in the use of animals for medical testing: A literature review
Vargas-Chaves, I., Guzmán, D. H., & López-Oliva, J. (2026) · Journal of Animal Behaviour and Biometeorology · doi:10.31893/jabb.2026017
“Economic factors, such as the high cost of organ-on-a-chip systems (Ewart et al., 2022), compete with entrenched institutional practices that favor traditional animal models.”
Mao, X., Cai, M., & Fan, B. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1859058 · Cited by 2
Ma, L., Kam, M. H., Luo, Z., Xi, Y., Ho, K., Luo, Y., Ye, H., Sun, Q., & Peng, Y. (2026) · Food Reviews International · doi:10.1080/87559129.2026.2680272 · Cited by 1
“[5] For foodborne pathogen interaction, intestine-on-chip platforms recapitulate human 3D intestinal architecture and peristaltic motions, allowing real-time observation of enteric pathogen invasion and enterotoxin-induced barrier disruption – areas where animal models suffer from pronounced…”
InfluentialBiomaterial-based Platforms for Modeling the Pre-metastatic Niche
Halim, M. S. A., Nadernezhad, A., Kopecky, C., Hauser, S., Kilian, K. A., & Loessner, D. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-30151-3.00005-x
Balancing efficacy and safety: protein kinase inhibitors and drug-induced liver injury
Shi, Q., & Schnackenberg, L. K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-44173-8.00009-7 · Cited by 1
Jalise, S. Z., Habibi, S., Alizadeh, F., Heidari, F., & Fath‐Bayati, L. (2026) · Journal of Clinical and Experimental Hepatology · doi:10.1016/j.jceh.2026.103599
Human organ-on-a-chip technology as a catalyst for drug discovery
Posey, R. R., Özkan, A., & Ingber, D. E. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115920 · Cited by 2
Self-citationTherapeutic priming of liver regeneration: from mechanisms to ex vivo machine perfusion
Tropp, S. Y., Jaishankar, D., Atkinson, C., & Nadig, S. N. (2026) · Frontiers in Transplantation · doi:10.3389/frtra.2026.1841091 · Cited by 1
“Despite these strengths, most liver-on-a-chip systems have been developed primarily to model liver injury, steatosis, or drug toxicity rather than regeneration itself ( 91 – 94).”
Peptide hormone-based combinational pharmacotherapies for chronic metabolic diseases
Chui, Z. S. W., Xue, Y., Wu, X., & Xu, A. (2026) · Pharmacological Reviews · doi:10.1016/j.pharmr.2026.100150
Kim, Y. W., & Jeong, S. (2026) · BioChip Journal · doi:10.1007/s13206-026-00274-x · Cited by 1
“Continued progress in automation, standardization, and regulatory qualification—supported by recent shifts toward acceptance of non-animal methodologies—will be essential for broader adoption of OoC platforms in drug development pipelines [18, 80].”
InfluentialModeling Hepatic Ischemia–Reperfusion Injury: From 2D and Animal Models to Advanced 3D Platforms
Gasparro, R., Ferraro, C., Cimino, M., Tinnirello, R., Pinzani, M., Miceli, V., & Zito, G. (2026) · Livers · doi:10.3390/livers6050087
“Liver-on-a-chip (LOC) platforms combine 3D constructs with microfluidic perfusion to simulate physiological oxygen gradients, nutrient exchange, and flow dynamics [135–138].”
A modular microfluidic chip unit for multiple-organ-on-chip platform integration and drug screening
Hao, Y.-J., Chen, J.-W., Ke, Y.-W., Zhao, R.-Y., Peng, H.-C., Chu, C.-Y., Yao, B.-Y., Hsiao, W., Hung, M., & Tseng, F. (2026) · The Analyst · doi:10.1039/d6an00510a
3D hepatic spheroid arrays for clearance assessment of small and bRo5 molecules
Mehta, V., Yellanki, R., Molgara, P., Uthukam, V., Kolli, P. R., Sharma, T., Madgula, V., & Karnam, G. (2026) · Drug Metabolism and Disposition · doi:10.1016/j.dmd.2026.100365
An LCD 3D-printed microphysiological system with deflectable extracellular matrix thin films
Nelson, M. D., Tresco, P. A., Razaghian, A., Mercer, C., Yost, C. C., & Gale, B. K. (2026) · Biomedical Materials · doi:10.1088/1748-605x/ae8e15
“Using a similar device architecture, the model was extended to the gut [4], liver [5], and kidney [6], among others [7], and since, numerous researchers have deployed similar models [8, 9].”
Microtechnologies for biological research: From cell culture to drug screening
Fernandes, T., Fernandes, P., & Marques, M. P. C. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36330-6.00005-9
Beadell, B., Yi, S., Roberts, M., Mun, K. S., & Wong‐Beringer, A. (2026) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00254-26
LaFollette, M. R., Blinova, K., Daniel, A. B., Dalmas, D. A., Richardson, E., Marsh, G., Shoemaker, J. T., Seo, J. H., Vukasinovic, J., Word, L. J., et al. (2026) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2026.106189
Tamargo-Rubio, I., Krempel, T., Palasantzas, V. E. J. M., Green, B., Weijer, G., Moerkens, R., van der Woude, C., van IJzendoorn, S. C., Touw, D. J., Hoogerland, J. A., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.07.28.741157
“Spatially separated channels allow for integration of additional cell types in complex co-cultures with independent media [53,54], enabling incorporation of physiologically relevant liver compartments [38,55].”
From nanoengineering to microphysiology: Organ-on-chip platforms for next-generation drug delivery
Akar, Ü., Kestek, E., Çelik, İ., Kozalak, G., & Koşar, A. (2026) · Biophysics Reviews · doi:10.1063/5.0332911
Alshmmari, S. K., Cialla‐May, D., Popp, J., Zourob, M. M., & Ramadan, Q. (2026) · Lab on a Chip · doi:10.1039/d6lc00377j
Historical Development of Cell Culture
Badal, S. (2026) · Springer eBooks · doi:10.1007/978-3-032-28873-8_2
Liver regenerative medicine approaches: Translational strategies for pediatric surgery
Tian, Y., Li, L., Li, X., Lian, H., Chen, Y., & Tam, P. K. H. (2026) · Seminars in Pediatric Surgery · doi:10.1016/j.sempedsurg.2026.151681
Microphysiological Systems and Organ-on-Chip Models
Badal, S. (2026) · Springer eBooks · doi:10.1007/978-3-032-34362-8_8
Human-Relevant 3D In Vitro Liver Spheroids for Preclinical Hepatotoxicity PredictionPreprint
Subia, B., Patel, H., Nathwani, S., Jain, M., & Viswanathan, K. (2026) · Research Square · doi:10.21203/rs.3.rs-10560086/v1
Liver-on-a-chip: Applications for clinical modeling of liver disease using microscale systems
Brooks, N. M., Peczak, A., & Schwartz, R. E. (2026) · Hepatology · doi:10.1097/hep.0000000000001829
Hernández-Castro, J. A., Lussier, F., Malic, L., Geißler, M., Kim, T.-H., Moon, B., Li, K., Zhao, Y., Clime, L., Brassard, D., et al. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115945
Ferraz, L. S., & Linardi, A. (2026) · Pharmacological Research - Reports · doi:10.1016/j.prerep.2026.100102
In Vitro Three-Dimensional Human Liver Model for Drug-Induced Liver and Bile Duct Injury Prediction
Fu, X., Hu, J., Jiang, X., Sun, Y., Xiang, W., Kuang, R., Kang, H., He, L., & Sang, J. (2026) · Toxics · doi:10.3390/toxics14080724
“For instance, Emulate Inc. developed a liver-on-chip system incorporating PHHs, human liver sinusoidal endothelial cells, Kupffer cells, and stellate cells, and applied this platform to DILI prediction across 27 drugs, achieving 87% sensitivity and 100% specificity [32].”
InfluentialNkosi, T., Molefe, L., Dlamini, S., Mokoena, A., & Ndlovu, K. (2026) · International Journal Of Pharmaceutical Research And Allied Sciences · doi:10.51847/fufncppkde
Metadata
- Authors
- Ewart, L., Apostolou, A., Briggs, S. A., Carman, C. V., Chaff, J. T., Heng, A. R., Jadalannagari, S., Janardhanan, J., Jang, K.-J., Joshipura, S. R., Kadam, M. M., Kanellias, M., Kujala, V. J., Kulkarni, G., Le, C. Y., Lucchesi, C., Manatakis, D. V., Maniar, K. K., Quinn, M. E., Ravan, J. S., Rizos, A. C., Sauld, J. F. K., Sliz, J. D., Tien-Street, W., Trinidad, D. R., Velez, J., Wendell, M., Irrechukwu, O., Mahalingaiah, P. K., Ingber, D. E., Scannell, J. W., & Levner, D.
- Affiliations
- Emulate (United States) (US)
- AbbVie (United States) (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ewart, Lorna
- ORCID
- Ewart, Lorna
- Apostolou, Athanasia
- Briggs, Skyler A.
- Carman, Christopher V.
- Chaff, Jake T.
- Heng, Anthony R.
- Jadalannagari, Sushma
- Janardhanan, Jeshina
- Jang, Kyung-Jin
- Joshipura, Sannidhi R.
- Kanellias, Marianne
- Kujala, Ville J.
- Kulkarni, Gauri
- Le, Christopher Y.
- Lucchesi, Carolina
- Manatakis, Dimitris V.
- Maniar, Kairav K.
- Ravan, Joseph S.
- Sliz, Josiah D.
- Tien-Street, William
- Wendell, Max
- Irrechukwu, Onyi
- Mahalingaiah, Prathap Kumar
- Ingber, Donald E.
- Scannell, Jack W.
- Venue
- Communications Medicine
- Published
- 2022-12-06
- Volume
- 2
- Issue
- 1
- Pages
- 154-154
- ISSN
- 2730-664X (ISSN-L)
- PMC
- PMC9727064
- OpenAlex
- W4310952187
- Semantic Scholar
- d2d4fdde294a87ed3651e6b7553d2667221b34ae
- Cited by
- 337
- References
- 56
- Citations by year
- 2026: 124 · 2025: 97 · 2024: 69 · 2023: 45 · 2022: 2
- FWCI
- 48.61
- Type
- journal article
- Language
- en
- Update notices
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Communications Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Drug-Induced Hepatotoxicity and Protection
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Keywords
- organ-on-a-chip, drug-induced liver injury, hepatotoxicity prediction, predictive toxicology, preclinical toxicity testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.