Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index; 13 of the 44 sources its claims cite were checked for support.
Abstract
Conventional preclinical models often miss drug toxicities, meaning the harm these drugs pose to humans is only realized in clinical trials or when they make it to market. This has caused the pharmaceutical industry to waste considerable time and resources developing drugs destined to fail. Organ-on-a-Chip technology has the potential improve success in drug development pipelines, as it can recapitulate organ-level pathophysiology and clinical responses; however, systematic and quantitative evaluations of Organ-Chips' predictive value have not yet been reported. 870 Liver-Chips were analyzed to determine their ability to predict drug-induced liver injury caused by small molecules identified as benchmarks by the Innovation and Quality consortium, who has published guidelines defining criteria for qualifying preclinical models. An economic analysis was also performed to measure the value Liver-Chips could offer if they were broadly adopted in supporting toxicity-related decisions as part of preclinical development workflows. Here, we show that the Liver-Chip met the qualification guidelines across a blinded set of 27 known hepatotoxic and non-toxic drugs with a sensitivity of 87% and a specificity of 100%. We also show that this level of performance could generate over $3 billion annually for the pharmaceutical industry through increased small-molecule R&D productivity. The results of this study show how incorporating predictive Organ-Chips into drug development workflows could…
Overview
CoChat Summary
## TL;DR
This study systematically evaluated a human Liver-Chip for drug-induced liver injury (DILI) prediction using 870 chips and a blinded set of 27 drugs. The Liver-Chip met IQ consortium qualification criteria and, when protein binding was accounted for, achieved 87% sensitivity and 100% specificity, with the authors estimating an annual industry value of over $3 billion.
## Key findings
- Across a blinded set of 27 known hepatotoxic and non-toxic drugs, the Liver-Chip achieved 87% sensitivity and 100% specificity after accounting for protein binding.
- In the 15 toxic drugs tested using two donors, the Liver-Chip correctly predicted toxicity in 12 out of 15 drugs, yielding 80% sensitivity; the paper reports this was compared with 42% sensitivity for 3D hepatic spheroids and 67% specificity for spheroids.
- Using the protein-binding-corrected analysis, the Spearman correlation with the Garside DILI severity scale was 0.78, versus 0.43 with the lower-threshold, uncorrected approach.
- The economic model estimated a 2.8% NPV uplift for drug development and an annual industry gain of about $3 billion ($2.1B–$3.4B, 95% CI) if Liver-Chips were broadly adopted for small-molecule DILI prediction; extending the approach to four additional Organ-Chip models could yield over $24 billion annually.
## Methods
- The study used 870 Liver-Chips run in five consecutive cycles over 20 weeks, testing 27 drugs in a blinded design with three human hepatocyte donors; drug preparation, dosing, and analysis were split across teams to preserve blinding.
- Liver-Chip performance was assessed using structural and functional endpoints including albumin, ALT, urea, morphology scoring, live/fixed imaging, and gene expression, with toxicity called from concentration- and time-dependent responses across days 1, 3, and 7.
- An economic model extending prior pipeline models was used to estimate how improved preclinical toxicology prediction would change false negative rate (FNR), net present value (NPV), and annual R&D productivity.
## Limitations
- The authors note that the PDMS chip material may be problematic for some small molecules because of non-specific binding, and they recommend checking binding experimentally with an acellular chip; this is a limitation stated in the Discussion.
- The paper notes that only small molecules were assessed, and that performance against large molecules and biologic therapies still needs investigation; this is stated in the Discussion.
- Evident from the text: the study only tested five of six additional IQ-suggested drugs in the second DILI challenge set because one drug was not obtained and another was considered to need a more complex immune configuration.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
8 Valid · 4 Not valid · 19 Not checked · 86 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“This was almost double the sensitivity of 3D hepatic spheroids for the same drug set (42%) based on previously published data31,47,48”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Improved sensitivity for DILI prediction compared to spheroids and animal models
What the sources say
- Disputedcites [31] Proctor WR Utility of spherical human liver microtissues for prediction of clinical drug-induced liver injury Arch. Toxicol. 2017 91 2849 2863 28612260 PMC5515971 sourceExperimental — accuracy not yet measured
In Results (Statistical analysis employing practical fixed thresholds; page unavailable), the paper reports 60.9% sensitivity for its 3D liver spheroids at a 100 μM threshold, not 42%. Its Discussion gives a sensitivity range of 19–61% depending on the threshold. The Results figure of 42 is the number of DILI-positive drugs detected out of 69, not a percentage. (LLM, conf=0.85)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites [47] Hendriks DFG Mechanisms of chronic fialuridine hepatotoxicity as revealed in primary human hepatocyte spheroids Toxicol. Sci. 2019 171 385 395 31505000 source
- Not checked — no full text of the sourcecites [48] Li F Cao L Parikh S Zuo R Three-dimensional spheroids with primary human liver cells and differential roles of Kupffer cells in drug-induced liver injury J. Pharm. Sci. 2020 109 1912 1923 32145211 source
plainn = 2- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“a preclinical model that is currently widely used in pharma and was only able to correctly identify 8 out of the 19 toxic drugs in the set (Table 5).”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Improved sensitivity for DILI prediction compared to spheroids and animal models
What the sources say
- Disputedcites [31] Proctor WR Utility of spherical human liver microtissues for prediction of clinical drug-induced liver injury Arch. Toxicol. 2017 91 2849 2863 28612260 PMC5515971 sourceExperimental — accuracy not yet measured
The Results (Statistical analysis employing practical fixed thresholds; page unavailable) report that the 3D liver microtissue assay tested 69 DILI-positive drugs, identifying 13 to 42 depending on the threshold. The cited paper does not report identifying 8 of 19 toxic drugs; its reported test set and results are different. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites [47] Hendriks DFG Mechanisms of chronic fialuridine hepatotoxicity as revealed in primary human hepatocyte spheroids Toxicol. Sci. 2019 171 385 395 31505000 source
- Not checked — no full text of the sourcecites [48] Li F Cao L Parikh S Zuo R Three-dimensional spheroids with primary human liver cells and differential roles of Kupffer cells in drug-induced liver injury J. Pharm. Sci. 2020 109 1912 1923 32145211 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Importantly, the toxicities of these 8 drugs have been shown to be poorly predicted by hepatic spheroids31,32.”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Improved sensitivity for DILI prediction compared to spheroids and animal models
What the sources say
- Partly supportedcites [31] Proctor WR Utility of spherical human liver microtissues for prediction of clinical drug-induced liver injury Arch. Toxicol. 2017 91 2849 2863 28612260 PMC5515971 sourceExperimental — accuracy not yet measured
The Results section, ‘Comparison of predictive value in PHH and hLiMT across different DILI categories’ (page unavailable), reports false negatives in hepatic microtissues, so the paper supports the point that spheroids missed some drug toxicities. It does not establish that the eight drugs referred to in the citing sentence were the ones missed. (LLM, conf=0.79)
- Partly supportedcites [32] Vorrink SU Zhou Y Ingelman-Sundberg M Lauschke VM Prediction of drug-induced hepatotoxicity using long-term stable primary hepatic 3D spheroid cultures in chemically defined conditions Toxicol. Sci. 2018 163 655 665 29590495 PMC5974779 sourceExperimental — accuracy not yet measured
The Results (page unavailable) report that the spheroid model detected 48 of 70 drugs with human hepatotoxicity liabilities, so it did miss some toxic drugs. The paper does not identify the citing sentence’s particular eight drugs, however, and reports good overall predictive performance rather than describing those eight as a group. (LLM, conf=0.78)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“previously, the same Liver-Chip has been shown to exhibit Phase I and II functional activities that are comparable to freshly isolated human hepatocytes and 3D hepatic spheroids26,30”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Liver-Chip satisfies IQ MPS affiliate guidelines
What the sources say
- Not checked — no full text of the sourcecites [26] Jang K-J Reproducing human and cross-species drug toxicities using a Liver-Chip Sci. Transl. Med. 2019 11 eaax5516 31694927 source
- Partly supportedcites [30] Foster AJ Integrated in vitro models for hepatic safety and metabolism: evaluation of a human Liver-Chip and liver spheroid Arch. Toxicol. 2019 93 1021 1037 30915487 sourceExperimental — accuracy not yet measured
Our copy of Foster et al. (2019) supports the Liver-Chip-vs-3D-spheroid half of the claim: the Discussion (APAP metabolite quantification / Discussion sections) states 'APAP-glucuronide and APAP-sulfate formation is present during the culture period demonstrating phase II metabolism at comparable levels in both systems', and CYP activity profiling (Results, 'CYP activity profiling in Liver-Chips and liver spheroids') says Phase I activity was maintained in both models over the study. The benchmark against human hepatocytes is narrower than the claim states: for the Liver-Chip the Discussion explicitly reports comparability only for CYP2C19, and against 'freshly thawed cryopreserved human hepatocytes' (Brown et al. 2007) rather than freshly isolated cells; the broader hepatocyte comparability statements (including the CYP2E1 36-fold shortfall) are made for the spheroid model, and the paper notes activity levels 'varied between and within experiments' with lower CYP1A2/CYP2D6 at later time points. So a blanket 'Phase I and II activities comparable to freshly isolated human hepatocytes' overstates what this source demonstrates. (LLM, conf=0.72)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“whereas the 3D hepatic spheroids did (only 67% specificity)31”
§ Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology > Results > Improved sensitivity for DILI prediction compared to spheroids and animal models
What the sources say
- Partly supportedcites [31] Proctor WR Utility of spherical human liver microtissues for prediction of clinical drug-induced liver injury Arch. Toxicol. 2017 91 2849 2863 28612260 PMC5515971 sourceExperimental — accuracy not yet measured
The Results section, “Statistical analysis employing practical fixed thresholds” (page unavailable), reports that the 3D liver microtissue assay falsely classified some DILI-negative drugs as toxic. But its reported specificity was 80.5–97.6% across the tabulated thresholds, not 67%. (LLM, conf=0.91)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
55 more claims · 1 with their cited sources checked
Create a free account to see all 117 claims and to verify the 6 references still open.
- It may state two separate claims as one. 43
- Probably not a substantial claim. 21
- The quote only partly states this claim. 2
Citations
Cites
ggplot2: Elegant Graphics for Data Analysis
Wickham, H. (2009) · doi:10.1007/978-0-387-98141-3 · Cited by 14,447
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationCan the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
Dose-Response Analysis Using R
Ritz, C., Baty, F., Streibig, J. C., & Gerhard, D. (2015) · PLOS ONE · doi:10.1371/journal.pone.0146021 · Cited by 3,658
How to improve R&D productivity: the pharmaceutical industry's grand challenge
Paul, S. M., Mytelka, D. S., Dunwiddie, C. T., Persinger, C. C., Munos, B. H., Lindborg, S. R., & Schacht, A. L. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3078 · Cited by 3,566
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationDiagnosing the decline in pharmaceutical R&D efficiency
Scannell, J. W., Blanckley, A., Boldon, H., & Warrington, B. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3681 · Cited by 1,981
Self-citationMale sex identified by global COVID-19 meta-analysis as a risk factor for death and ITU admission
Peckham, H., de Gruijter, N. M., Raine, C., Radziszewska, A., Ciurtin, C., Wedderburn, L. R., Rosser, E. C., Webb, K., & Deakin, C. T. (2020) · Nature Communications · doi:10.1038/s41467-020-19741-6 · Cited by 1,503
Lessons learned from the fate of AstraZeneca's drug pipeline: a five-dimensional framework
Cook, D., Brown, D., Alexander, R., March, R., Morgan, P., Satterthwaite, G., & Pangalos, M. N. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4309 · Cited by 1,344
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Research works printed but not linked: 2
- Redfern WS Impact and frequency of different toxicities throughout the pharmaceutical life cycle Toxicologist 2010 114 1081
- Lloyd, I. Pharma R&D Annual Review 2021, 1–45. (Citeline Informa Pharma Intelligence, 2021).
Cited by
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
“Meanwhile, the largest OoCs study to date, in which 780 liver OoC devices were used to evaluate the toxicity risk of a blinded group of 27 known hepatotoxic and nontoxic drugs, showed a sensitivity and specificity of 87% and 100% for liver OoCs, respectively [119].”
BackgroundStrategies to reduce the risks of mRNA drug and vaccine toxicity
Bitounis, D., Jacquinet, E., Rogers, M. A., & Amiji, M. M. (2024) · Nature Reviews Drug Discovery · doi:10.1038/s41573-023-00859-3 · Cited by 224
“Its potential for de-risking purposes has also been established in multiple liver-on-chip drug toxicity studies 228,237,238 .”
Towards in vitro models for reducing or replacing the use of animals in drug testing
Stresser, D. M., Kopec, A. K., Hewitt, P., Hardwick, R. N., Van Vleet, T. R., Mahalingaiah, P. K. S., O’Connell, D., Jenkins, G. J., David, R., Graham, J., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01154-7 · Cited by 94
Self-citationGangwal, A., & Lavecchia, A. (2025) · Drug Discovery Today · doi:10.1016/j.drudis.2025.104360 · Cited by 130
Complex in vitro model: A transformative model in drug development and precision medicine
Wang, L., Hu, D., Xu, J., Hu, J., & Wang, Y. (2024) · Clinical and Translational Science · doi:10.1111/cts.13695 · Cited by 106
“69 The classical chip of TissUse GmbH has a round hole linked by different microfluidic channels (Figure 3b).”
BackgroundRoadblocks confronting widespread dissemination and deployment of Organs on Chips
Alver, C. G., Drabbe, E., Ishahak, M., & Agarwal, A. (2024) · Nature Communications · doi:10.1038/s41467-024-48864-3 · Cited by 74
“Recapitulation of a speci fi c disease microenvironment ensures that the ef fi cacy of a drug — both in terms of its function and its targeting to a speci fi c organ system — can beappropriatelyvalidatedintheearlystagesofdrugdevelopment 34 – 36 .”
Evolution and impact of high content imaging.
Way, G. P., Sailem, H., Shave, S., Kasprowicz, R., & Carragher, N. O. (2023) · SLAS Discovery · doi:10.1016/j.slasd.2023.08.009 · Cited by 67
“HCI also provides readouts in MPS liver models labelled with general cell health, lipid and bile canalicular markers to provide evidence of different mechanisms of hepatotoxicity [62].”
Sunildutt, N., Parihar, P., Salih, A. R. C., Lee, S. H., & Choi, K. H. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1139229 · Cited by 71
Application of new approach methodologies for nonclinical safety assessment of drug candidates
Beilmann, M., Adkins, K., Boonen, H. C. M., Hewitt, P. G., Hu, W., Mader, R., Moore, S., Rana, P., Steger‐Hartmann, T., Villenave, R., et al. (2025) · Nature Reviews Drug Discovery · doi:10.1038/s41573-025-01182-9 · Cited by 85
“Additionally, Emulate’s liver chip exhibited 87% sensitivity and 100% specificity in DILI prediction for 27 known hepatotoxic and non-toxic drugs 134 .”
In vitro immunity: an overview of immunocompetent organ-on-chip models
Morrison, A. I., Sjoerds, M. J., Vonk, L. A., Gibbs, S., & Koning, J. J. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1373186 · Cited by 61
Alghannam, F. S., Alayed, M., Alfihed, S., Sakr, M. A., Almutairi, D., Alshamrani, N., & Fayez, N. A. (2025) · Biosensors · doi:10.3390/bios15020076 · Cited by 71
“For instance, an OoC populated with a patient’s liver cells can predict drug metabolism and identify potential toxicity issues before clinical trials [6].”
The FDA modernisation act 2.0: Bringing non-animal technologies to the regulatory table
Stewart, A. G., Denoyer, D., Gao, X., & Toh, Y. (2023) · Drug Discovery Today · doi:10.1016/j.drudis.2023.103496 · Cited by 54
Biomaterials-Based Antioxidant Strategies for the Treatment of Oxidative Stress Diseases
Pérez-Araluce, M., Jüngst, T., Sanmartín, C., Prósper, F., Plano, D., & Mazo, M. M. (2024) · Biomimetics · doi:10.3390/biomimetics9010023 · Cited by 58
“…those based on human induced pluripotent stem cell (hiPSC)-derived phenotypes, bioengineered technologies (e.g., organ-on-a-chip) and advanced AI-supported computational models, can provide a more reliable bridging between preclinical and clinical stages, as recently promoted by the FDA [222–224].”
BackgroundOuédraogo, G., Alépée, N., Tan, B., & Roper, C. S. (2025) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2025.105904 · Cited by 67
Fluid flow to mimic organ function in 3D in vitro models
Juste-Lanas, Y., Hervás-Raluy, S., García‐Aznar, J. M., & González‐Loyola, A. (2023) · APL Bioengineering · doi:10.1063/5.0146000 · Cited by 57
Flow-Induced Shear Stress Primes NLRP3 Inflammasome Activation in Macrophages via Piezo1
Fish, A., & Kulkarni, A. A. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c18645 · Cited by 43
Modernizing Preclinical Drug Development: The Role of New Approach Methodologies
Mehta, K., Maaß, C., Cucurull-Sanchez, L., Pichardo‐Almarza, C., Subramanian, K., Androulakis, I. P., Gobburu, J. V. S., Schaller, S., & Sherwin, C. M. T. (2025) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.5c00162 · Cited by 56
3D multicellular systems in disease modelling: From organoids to organ-on-chip
Goldrick, C., Guri, I., Herrera-Oropeza, G. E., O’Brien-Gore, C., Roy, E., Wojtynska, M., & Spagnoli, F. M. (2023) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2023.1083175 · Cited by 47
“The controlled environment of organon-chip models allows researchers to study complex cell-cell interactions more easily, investigate relevant signalling pathways, gain insight into disease mechanisms and study the effects of different drug treatments (Ewart et al., 2022).”
BackgroundKasturi, M., Mathur, V., Gadre, M. A., Srinivasan, V., & Vasanthan, K. S. (2023) · Tissue Engineering and Regenerative Medicine · doi:10.1007/s13770-023-00576-3 · Cited by 48
“The major drawback is that the cells have higher proliferation rate which leads to formation of tumours and hence it’s difficult to maintain them in undifferentiating state [206, 207].”
BackgroundHigh‐Scale 3D‐Bioprinting Platform for the Automated Production of Vascularized Organs‐on‐a‐Chip
Fritschen, A., Lindner, N., Scholpp, S., Richthof, P., Dietz, J., Linke, P., Guttenberg, Z., & Blaeser, A. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202304028 · Cited by 45
Lin, C., Huang, X. L., Xue, Y., Jiang, S., Chen, C., Liu, Y., & Chen, K. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.02.017 · Cited by 86
“Overall, organoids and OOAC technology have been steadily adopted as alternatives to animal use, with liver chips being pushed toward commercialization [117].”
Advances in human organs-on-chips and applications for drug screening and personalized medicine
Zhou, C., Li, Z., Lu, K., Liu, Y., Xuan, L., Mao, H., & Wang, X. (2024) · Fundamental Research · doi:10.1016/j.fmre.2023.12.019 · Cited by 45
“Surprisingly, 50% of these drugs were not detected to be hepatotoxic in the 3D liver sphere models [111] .”
Shrestha, S., Lekkala, V. K. R., Acharya, P., Kang, S., Vanga, M. G., & Lee, M. (2024) · Lab on a Chip · doi:10.1039/d4lc00149d · Cited by 42
Ge, Y., Yang, S., Zhang, T., Wan, X., Zhu, Y., Yang, F., Yin, L., Pu, Y., & Liang, G. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.165659 · Cited by 43
Brandauer, K., Schweinitzer, S., Lorenz, A., Krauß, J., Schobesberger, S., Frauenlob, M., & Ertl, P. (2025) · Lab on a Chip · doi:10.1039/d4lc01011f · Cited by 46
Liver-on-chips for drug discovery and development
Mehta, V., Karnam, G., & Madgula, V. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101143 · Cited by 35
“Bonn et al. For sandwich culture of liver hepatocytes and co-culture with other liver specific cells for toxicity prediction [13] V. Mehta et al. demonstrated that conventional PHH culture could only predict clearance of two out of six low-clearance compounds within a 2-fold range [92].”
BackgroundMethodInfluentialChallenges and opportunities for human Organ Chips in FDA assessments and pharma pipelines
Ingber, D. E. (2026) · Cell stem cell · doi:10.1016/j.stem.2025.12.022 · Cited by 44
Self-citationLiver-on-a-chip: Considerations, advances, and beyond
Yang, Z., Liu, X., Cribbin, E. M., Kim, A. M., Li, J. J., & Yong, K. (2022) · Biomicrofluidics · doi:10.1063/5.0106855 · Cited by 36
Pun, S., Prakash, A., Demaree, D., Krummel, D. P., Sciumè, G., Sengupta, S., & Barrile, R. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401876 · Cited by 46
Juguilon, C., Khosravi, R., Radisic, M., & Wu, J. C. (2025) · Circulation Research · doi:10.1161/circresaha.125.325497 · Cited by 47
Li, B., Tang, Y., Huang, Z., Ma, L., Song, J., & Xue, L. (2025) · Protein & Cell · doi:10.1093/procel/pwaf058 · Cited by 57
“With 100% specificity in excluding non-toxic compounds, it demonstrates reliable safety profiling capability for drug development (Ewart et al., 2022).”
Development of lung tissue models and their applications
Petpiroon, N., Netkueakul, W., Sukrak, K., Wang, C., Liang, Y. T., Wang, M., Liu, Y., Li, Q., Kamran, R., Naruse, K., et al. (2023) · Life Sciences · doi:10.1016/j.lfs.2023.122208 · Cited by 44
Yang, J., Khorsandi, D., Trabucco, L., Ahmed, M., Khademhosseini, A., Dokmeci, M. R., Ye, J. Y., & Jucaud, V. (2024) · Small · doi:10.1002/smll.202403560 · Cited by 39
Meyer, S. R., Zhang, C. J., Garcia, M. A., Procario, M. C., Yoo, S., Jolly, A. L., Kim, S., Kim, J., Baek, K., Kersten, R. D., et al. (2024) · Gastro Hep Advances · doi:10.1016/j.gastha.2024.08.004 · Cited by 35
Liu, H., Yin, G., Kohlhepp, M. S., Schumacher, F., Hundertmark, J., Hassan, M. I. A., Heymann, F., Puengel, T., Kleuser, B., Mosig, A. S., et al. (2024) · Advanced Science · doi:10.1002/advs.202403516 · Cited by 30
Opportunities and challenges to engineer 3D models of tumor-adaptive immune interactions
Visalakshan, R. M., Lowrey, M. K., Sousa, M. G. C., Helms, H. R., Samiea, A., Schutt, C. E., Moreau, J. M., & Bertassoni, L. E. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1162905 · Cited by 35
Microfluidic human physiomimetic liver model as a screening platform for drug induced liver injury
Dey, S., Bhat, A., Janani, G., Shandilya, V., Gupta, R., & Mandal, B. B. (2024) · Biomaterials · doi:10.1016/j.biomaterials.2024.122627 · Cited by 29
Microfluidic-based human prostate-cancer-on-chip
Jiang, L., Khawaja, H., Tahsin, S., Clarkson, T. A., Miranti, C. K., & Zohar, Y. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1302223 · Cited by 26
Development of an AI model for DILI-level prediction using liver organoid brightfield images
Tan, S., Ding, Y., Wang, W., Rao, J., Cheng, F., Zhang, Q., Xu, T., Hu, T., Hu, Q., Ye, Z., et al. (2025) · Communications Biology · doi:10.1038/s42003-025-08205-6 · Cited by 26
Lekkala, V. K. R., Kang, S.-Y., Liu, J., Shrestha, S., Acharya, P., Joshi, P., Zolfaghar, M., Lee, M., Vanga, M. G., Jamdagneya, P., et al. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00179 · Cited by 25
A survey to assess animal methods bias in scientific publishing
Krebs, C. E., Lam, A., McCarthy, J., Constantino, H., & Sullivan, K. (2023) · ALTEX · doi:10.14573/altex.2210212 · Cited by 36
“An assessment of 870 Liver-Chips to determine how well they predict drug-induced liver injury found that they outperform conventional animal-based models and could generate over $3 billion annually through increased drug development productivity (Ewart et al., 2022).”
BackgroundA Systematic Review on Organ-on-a-Chip in PDMS or Hydrogel in Dentistry: An Update of the Literature
Pierfelice, T. V., D’Amico, E., Petrini, M., Romano, M., D’Arcangelo, C., Sbordone, L., Barone, A. A., Plebani, R., & Iezzi, G. (2024) · Gels · doi:10.3390/gels10020102 · Cited by 30
Hu, W., Wang, Y., Han, J., Zhang, W., Chen, J., Li, X., & Wang, L. (2025) · Biomaterials Science · doi:10.1039/d4bm01273a · Cited by 30
Xeno-Free 3D Bioprinted Liver Model for Hepatotoxicity Assessment
Ali, A. S. M., Berg, J., Röhrs, V., Wu, D., Hackethal, J., Braeuning, A., Woelken, L., Rauh, C., & Kurreck, J. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25031811 · Cited by 27
Animal Models of Human Disease
Green, S. (2024) · Cambridge University Press eBooks · doi:10.1017/9781009025836 · Cited by 31
Pal, S., Shimshoni, E., Flores-Torres, S., Kong, M., Tai, K., Sangwan, V., Bertos, N., Bailey, S. D., Bérubé, J., Ingber, D. E., et al. (2025) · Journal of Translational Medicine · doi:10.1186/s12967-025-06593-1 · Cited by 30
Self-citationRenal Organic Anion Transporters 1 and 3 In Vitro: Gone but Not Forgotten
Caetano-Pinto, P., & Stahl, S. H. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms242015419 · Cited by 24
“Nowadays, animal experimentation for drug testing purposes is gradually being replaced by more complex in vitro models and comprehensive approaches to reduce the use of animals in research [18,19].”
BackgroundHuman‐based new approach methodologies to accelerate advances in nutrition research
Cassotta, M., Cianciosi, D., Elexpuru-Zabaleta, M., Elío, I., Cano, S. S., Giampieri, F., & Battino, M. A. (2024) · Food Frontiers · doi:10.1002/fft2.369 · Cited by 28
“…are already yielding profuse and meaningful human-relevant data and promising results in several fields (Barrile et al., 2018; Ewart et al., 2022; Kamali et al., 2022; Passini et al., 2017; Pistollato et al., 2021,…”
BackgroundKaden, T., Graf, K., Rennert, K., Li, R., Mosig, A. S., & Raasch, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-40004-z · Cited by 28
“Likewise, several in vitro studies have recently suggested a hepatotoxic effect of TVX without LPS using different liver models 24,25,27,39 revealing direct KC activation by TVX and the involvement of intrinsic toxicity mechanisms.”
BackgroundMethodAkhtar, Z. B. (2024) · Journal of Electronics Electromedical Engineering and Medical Informatics · doi:10.35882/jeeemi.v6i1.351 · Cited by 43
How organ-on-a-chip is advancing cancer research and oncology - a cancer hallmarks’ perspective
Avula, L. R., & Grodzinski, P. A. (2024) · Frontiers in Lab on a Chip Technologies · doi:10.3389/frlct.2024.1487377 · Cited by 26
Organs-on-chips: a decade of innovation
Strelez, C., Jiang, H. Y., & Mumenthaler, S. M. (2023) · Trends in biotechnology · doi:10.1016/j.tibtech.2023.01.004 · Cited by 27
Fish, A., Forster, J., Malik, V., & Kulkarni, A. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c18845 · Cited by 20
Complex in vitro models positioned for impact to drug testing in pharma: a review
Kang, S., Chen, E. C., Cifuentes, H., Co, J. Y., Cole, G., Graham, J. C., Hsia, I., Kiyota, T., Klein, J. A., Kroll, K. T., et al. (2024) · Biofabrication · doi:10.1088/1758-5090/ad6933 · Cited by 25
“As part of this assessment, cytotoxicity or perturbation of hepatocyte function is typically considered as summarized in table 14 [247, 248, 253–255].”
It’s Time to Review the Three Rs, to Make them More Fit for Purpose in the 21st Century
Bailey, J. (2024) · Alternatives to Laboratory Animals · doi:10.1177/02611929241241187 · Cited by 25
“56,57 There are many more examples of this type of failing, all of which constitute substantial evidence for a paradigm shift in how we should approach research and testing.”
BackgroundMethodMiller, C. P., Fung, M., Jaeger-Ruckstuhl, C. A., Xu, Y., Warren, E. H., Akilesh, S., & Tykodi, S. S. (2023) · Neoplasia · doi:10.1016/j.neo.2023.100948 · Cited by 19
“The search for more robust in vitro tumor models has stimulated interest in economical human microphysiological systems to better predict efficacy and toxicity [4].”
BackgroundPerry, A., Hadad, N., Chatterjee, E., Ramos, M. J., Farber‐Eger, E. H., Roshani, R., Stolze, L. K., Betti, M. J., Zhao, S., Huang, S., et al. (2024) · Cell Reports Medicine · doi:10.1016/j.xcrm.2024.101871 · Cited by 23
Self-citationIntegrating Liver-Chip data into pharmaceutical decision-making processes
Levner, D., & Ewart, L. C. (2023) · Expert Opinion on Drug Discovery · doi:10.1080/17460441.2023.2255127 · Cited by 20
“Fortunately, recent findings indicate that the Liver-Chip may be highly capable in detecting hepatotoxic drugs that animal models permit into the clinic [25], suggesting that the Liver-Chip may be a valuable addition to drug development work-flows to be used alongside animal models.”
BackgroundMethodResultInfluentialSelf-citationLim, A. Y., Kato, Y., Sakolish, C., Valdiviezo, A., Han, G., Bajaj, P., Stanko, J. P., Ferguson, S., Villenave, R., Hewitt, P. G., et al. (2023) · Bioengineering · doi:10.3390/bioengineering10101195 · Cited by 23
“…their model’s utility via testing of a large number of liver-toxic compounds and establishing “performance” against human liver toxicity data [32,33], while others have taken a lab-to-lab comparison approach to focus on reproducibility, robustness, and determination of the potential…”
Backgroundda Silva, G. G., Sacomani, D. P., de Carvalho, B. G., Porcionatto, M. A., Gobbi, Â. L., Lima, R. S., & de la Torre, L. G. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c02221 · Cited by 26
Organoids and organ-on-chip technology for investigating host-microorganism interactions
Walocha, R., Kim, M., Wong-Ng, J., Gobaa, S., & Sauvonnet, N. (2024) · Microbes and Infection · doi:10.1016/j.micinf.2024.105319 · Cited by 21
Chim, S. M., Howell, K., Kokkosis, A. G., Zambrowicz, B., Karalis, K. P., & Pavlopoulos, E. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16101314 · Cited by 23
“Recent advancements in human microphysiological systems (MPS) and Organ-Chip technologies are emerging as promising approaches to achieve this goal and provide robust and reproducible systems for disease modeling and drug development [6,7,28–35].”
BackgroundNavigating pharmaceuticals: microfluidic devices in analytical and formulation sciences
Das, A., & Prajapati, P. (2025) · Discover Chemistry. · doi:10.1007/s44371-025-00133-y · Cited by 26
“For example, AstraZeneca has used liver-on-chip models to screen drug candidates, enhancing their ability to identify compounds with potential toxicity before clinical trials [79, 80].”
Are New Approach Methodologies (NAMs) the Holy Grail of toxicology?
Jaeschke, H., & Ramachandran, A. (2025) · Toxicological Sciences · doi:10.1093/toxsci/kfaf113 · Cited by 23
New approach methodologies (NAMs) for drug-induced liver injury (DILI): Where are we now?
Shrimali, S., Chen, M., Li, D., & Tong, W. (2025) · Drug Discovery Today · doi:10.1016/j.drudis.2025.104452 · Cited by 20
A large-scale human toxicogenomics resource for drug-induced liver injury prediction
Bergen, V., Kodella, K. R., Srikrishnan, S., Barrandon, O., Anderson, S., Rogers-Grazado, M., Fowler, C. C., Beyene, H., Robichaud, N., Fulton, T., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-65690-3 · Cited by 33
“High-content imaging in 3D models, such as those by Walker et al. 34 and Ewart et al. 35 , achieves similar performance on small, curated panels (Walker: 23/27 vs. 23/27; Ewart: 11/14 vs. 13/14).”
Industry Adoption of Organoids and Organs‐on‐Chip Technology: Toward a Paradox of Choice
Homan, K. A. (2023) · Advanced Biology · doi:10.1002/adbi.202200334 · Cited by 22
Wilkinson, J. M. (2023) · Frontiers in Toxicology · doi:10.3389/ftox.2023.1170193 · Cited by 18
“Proving the efficacy of the OOAC technology is now the main focus of at least one of the development companies (Ewart et al., 2022) In a recent study, Emulate analysed the ability of their commercial Liver Chip model to predict Drug Induced Liver Injury (DILI) caused by small molecules.”
BackgroundMethodInfluentialBioprinting of Cardiac Tissue in Space: Where Are We?
Tabury, K., Rehnberg, E., Baselet, B., Baatout, S., & Moroni, L. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202203338 · Cited by 20
Immune‐related adverse events of antibody‐based biological medicines in cancer therapy
Rajagopal, D., MacLeod, E., Corogeanu, D., & Vessillier, S. (2024) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.18470 · Cited by 22
“189 Despite immense progress, the delivery of these approaches is extremely complex.”
BackgroundVascular microphysiological systems (MPS): biologically relevant and potent models
Breuil, L., Kitada, A., Yadav, S., Zhou, H., Fujimoto, K., & Yokokawa, R. (2025) · Lab on a Chip · doi:10.1039/d5lc00014a · Cited by 19
Tamargo-Rubio, I., Simpson, A. B., Hoogerland, J. A., & Fu, J. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1223108 · Cited by 22
“The development of liveron-a-chip models utilizing primary hepatocytes, the current ‘gold standard’, has been extensively explored (Apte & Krishnamurthy, 2011; Docci et al., 2022; Ewart et al., 2022).”
BackgroundMethodInfluentialAdvanced tissue engineering for in vitro drug safety testing
Owens, R. M. (2023) · MRS Communications · doi:10.1557/s43579-023-00421-7 · Cited by 20
“[36] The paper, published in December 2022 nicely coincided with the FDA’s announcement.”
BackgroundMcGill, M. R., & Curry, S. C. (2023) · Livers · doi:10.3390/livers3040039 · Cited by 16
Parvatam, S., Pamies, D., Pistollato, F., Beken, S., Mariappan, I., Roth, A. B., Piergiovanni, M., Maisonneuve, B. G. C., Ewart, L. C., Majumder, A., et al. (2023) · Stem Cell Reports · doi:10.1016/j.stemcr.2023.11.008 · Cited by 17
Self-citationGallegos-Martínez, S., Buentello, D. C., Pérez-Álvarez, K. A., Lara-Mayorga, I. M., Aceves-Colin, A. E., Zhang, Y. S., Santiago, G. T., & Álvarez, M. M. (2024) · Biofabrication · doi:10.1088/1758-5090/ad5765 · Cited by 17
“Nevertheless, the access to ToCs (and organ-on-chips in general) is far from widespread among the biomedical community [21–23], where only a limited number of platforms are commercially available for the development of new organ/ToCs applications [ 24, 25].”
Haber, L. T., Bradley, M. A., Buerger, A. N., Behrsing, H. P., Burla, S., Clapp, P. W., Dotson, G. S., Fisher, C., Genco, K. R., Kruszewski, F. H., et al. (2024) · Frontiers in Toxicology · doi:10.3389/ftox.2024.1431790 · Cited by 19
“A recent paper on liver-chip methods provides one possible model approach for standardization of in vitro methods, including considerations of both technical and cost aspects (Ewart et al., 2022).”
MethodAdvancements of paper-based microfluidics and organ-on-a-chip models in cosmetics hazards
Pai, S., Binu, A., Lavanya, G. S., Harikumar, M., Herga, S. K., Citartan, M., & Mani, N. K. (2025) · RSC Advances · doi:10.1039/d4ra07336c · Cited by 20
“Ewart et al. , 2022 have evaluated the use of liver-on-a-chip for studying toxicology in drug development processes.”
Myszczyszyn, A., Muench, A., Lehmann, V., Sinnige, T., van Steenbeek, F. G., Bouwmeester, M., Samsom, R.-A., Keuper-Navis, M., van der Made, T. K., Kogan, D., et al. (2025) · Biofabrication · doi:10.1088/1758-5090/adc3ce · Cited by 14
“Indeed, a performance assessment of 870 commercially manufactured (from Emulate, Inc. ) human liver-like chips confirmed that they are predictive for acute drug-induced liver injury and can be incorporated into pre-clinical development for hepatotoxicity testing [84].”
Alternatives to animal testing to assess MASH drugs and hepatotoxicity
Brenner, D. A. (2023) · Hepatology · doi:10.1097/hep.0000000000000669 · Cited by 15
Cell Painting for cytotoxicity and mode-of-action analysis in primary human hepatocytes
Ewald, J., Titterton, K., Bäuerle, A., Beatson, A., Boiko, D. A., Cabrera, Á. A., Cheah, J. H., Cimini, B. A., Gorissen, B. L., Harrill, J., et al. (2026) · Cell Systems · doi:10.1016/j.cels.2026.101566 · Cited by 23
Luan, Q., Pulido, I., Isagirre, A., Carretero, J., Zhou, J., Shimamura, T., & Papautsky, I. (2024) · Lab on a Chip · doi:10.1039/d3lc01044a · Cited by 21
Opportunities for Microphysiological Systems in Toxicity Testing of New Drug Modalities
Maulana, T. I., Wevers, N. R., Kristoforus, T., Chandler, M. R., Lanz, H. L., Joore, J., Vulto, P., Villenave, R., Kustermann, S., Loskill, P., et al. (2024) · The Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-061724-080621 · Cited by 24
Integrated Patient Digital and Biomimetic Twins for Precision Medicine: A Perspective
Miedel, M. T., Schurdak, M. E., Stern, A. M., Soto–Gutiérrez, A., Strobl, E. V., Behari, J., & Taylor, D. L. (2025) · Seminars in Liver Disease · doi:10.1055/a-2649-1560 · Cited by 23
Advances and applications of organ-on-a-chip technology
Kong, J. S., Kim, J., Jang, J., & Cho, D.-W. (2026) · Cell Reports Methods · doi:10.1016/j.crmeth.2026.101361 · Cited by 20
“11,12 The most comprehensive validation study demonstrated that the OOC technology could achieve 87% sensitivity and 100% specificity for DILI prediction, 125 compared to animal models that correctly predict human outcomes only about 50% of the time-essentially random chance.”
Microfluidics: Insights into Intestinal Microorganisms
Qi, P., Lv, J., Yan, X.-D., Bai, L., & Zhang, L. (2023) · Microorganisms · doi:10.3390/microorganisms11051134 · Cited by 14
Organ-On-A-Chip (OOC) Image Dataset for Machine Learning and Tissue Model Evaluation
Movčana, V., Strods, A., Narbute, K., Rūmnieks, F., Rimša, R., Mozoļevskis, G., Ivanovs, M., Kadiķis, R., Zviedris, K. G., Leja, L., et al. (2024) · Data · doi:10.3390/data9020028 · Cited by 16
Tackling the challenges of new approach methods for predicting drug effects from model systems
Pang, P. D., Ahmed, S. M., Nishiga, M., Stockbridge, N., & Wu, J. C. (2024) · Nature Reviews Drug Discovery · doi:10.1038/d41573-024-00081-9 · Cited by 16
“For example, an organ-on-chip system based on primary human hepatocytes effectively identified drugs that proved to be hepatotoxic in clinical use despite tests of these drugs in animal models indicating that they had an appropriate therapeutic window 4 .”
Bai, H., Olson, K. N. P., Pan, M., Marshall, T., Singh, H., Ma, J., Gilbride, P., Yuan, Y., McCormack, J., Si, L., et al. (2023) · Advanced Science · doi:10.1002/advs.202304332 · Cited by 14
Budharaju, H., Singh, R. K., & Kim, H. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.07.006 · Cited by 37
Ferrari, I., Limiti, E., Giannitelli, S. M., Trombetta, M., Rainer, A., D’Amelio, M., Barbera, L. L., & Gori, M. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26199478 · Cited by 15
Standard: human liver-on-a-chip
Liu, H., Zhang, X., Wang, Y., Zhang, M., Wang, P., Shang, J., Li, Z., Gong, L., Xie, X., Liu, D., et al. (2025) · Cell Regeneration · doi:10.1186/s13619-025-00226-0 · Cited by 12
Shrimali, S., Li, D., Knox, B., Tong, W., & Ning, B. (2025) · Drug Metabolism and Disposition · doi:10.1016/j.dmd.2025.100187 · Cited by 15
Lamouline, A., Bersini, S., & Moretti, M. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1135401 · Cited by 15
“For example, a recent study on liver toxicology showed that an organ-on-a-chip model outperformed conventional models, highlighting hepatotoxic reactions that were missed in animal models (17).”
BackgroundBeyond the hype and toward application: liver complex in vitro models in preclinical drug safety
Jadalannagari, S., & Ewart, L. C. (2024) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2024.2328794 · Cited by 15
“In the short term, researchers working with liver CIVMs focus measurement of albumin or ALT and AST, but urea is a good marker of mitochondrial function and has been measured in liver CIVMs [45,62,97] while miR122, which signals hepatocyte damage, has also been measured in liver CIVMs [98,99].”
Self-citationReconstitution of human tissue barrier function for precision and personalized medicine
Kim, J., Yoon, T., Lee, S. W., Kim, P. J., & Kim, Y. (2024) · Lab on a Chip · doi:10.1039/d4lc00104d · Cited by 16
Targeted Cancer Therapy‐on‐A‐Chip
Abed, H., Radha, R., Anjum, S., Paul, V., AlSawaftah, N., Pitt, W. G., Ashammakhi, N. A., & Husseini, G. A. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202400833 · Cited by 13
Organ‐on‐Chip: The Future of Nutrition Research in a One Health World
Cassotta, M., Elexpuru-Zabaleta, M., Cano, S. S., Díaz, Y. A., Giampieri, F., Xiaobo, Z., Zhang, D., Grosso, G., & Battino, M. A. (2025) · Food Frontiers · doi:10.1002/fft2.70000 · Cited by 12
Pérez‐Calixto, M., Peto‐Gutiérrez, C., Shapiro, A., Huerta, L., Hautefeuille, M., Macías‐Silva, M., Pérez‐Calixto, D., & Vázquez‐Victorio, G. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202404686 · Cited by 12
Microphysiological Models for Mechanistic-Based Prediction of Idiosyncratic DILI
Stern, S., Wang, H., & Sadrieh, N. K. (2023) · Cells · doi:10.3390/cells12111476 · Cited by 14
Metadata
- Authors
- Ewart, L., Apostolou, A., Briggs, S. A., Carman, C. V., Chaff, J. T., Heng, A. R., Jadalannagari, S., Janardhanan, J., Jang, K.-J., Joshipura, S. R., Kadam, M. M., Kanellias, M., Kujala, V. J., Kulkarni, G., Le, C. Y., Lucchesi, C., Manatakis, D. V., Maniar, K. K., Quinn, M. E., Ravan, J. S., Rizos, A. C., Sauld, J. F. K., Sliz, J. D., Tien-Street, W., Trinidad, D. R., Velez, J., Wendell, M., Irrechukwu, O., Mahalingaiah, P. K., Ingber, D. E., Scannell, J. W., & Levner, D.
- Affiliations
- Emulate (United States) (US)
- AbbVie (United States) (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ewart, Lorna
- ORCID
- Ewart, Lorna
- Apostolou, Athanasia
- Briggs, Skyler A.
- Carman, Christopher V.
- Chaff, Jake T.
- Heng, Anthony R.
- Jadalannagari, Sushma
- Janardhanan, Jeshina
- Jang, Kyung-Jin
- Joshipura, Sannidhi R.
- Kanellias, Marianne
- Kujala, Ville J.
- Kulkarni, Gauri
- Le, Christopher Y.
- Lucchesi, Carolina
- Manatakis, Dimitris V.
- Maniar, Kairav K.
- Ravan, Joseph S.
- Sliz, Josiah D.
- Tien-Street, William
- Wendell, Max
- Irrechukwu, Onyi
- Mahalingaiah, Prathap Kumar
- Ingber, Donald E.
- Scannell, Jack W.
- Venue
- Communications Medicine
- Published
- 2022-12-06
- Volume
- 2
- Issue
- 1
- Pages
- 154-154
- ISSN
- 2730-664X (ISSN-L)
- PMC
- PMC9727064
- OpenAlex
- W4310952187
- Semantic Scholar
- d2d4fdde294a87ed3651e6b7553d2667221b34ae
- Cited by
- 337
- References
- 56
- Citations by year
- 2026: 124 · 2025: 97 · 2024: 69 · 2023: 45 · 2022: 2
- FWCI
- 48.61
- Type
- journal article
- Language
- en
- Update notices
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Communications Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Drug-Induced Hepatotoxicity and Protection
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Keywords
- organ-on-a-chip, drug-induced liver injury, hepatotoxicity prediction, predictive toxicology, preclinical toxicity testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.