The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Ultra-flexible Piezoelectric Devices Integrated with Heart to Harvest the Biomechanical Energy
Open accessAbstract
Power supply for medical implantable devices (i.e. pacemaker) always challenges not only the surgery but also the battery technology. Here, we report a strategy for energy harvesting from the heart motion by using ultra-flexible piezoelectric device based on lead zirconate titanate (PZT) ceramics that has most excellent piezoelectricity in commercial materials, without any burden or damage to hearts. Experimental swine are selected for in vivo test with different settings, i.e. opened chest, close chest and awake from anesthesia, to simulate the scenario of application in body due to their hearts similar to human. The results show the peak-to-peak voltage can reach as high as 3 V when the ultra-flexible piezoelectric device is fixed from left ventricular apex to right ventricle. This demonstrates the possibility and feasibility of fully using the biomechanical energy from heart motion in human body for sustainably driving implantable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotechnology‐Enabled Energy Harvesting for Self‐Powered Micro‐/Nanosystems
Wang, Z. L., & Wu, W. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201656 · Cited by 1,063
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Self-citationYang, Y., Zhang, H., Lin, Z.-H., Zhou, Y. S., Jing, Q., Su, Y., Yang, J., Chen, J., Hu, C., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn403838y · Cited by 798
Riemer, R., & Shapiro, A. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-22 · Cited by 379
Evaluation of motions and actuation methods for biomechanical energy harvesting
Niu, P., Chapman, P., Riemer, R., & Zhang, X. (2005) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1355442 · Cited by 117
Cited by
High-Performance Piezoelectric Energy Harvesters and Their Applications
Yang, Z., Zhou, S., Zu, J., & Inman, D. (2018) · Joule · doi:10.1016/j.joule.2018.03.011 · Cited by 1,264
Safaei, M., Sodano, H. A., & Anton, S. R. (2019) · Smart Materials and Structures · doi:10.1088/1361-665x/ab36e4 · Cited by 874
“KGaA, Weinheim), (e) PZT-based flexible heart harvester (reproduced from [408].”
BackgroundMethodInfluentialFlexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Recent Progress on Piezoelectric and Triboelectric Energy Harvesters in Biomedical Systems
Zheng, Q., Shi, B., Li, Z., & Wang, Z. L. (2017) · Advanced Science · doi:10.1002/advs.201700029 · Cited by 566
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Piezoelectric materials for flexible and wearable electronics: A review
Wu, Y., Ma, Y., Zheng, H., & Ramakrishna, S. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.110164 · Cited by 521
Harvesting ambient wind energy with an inverted piezoelectric flag
Orrego, S., Shoele, K., Ruas, A., Doran, K., Caggiano, B., Mittal, R., & Kang, S. H. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.03.016 · Cited by 435
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Zhou, H., Zhang, Y., Qiu, Y., Wu, H., Qin, W., Liao, Y., Yu, Q., & Cheng, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112569 · Cited by 370
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Sensing, Computing, and Communications for Energy Harvesting IoTs: A Survey
Ma, D., Lan, G., Hassan, M., Hu, W., & Das, S. K. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2962526 · Cited by 336
Piezoelectric energy harvesters for biomedical applications
Ali, F., Raza, W., Li, X., Gul, H., & Kim, K.-H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.012 · Cited by 300
Hydrogels for Flexible Electronics
Zhang, Y., Tan, Y., Lao, J., Gao, H., & Yu, J. (2023) · ACS Nano · doi:10.1021/acsnano.3c02897 · Cited by 291
Implantable Energy‐Harvesting Devices
Shi, B., Li, Z., & Fan, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801511 · Cited by 290
Piezoelectric energy harvesting systems for biomedical applications
Panda, S., Hajra, S., Mistewicz, K., In-na, P., Sahu, M., Rajaitha, P. M., & Kim, H. J. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107514 · Cited by 269
In Vivo Self‐Powered Wireless Transmission Using Biocompatible Flexible Energy Harvesters
Kim, D. H., Shin, H. J., Lee, H., Jeong, C. K., Park, H., Hwang, G., Lee, H., Joe, D. J., Han, J. H., Lee, S. H., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700341 · Cited by 245
Lyu, H., John, M., Burkland, D., Greet, B., Post, A., Babakhani, A., & Razavi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-59017-z · Cited by 51
Metadata
- Authors
- Lu, B., Chen, Y., Ou, D., Chen, H., Diao, L., Zhang, W., Zheng, J., Ma, W., Sun, L., & Feng, X.
- Venue
- Scientific Reports
- Published
- 2015-11-05
- Volume
- 5
- Issue
- 1
- Pages
- 16065-16065
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2404267834
- Cited by
- 182
- References
- 5
- FWCI
- 15.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.