The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Ultrasound modulates ion channel currents
Open accessAbstract
Transcranial focused ultrasound (US) has been demonstrated to stimulate neurons in animals and humans, but the mechanism of this effect is unknown. It has been hypothesized that US, a mechanical stimulus, may mediate cellular discharge by activating mechanosensitive ion channels embedded within cellular membranes. To test this hypothesis, we expressed potassium and sodium mechanosensitive ion channels (channels of the two-pore-domain potassium family (K2P) including TREK-1, TREK-2, TRAAK; Na V 1.5) in the Xenopus oocyte system. Focused US (10 MHz, 0.3–4.9 W/cm 2) modulated the currents flowing through the ion channels on average by up to 23%, depending on channel and stimulus intensity. The effects were reversible upon repeated stimulation and were abolished when a channel blocker (ranolazine to block Na V 1.5, BaCl 2 to block K2P channels) was applied to the solution. These data reveal at the single cell level that focused US modulates the activity of specific ion channels to mediate transmembrane currents. These findings open doors to investigations of the effects of US on ion channels expressed in neurons, retinal cells, or cardiac cells, which may lead to important medical applications. The findings may also pave the way to the development of sonogenetics: a non-invasive, US-based analogue of optogenetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316
Piezo proteins are pore-forming subunits of mechanically activated channels
Coste, B., Xiao, B., Santos, J. S., Syeda, R., Grandl, J., Spencer, K. S., Kim, S. E., Schmidt, M., Mathur, J., Dubin, A. E., et al. (2012) · Nature · doi:10.1038/nature10812 · Cited by 1,167
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977
Fregni, F., & Pascual-Leone, A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0530 · Cited by 823
Piezo2 is required for Merkel-cell mechanotransduction
Woo, S.-H., Ranade, S., Weyer, A. D., Dubin, A. E., Baba, Y., Qiu, Z., Petrus, M., Miyamoto, T., Reddy, K., Lumpkin, E. A., et al. (2014) · Nature · doi:10.1038/nature13251 · Cited by 779
Remote control of ion channels and neurons through magnetic-field heating of nanoparticles
Huang, H., Delikanli, S., Zeng, H., Ferkey, D. M., & Pralle, A. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.125 · Cited by 762
Primary structure and functional expression of the beta 1 subunit of the rat brain sodium channel
Isom, L., De Jongh, K., Patton, D., Reber, B., Offord, J., Charbonneau, H., Walsh, K., Goldin, A., & Catterall, W. (1992) · Science · doi:10.1126/science.1375395 · Cited by 711
Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 707
A mammalian two pore domain mechano-gated S-like K+ channel
Patel, A. J. (1998) · The EMBO Journal · doi:10.1093/emboj/17.15.4283 · Cited by 641
Cited by
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Folloni, D., Verhagen, L., Mars, R. B., Fouragnan, E., Constans, C., Aubry, J.-F., Rushworth, M. F. S., & Sallet, J. (2019) · Neuron · doi:10.1016/j.neuron.2019.01.019 · Cited by 401
Non-invasive transcranial ultrasound stimulation for neuromodulation
Darmani, G., Bergmann, T. O., Butts Pauly, K., Caskey, C. F., de Lecea, L., Fomenko, A., Fouragnan, E., Legon, W., Murphy, K. R., Nandi, T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.12.010 · Cited by 332
Offline impact of transcranial focused ultrasound on cortical activation in primates
Verhagen, L., Gallea, C., Folloni, D., Constans, C., Jensen, D. E., Ahnine, H., Roumazeilles, L., Santin, M., Ahmed, B., Lehericy, S., et al. (2019) · eLife · doi:10.7554/elife.40541 · Cited by 329
Transcranial focused ultrasound neuromodulation of the human primary motor cortex
Legon, W., Bansal, P., Tyshynsky, R., Ai, L., & Mueller, J. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-28320-1 · Cited by 328
Low-intensity ultrasound neuromodulation: An overview of mechanisms and emerging human applications
Fomenko, A., Neudorfer, C., Dallapiazza, R. F., Kalia, S. K., & Lozano, A. M. (2018) · Brain Stimulation · doi:10.1016/j.brs.2018.08.013 · Cited by 322
Kubanek, J., Shukla, P., Das, A., Baccus, S. A., & Goodman, M. B. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1458-17.2018 · Cited by 305
Self-citationUltrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Ultrasound Produces Extensive Brain Activation via a Cochlear Pathway
Guo, H., Hamilton, M., Offutt, S. J., Gloeckner, C. D., Li, T., Kim, Y., Legon, W., Alford, J. K., & Lim, H. H. (2018) · Neuron · doi:10.1016/j.neuron.2018.04.036 · Cited by 291
Qiu, Z., Guo, J., Kala, S., Zhu, J., Xian, Q., Qiu, W., Li, G., Zhu, T., Meng, L., Zhang, R., et al. (2019) · iScience · doi:10.1016/j.isci.2019.10.037 · Cited by 266
Focused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation
Pashaei, V., Dehghanzadeh, P., Enwia, G., Bayat, M., Majerus, S. J. A., & Mandal, S. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2959439 · Cited by 79
The Emergence of Functional Ultrasound for Noninvasive Brain–Computer Interface
Zheng, H., Niu, L., Qiu, W., Liang, D., Long, X., Li, G., Liu, Z., & Meng, L. (2023) · Research · doi:10.34133/research.0200 · Cited by 27
Metadata
- Authors
- Kubanek, J., Shi, J., Marsh, J., Chen, D., Deng, C., & Cui, J.
- Venue
- Scientific Reports
- Published
- 2016-04-26
- Volume
- 6
- Issue
- 1
- Pages
- 24170-24170
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2342931385
- Cited by
- 353
- References
- 53
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.