CoChat

Non-invasive detection of animal nerve impulses with an atomic magnetometer operating near quantum limited sensitivity

Open access
Jensen, Kasper, Budvytyte, Rima, Thomas, Rodrigo A., Wang, Tian, Fuchs, Annette M., Balabas, Mikhail V., Vasilakis, Georgios, Mosgaard, Lars D., Stærkind, Hans C., Müller, Jörg H., Heimburg, Thomas, Olesen, Søren-Peter, Polzik, Eugene S. · 2016 · Scientific Reports

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Magnetic fields generated by human and animal organs, such as the heart, brain and nervous system carry information useful for biological and medical purposes. These magnetic fields are most commonly detected using cryogenically-cooled superconducting magnetometers. Here we present the first detection of action potentials from an animal nerve using an optical atomic magnetometer. Using an optimal design we are able to achieve the sensitivity dominated by the quantum shot noise of light and quantum projection noise of atomic spins. Such sensitivity allows us to measure the nerve impulse with a miniature room-temperature sensor which is a critical advantage for biomedical applications. Positioning the sensor at a distance of a few millimeters from the nerve, corresponding to the distance between the skin and nerves in biological studies, we detect the magnetic field generated by an action potential of a frog sciatic nerve. From the magnetic field measurements we determine the activity of the nerve and the temporal shape of the nerve impulse. This work opens new ways towards implementing optical magnetometers as practical devices for medical diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep29638

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (a) Schematic of the experimental setup. Probe light propagates along the z axis. Half-wave plate λ/2, polarizing beam splitter (PBS) and differential photodetection are components of polarization detector. (b) The magnetometer principle. The amplitude of the collective atomic spin precession in z, y plane is proportional to Bnerve. Spin projection Jz is measured by probe light with the sensitivity limited by the quantum projection spin noise (fuzzy circle). The magnetic field from the nerve is circumferal. The average field detected by the magnetometer points in the y-direction. (c) The measurement sequence for the pulsed magnetometer mode.
Figure 1 (a) Schematic of the experimental setup. Probe light propagates along the z axis. Half-wave plate λ/2, polarizing beam splitter (PBS) and differential photodetection are components of polarization detector. (b) The magnetometer principle. The amplitude of the collective atomic spin precession in z, y plane is proportional to Bnerve. Spin projection Jz is measured by probe light with the sensitivity limited by the quantum projection spin noise (fuzzy circle). The magnetic field from the nerve is circumferal. The average field detected by the magnetometer points in the y-direction. (c) The measurement sequence for the pulsed magnetometer mode.CC BY · PubMed Central
Figure 2 Electrical and optical measurements of the nerve impulse for different stimulation voltages. The optical measurements were done in the pulsed mode using 1000 averages. The figures show the signals in time, the square-root of the power spectral density PSD and the 400 Hz frequency component. The plotted electrical signals are after 10 times amplification. The uncertainties on the data points in (c) are to small to be visible in the figure. The uncertainties on the points in (f) can be estimated from the points without stimulation (0 V) which were measured 9 times and resulted in a 0.25(10) pT·ms signal. By dividing the nerve signal (9.1 pT·ms) by the noise floor obtained without stimulation (0.25 pT·ms) we find the signal to noise ratio, SNR ≈ 37.
Figure 2 Electrical and optical measurements of the nerve impulse for different stimulation voltages. The optical measurements were done in the pulsed mode using 1000 averages. The figures show the signals in time, the square-root of the power spectral density PSD and the 400 Hz frequency component. The plotted electrical signals are after 10 times amplification. The uncertainties on the data points in (c) are to small to be visible in the figure. The uncertainties on the points in (f) can be estimated from the points without stimulation (0 V) which were measured 9 times and resulted in a 0.25(10) pT·ms signal. By dividing the nerve signal (9.1 pT·ms) by the noise floor obtained without stimulation (0.25 pT·ms) we find the signal to noise ratio, SNR ≈ 37.CC BY · PubMed Central
Figure 3 Magnetic field fourier component as a function of distance (using 1000 averages per point). The closest distance from the center of the magnetometer to the center of the nerve was estimated to be 1.9 mm. Circles: Nerve magnetic field, squares: magnetometer noise floor, line: fit to a power-law dependence, fit parameters n = 1.5(4), x0 = 0.2(8) mm. The uncertainties on the fit parameters are the 68% confidence bounds.
Figure 3 Magnetic field fourier component as a function of distance (using 1000 averages per point). The closest distance from the center of the magnetometer to the center of the nerve was estimated to be 1.9 mm. Circles: Nerve magnetic field, squares: magnetometer noise floor, line: fit to a power-law dependence, fit parameters n = 1.5(4), x0 = 0.2(8) mm. The uncertainties on the fit parameters are the 68% confidence bounds.CC BY · PubMed Central
Figure 4 Electrical and optical measurements of the nerve impulse for different stimulation voltages. The magnetometer was operated in the continuous mode and the signals were averaged 5000 times. (a) Electrical and (b) optical measurements. (c) Electrical signal for 0.8 V stimulation and magnetic field calculated by deconvolution. For these specific measurements the Larmor frequency was 510 Hz and the coherence time 0.37 ms.
Figure 4 Electrical and optical measurements of the nerve impulse for different stimulation voltages. The magnetometer was operated in the continuous mode and the signals were averaged 5000 times. (a) Electrical and (b) optical measurements. (c) Electrical signal for 0.8 V stimulation and magnetic field calculated by deconvolution. For these specific measurements the Larmor frequency was 510 Hz and the coherence time 0.37 ms.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 83

Metadata

Authors
Jensen, K., Budvytyte, R., Thomas, R. A., Wang, T., Fuchs, A. M., Balabas, M. V., Vasilakis, G., Mosgaard, L. D., Stærkind, H. C., Müller, J. H., Heimburg, T., Olesen, S.-P., & Polzik, E. S.
Affiliations
University of Copenhagen (DK)
Corresponding author
Polzik, Eugene S.
Venue
Scientific Reports
Published
2016-07-15
Volume
6
Issue
1
Pages
29638-29638
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2239059663
Cited by
64
References
20
Citations by year
2026: 1 · 2025: 7 · 2024: 6 · 2023: 5 · 2022: 8 · 2021: 7 · 2020: 4 · 2019: 10 · 2018: 6 · 2017: 10
FWCI
4.10
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Repository@Nottingham (University of Nottingham) (publishedVersion, cc-by)
  • Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, other-oa)
  • arXiv (Cornell University) (submittedVersion)
  • Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
  • arXiv (Cornell University)
Funders
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Defense Advanced Research Projects Agency
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
Keywords
action potential, quantum shot noise, quantum projection noise, quantum-limited sensitivity, room-temperature magnetometry, frog sciatic nerve, non-invasive sensing, medical diagnostics
MeSH terms
Action Potentials, Animals, Anura, Magnetics, Sciatic Nerve, Quantum Dots

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.