Non-invasive detection of animal nerve impulses with an atomic magnetometer operating near quantum limited sensitivity
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Magnetic fields generated by human and animal organs, such as the heart, brain and nervous system carry information useful for biological and medical purposes. These magnetic fields are most commonly detected using cryogenically-cooled superconducting magnetometers. Here we present the first detection of action potentials from an animal nerve using an optical atomic magnetometer. Using an optimal design we are able to achieve the sensitivity dominated by the quantum shot noise of light and quantum projection noise of atomic spins. Such sensitivity allows us to measure the nerve impulse with a miniature room-temperature sensor which is a critical advantage for biomedical applications. Positioning the sensor at a distance of a few millimeters from the nerve, corresponding to the distance between the skin and nerves in biological studies, we detect the magnetic field generated by an action potential of a frog sciatic nerve. From the magnetic field measurements we determine the activity of the nerve and the temporal shape of the nerve impulse. This work opens new ways towards implementing optical magnetometers as practical devices for medical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“More generally, quantum technologies, such as quantum sensing, [243] might enhance the quality of imaging data of biomolecular structures (see e. g.Ref. [244]) and, therefore, improve the quality of the data on which further classical or quantum computations would be based.”
From Quantum Computing for Molecular Biology** (2023) · cites this paper as [244]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“For example, femtoTesla sensitivity has been achieved with magnetometers operating at a temperature of several hundred of ◦C in the so-called SERF regime [3] used also for medical applications [4–6].”
Optical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Quantum Noise Limited and Entanglement-Assisted Magnetometry
Wasilewski, W., Jensen, K., Krauter, H., Renema, J. J., Balabas, M. V., & Polzik, E. S. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.133601 · Cited by 434
Self-citationSubfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Magnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Magnetoencephalography: From SQUIDs to neuroscience
Hari, R., & Salmelin, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.074 · Cited by 285
Polarized Alkali-Metal Vapor with Minute-Long Transverse Spin-Relaxation Time
Balabas, M. V., Karaulanov, T., Ledbetter, M. P., & Budker, D. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.070801 · Cited by 272
Self-citation
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
Optimal and secure measurement protocols for quantum sensor networks
Eldredge, Z., Foss-Feig, M., Gross, J. A., Rolston, S. L., & Gorshkov, A. V. (2018) · Physical Review A · doi:10.1103/physreva.97.042337 · Cited by 170
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
Optimal Control for One-Qubit Quantum Sensing
Poggiali, F., Cappellaro, P., & Fabbri, N. (2018) · Physical Review X · doi:10.1103/physrevx.8.021059 · Cited by 117
Miniature cavity-enhanced diamond magnetometer
Chatzidrosos, G., Wickenbrock, A., Bougas, L., Leefer, N., Wu, T., Jensen, K., Dumeige, Y., & Budker, D. (2017) · Physical Review Applied · doi:10.1103/physrevapplied.8.044019 · Cited by 103
Self-citationSimultaneous tracking of spin angle and amplitude beyond classical limits
Colangelo, G., Ciurana, F. M., Bianchet, L. C., Sewell, R. J., & Mitchell, M. W. (2017) · Nature · doi:10.1038/nature21434 · Cited by 94
Quantum Computing for Molecular Biology**
Baiardi, A., Christandl, M., & Reiher, M. (2023) · ChemBioChem · doi:10.1002/cbic.202300120 · Cited by 93
Improving cold-atom sensors with quantum entanglement: Prospects and challenges
Szigeti, S. S., Hosten, O., & Haine, S. A. (2021) · Applied Physics Letters · doi:10.1063/5.0050235 · Cited by 90
Heisenberg-scaling measurement protocol for analytic functions with quantum sensor networks
Qian, K., Eldredge, Z., Ge, W., Pagano, G., Monroe, C. R., Porto, J. V., & Gorshkov, A. V. (2019) · Physical Review A · doi:10.1103/physreva.100.042304 · Cited by 86
Webb, J. L., Troise, L., Hansen, N. W., Olsson, C., Wojciechowski, A. M., Achard, J., Brinza, O., Staacke, R., Kieschnick, M., Meijer, J., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-81828-x · Cited by 84
Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-34535-z · Cited by 79
Self-citationFemtotesla Direct Magnetic Gradiometer Using a Single Multipass Cell
Lucivero, V. G., Lee, W., Dural, N., & Romalis, M. V. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.014004 · Cited by 77
Nanoscale Vector dc Magnetometry via Ancilla-Assisted Frequency Up-Conversion
Liu, Y.-X., Ajoy, A., & Cappellaro, P. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.100501 · Cited by 71
Action potentials induce biomagnetic fields in carnivorous Venus flytrap plants
Fabricant, A. M., Iwata, G. Z., Scherzer, S. H., Bougas, L., Rolfs, K., Jodko-Władzińska, A., Voigt, J., Hedrich, R., & Budker, D. (2021) · Scientific Reports · doi:10.1038/s41598-021-81114-w · Cited by 65
High-sensitivity magnetometry with a single atom in a superposition of two circular Rydberg states
Dietsche, E.-K., Larrouy, A., Haroche, S., Raimond, J. M., Brune, M., & Gleyzes, S. (2019) · Nature Physics · doi:10.1038/s41567-018-0405-4 · Cited by 60
Femtotesla Nearly-Quantum-Noise-Limited Pulsed Gradiometer at Earth-Scale Fields
Lucivero, V. G., Lee, W., Limes, M. E., Foley, E. L., Kornack, T. W., & Romalis, M. V. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.l021001 · Cited by 60
Ultralow-Noise Room-Temperature Quantum Memory for Polarization Qubits
Namazi, M., Kupchak, C., Jordaan, B., Shahrokhshahi, R., & Figueroa, E. V. (2017) · Physical Review Applied · doi:10.1103/physrevapplied.8.034023 · Cited by 55
Characterization of high-temperature performance of cesium vapor cells with anti-relaxation coating
Li, W., Balabas, M. V., Peng, X., Pustelny, S., Wickenbrock, A., Guo, H. M., & Budker, D. (2017) · Journal of Applied Physics · doi:10.1063/1.4976017 · Cited by 49
Self-citationIntegrable quantum many-body sensors for AC field sensing
Mishra, U., & Bayat, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-17381-y · Cited by 44
Nishi, K., Ito, Y., & Kobayashi, T. (2018) · Optics Express · doi:10.1364/oe.26.001988 · Cited by 43
Detection of low-conductivity objects using eddy current measurements with an optical magnetometer
Jensen, K., Zugenmaier, M., Arnbak, J., Stærkind, H., Balabas, M. V., & Polzik, E. S. (2019) · Physical Review Research · doi:10.1103/physrevresearch.1.033087 · Cited by 40
Self-citationTriboelectric Nanogenerators as Power Sources for Chemical Sensors and Biosensors
Khandelwal, G., Deswal, S., & Dahiya, R. (2022) · ACS Omega · doi:10.1021/acsomega.2c06335 · Cited by 39
Mauranyapin, N. P., Terrasson, A., & Bowen, W. P. (2022) · Advanced Quantum Technologies · doi:10.1002/qute.202100139 · Cited by 37
Entanglement-Enhanced Radio-Frequency Field Detection and Waveform Sensing
Ciurana, F. M., Colangelo, G., Slodička, L., Sewell, R. J., & Mitchell, M. W. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.043603 · Cited by 36
Recording the heart beat of cattle using a gradiometer system of optically pumped magnetometers
Sutter, J. U., Lewis, O., Robinson, C., McMahon, A., Boyce, R., Bragg, R., Macrae, A., Orton, J., Shah, V., Ingleby, S. J., et al. (2020) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2020.105651 · Cited by 35
Shukla, R. K., Chotorlishvili, L., Mishra, S. K., & Iemini, F. (2025) · Physical review. B./Physical review. B · doi:10.1103/physrevb.111.024315 · Cited by 32
Voigt-effect-based three-dimensional vector magnetometer
Pyragius, T., Florez, H. M., & Fernholz, T. (2019) · Physical Review A · doi:10.1103/physreva.100.023416 · Cited by 30
Imaging Magnetic Nanoparticle Distributions by Atomic Magnetometry-Based Susceptometry
Colombo, S., Lebedev, V., Tonyushkin, A., Pengue, S., & Weis, A. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2937670 · Cited by 26
Optimising the sensing volume of OPM sensors for MEG source reconstruction
Bezsudnova, Y., Koponen, L. M., Barontini, G., Jensen, O. B., & Kowalczyk, A. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119747 · Cited by 24
Magnetic microscopic imaging with an optically pumped magnetometer and flux guides
Kim, Y. J., Savukov, I., Huang, J., & Nath, P. (2017) · Applied Physics Letters · doi:10.1063/1.4975069 · Cited by 22
Effects of pressure on suspended micromechanical membrane arrays
Naesby, A., Naserbakht, S., & Dantan, A. (2017) · Applied Physics Letters · doi:10.1063/1.5004261 · Cited by 20
Wu, L., Shang, J., Ji, Y., Gan, Q., & Wong, C. (2017) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2017.2773509 · Cited by 19
Extending dephasing time of nitrogen-vacancy center in diamond by suppressing nuclear spin noise
Chen, X., Qiu, C.-D., Lu, Y.-N., Liu, G., Ruan, D., Zhang, F., & Long, G. (2023) · Physical review. B./Physical review. B · doi:10.1103/physrevb.108.174111 · Cited by 17
Modelling of Cavity Optomechanical Magnetometers
Yu, Y., Forstner, S., Rubinsztein-Dunlop, H. H., & Bowen, W. P. (2018) · Sensors · doi:10.3390/s18051558 · Cited by 17
Reconstruction-Free Quantum Sensing of Arbitrary Waveforms
Zopes, J., & Degen, C. L. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.054028 · Cited by 15
Mixed-signal data acquisition system for optically detected magnetic resonance of solid-state spins
Zhou, F., Song, S., Deng, Y., Zhang, T., Chen, B., & Xu, N. (2021) · Review of Scientific Instruments · doi:10.1063/5.0070135 · Cited by 12
Magnetic-field-independent spin-exchange relaxation-free magnetometer
Dikopoltsev, M., Levy, U., & Katz, O. (2025) · Physical Review A · doi:10.1103/physreva.111.032602 · Cited by 9
Bi‐Frequency Illumination: A Quantum‐Enhanced Protocol
Casariego, M., Omar, Y., & Sanz, M. (2022) · Advanced Quantum Technologies · doi:10.1002/qute.202100051 · Cited by 9
A three-dimensional scanning trapped-ion probe
Sägesser, T., Jain, S., Hrmo, P., Ferk, A., Simoni, M., Cui, Y., Mordini, C., Kienzler, D., & Home, J. (2026) · Science Advances · doi:10.1126/sciadv.aec0794 · Cited by 8
Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure
Wu, Z., Zhang, J., Chen, W., Ou, Z., Yue, H., Cheng, C., & Liu, Y. (2024) · Optics Letters · doi:10.1364/ol.518697 · Cited by 8
Magnetic induction sensor based on a dual-frequency atomic magnetometer
Wang, H., Zugenmaier, M., Jensen, K., Zheng, W., & Polzik, E. S. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.034030 · Cited by 7
Self-citationOptically Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_49 · Cited by 7
Chun-wang, L., Liu, Y., Du, L., Su, W.-J., Wu, H., & Li, Y. (2023) · Optics Express · doi:10.1364/oe.482075 · Cited by 7
Quantum sensing with Rydberg Schrödinger cat states
Dietsche, E.-K. (2017) · theses.fr (ABES) · doi:10.70675/98847d49ze424z48c2zaf00z5b360127db6f · Cited by 7
Floquet description of optically pumped magnetometers
Florez, H. M., & Pyragius, T. (2021) · Physical Review A · doi:10.1103/physreva.103.033113 · Cited by 6
Magnetic-field gradiometer based on ultracold collisions
Wasak, T., Jachymski, K., Calarco, T., & Negretti, A. (2018) · Physical Review A · doi:10.1103/physreva.97.052701 · Cited by 6
Quantum vector DC magnetometry via selective phase accumulation
Zhuang, M., Chen, S., Huang, J., & Lee, C. (2024) · Science China Physics Mechanics and Astronomy · doi:10.1007/s11433-024-2400-1 · Cited by 5
Small Animal Biomagnetism Applications
Jensen, K., Bentzen, B. H., & Polzik, E. S. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_3 · Cited by 5
Self-citationA review of advances in next-generation materials for quantum sensing and communication
Meziani, K., Oukaira, A., Mouaci, S., Aghanim, A., Guermal, M., Aziz, N. E., & Esshaimi, Y. (2025) · Materials Research Express · doi:10.1088/2053-1591/ae2f26 · Cited by 4
Quantum Sensing of Magnetic Fields Using Global Optimization Algorithms
Xiao, W., Ding, Y., Wu, T., Peng, X., & Guo, H. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024042 · Cited by 4
Quantum Sensing of Fast Time-Varying Magnetic Field With Daubechies Wavelets
Kiang, C.-W., Ding, J., & Kiang, J. (2024) · IEEE Access · doi:10.1109/access.2024.3364817 · Cited by 4
Magnetoresistance-based Biosensors
Sharma, A., Chougale, A. D., Salvan, G., & Patil, P. B. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781839162756-00369 · Cited by 3
Spectrum demodulating polarimeter based on weak measurement with a phase modulation
Li, D., He, Y., Ruan, Y., Lin, Q., & Li, K. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab3974 · Cited by 3
Shadehi, L. F., Jahromi, H. R., & Ghanaatian, M. (2020) · International Journal of Quantum Information · doi:10.1142/s0219749920400018 · Cited by 3
Optically Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_49-1 · Cited by 3
Synchronized time tagger for single-photon detection in one- and two-dimension quantum experiments
Ye, R., Lin, X., Zhou, F., Dai, Y., Hu, Q., Li, X., Xie, G., & Xu, N. (2022) · Review of Scientific Instruments · doi:10.1063/5.0086943 · Cited by 3
Local magnetic detection and stimulation of neuronal activity
Trauchessec, V. (2017) · theses.fr (ABES) · doi:10.70675/e7a598c8z9179z4158zb82bzd45c82c88afe · Cited by 3
Phase-modulated dynamical decoupling sequences robust to systematic amplitude error
陈, S. 思. C., Chen, G., 黄, J. 嘉. H., Liu, P., Zhuang, M., & Lee, C. (2025) · Chinese Physics B · doi:10.1088/1674-1056/adcd43 · Cited by 2
High-resolution magnetic imaging with an array of flux guides
Savukov, I., & Kim, Y. J. (2017) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2017.7894048 · Cited by 2
Calibration of spin-light coupling by coherently induced Faraday rotation
Thomas, R. A., Østfeldt, C., Bærentsen, C., Parniak, M. P., & Polzik, E. S. (2021) · Optics Express · doi:10.1364/oe.425613 · Cited by 2
Self-citationSingle nitrogen-vacancy centers in diamond for spin quantum control
Poggiali, F. (2019) · Florence Research (University of Florence) · Cited by 2
Action potentials induce biomagnetic fields in Venus flytrap plantsPreprint
Fabricant, A. M., Iwata, G. Z., Scherzer, S. H., Bougas, L., Rolfs, K., Jodko-Władzińska, A., Voigt, J., Hedrich, R., & Budker, D. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.08.12.247924 · Cited by 2
Intrinsic Pulsed Magnetic Gradiometer in Earth's FieldPreprint
Campbell, K., Wang, Y.-J., Savukov, I., Schwindt, P. D. D., Jau, Y., & Shah, V. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2111.12310 · Cited by 2
Frequency Range Boosted Magnetometry Beyond the Spin Coherence Limit via Compressive SensingPreprint
Wang, R., Yang, P., Huang, D., Bao, G., & Zhang, W. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2505.05825 · Cited by 2
Radio-Frequency Optically Pumped Magnetometers for Eddy Current Measurements
Rushton, L. M. (2023) · Nottingham ePrints (University of Nottingham) · Cited by 2
Compressive quantum waveform estimation
Tritt, A., Morris, J., Bounds, C. C., Taylor, H. A. M., Saunderson, J., & Turner, L. D. (2025) · Physical Review A · doi:10.1103/physreva.111.022625 · Cited by 1
Wearable resistive graphene-based sensor for human behavioral and mental monitoring
Antonova, I. V., Ivanov, A. I., Buzmakova, A. A., Черкасова, О. П., Shavelkina, M. B., & Nebogatikova, N. A. (2025) · Journal of Materials Chemistry C · doi:10.1039/d5tc00128e · Cited by 1
Enhanced magnetic field sensing using geometric-mediated whispering gallery mode resonators
Ali, A., Yousry, Y., & Anssary, A. E. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117458 · Cited by 1
Generation and Uses of Distributed Entanglement in Quantum Information
Eldredge, Z. (2019) · University Libraries (University of Maryland) · doi:10.13016/6b1j-tsik · Cited by 1
Coherent sensing of magnetic waveforms with spin-squeezed atoms
Ciurana, F. M. (2017) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-114448
LABEL FREE OPTICAL DETECTION OF ELECTRICAL ACTIVITY IN MAMMALIAN NEURONS
Satpathy, S. (2018) · UTA ResearchCommons (University of Texas Arlington)
Sensing and Communication with Quantum MicrowavesPreprint
Casariego, M. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2310.04838
Biomagnetic sensors based on spin electronics
Chopin, C. (2020) · theses.fr (ABES) · doi:10.70675/a2fc127fzdcfcz4b14z8c67z37ed5d0052ca
Thermomagnetic instability in superconducting lead-porous glass nanocomposites
Shitov, A. E., Mikhailin, N. Y., Kumzerov, Y. A., & Shamshur, D. V. (2024) · Physica C Superconductivity · doi:10.1016/j.physc.2024.1354502
Stroboscopic microwave spectroscopy of Voigt-based optically pumped magnetometers
Florez, H. M., Pyragius, T., & Fernholz, T. (2024) · Physical Review A · doi:10.1103/physreva.110.043102
Quantum coherence control for radio-frequency dressed cold atom systems
Foxon, B. (2021) · Nottingham ePrints (University of Nottingham)
Achieving Submillimeter Spatial Resolution and Signal Enhancement in SERF Atomic Magnetometers
Wu, Y., Yan, Y., Sun, B., Ding, X., Zhou, C., Zhou, Y., & Lu, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3632439
Heimburg, T. (2025) · Wiley eBooks · doi:10.1002/9783527690596.refs
Self-citationKowalczyk, A., Bezsudnova, Y., Barontini, G., & Jensen, O. B. (2026) · University of Birmingham Research Portal (University of Birmingham) · doi:10.25500/edata.bham.00001639
Nanoparticle-Mediated Nose-to-Brain Drug Delivery Systems: A Promising Approach for CNS Therapeutics
Singh, S., & Trilochana, N. (2026) · International Journal of Pharmaceutical and Healthcare Innovation. · doi:10.62752/ijphi.v3i2.250
Plasma-Enabled Phase Control of Electromagnetically Induced Transparency in Terahertz Metasurfaces
Varikuntla, K. K., Abbasi, M. A. B., & Yurduseven, O. (2026) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/ap-s/usnc-ursi60190.2026.11675509
Electromagnetically Induced Transparency Using Dispersive Plasma Media
Varikuntla, K. K., Abbasi, M. A. B., & Yurduseven, O. (2026) · European Conference on Antennas and Propagation · doi:10.23919/eucap68105.2026.11612277
Metadata
- Authors
- Jensen, K., Budvytyte, R., Thomas, R. A., Wang, T., Fuchs, A. M., Balabas, M. V., Vasilakis, G., Mosgaard, L. D., Stærkind, H. C., Müller, J. H., Heimburg, T., Olesen, S.-P., & Polzik, E. S.
- Affiliations
- University of Copenhagen (DK)
- Corresponding author
- Polzik, Eugene S.
- Venue
- Scientific Reports
- Published
- 2016-07-15
- Volume
- 6
- Issue
- 1
- Pages
- 29638-29638
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC4945862
- OpenAlex
- W2239059663
- Cited by
- 64
- References
- 20
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 6 · 2023: 5 · 2022: 8 · 2021: 7 · 2020: 4 · 2019: 10 · 2018: 6 · 2017: 10
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion, cc-by)
- Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, other-oa)
- arXiv (Cornell University) (submittedVersion)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Defense Advanced Research Projects Agency
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- action potential, quantum shot noise, quantum projection noise, quantum-limited sensitivity, room-temperature magnetometry, frog sciatic nerve, non-invasive sensing, medical diagnostics
- MeSH terms
- Action Potentials, Animals, Anura, Magnetics, Sciatic Nerve, Quantum Dots
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.