The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing
Open accessAbstract
Neural sensing and stimulation have been the backbone of neuroscience research, brain-machine interfaces and clinical neuromodulation therapies for decades. To-date, most of the neural stimulation systems have relied on sharp metal microelectrodes with poor electrochemical properties that induce extensive damage to the tissue and significantly degrade the long-term stability of implantable systems. Here, we demonstrate a flexible cortical microelectrode array based on porous graphene, which is capable of efficient electrophysiological sensing and stimulation from the brain surface, without penetrating into the tissue. Porous graphene electrodes show superior impedance and charge injection characteristics making them ideal for high efficiency cortical sensing and stimulation. They exhibit no physical delamination or degradation even after 1 million biphasic stimulation cycles, confirming high endurance. In in vivo experiments with rodents, same array is used to sense brain activity patterns with high spatio-temporal resolution and to control leg muscles with high-precision electrical stimulation from the cortical surface. Flexible porous graphene array offers a minimally invasive but high efficiency neuromodulation scheme with potential applications in cortical mapping, brain-computer interfaces, treatment of neurological disorders, where high resolution and simultaneous recording and stimulation of neural activity are crucial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is penetrating microelectrodes with low-charge/phase thresholds, high-charge density thresholds and smaller surface area, which are more suitable for stimulating specific functional areas in a selective and high spatial resolution way.[543,544]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [543]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of the Elastic Properties and Intrinsic Strength of Monolayer Graphene
Lee, C., Wei, X., Kysar, J. W., & Hone, J. (2008) · Science · doi:10.1126/science.1157996 · Cited by 20,847
Superior Thermal Conductivity of Single-Layer Graphene
Balandin, A. A., Ghosh, S., Bao, W., Calizo, I., Teweldebrhan, D., Miao, F., & Lau, C. N. (2008) · Nano Letters · doi:10.1021/nl0731872 · Cited by 13,823
Graphene photonics and optoelectronics
Bonaccorso, F., Sun, Z., Hasan, T., & Ferrari, A. C. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.186 · Cited by 7,726
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Laser-induced porous graphene films from commercial polymers
Lin, J., Peng, Z., Liu, Y., Ruiz-Zepeda, F., Ye, R., Samuel, E. L. G., Yacaman, M. J., Yakobson, B. I., & Tour, J. M. (2014) · Nature Communications · doi:10.1038/ncomms6714 · Cited by 2,946
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Liu, H., Liu, Y., & Zhu, D. (2011) · J. Mater. Chem. · doi:10.1039/c0jm02922j · Cited by 1,629
(2001) · New England Journal of Medicine · doi:10.1056/nejmoa000827 · Cited by 1,514
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Research works printed but not linked: 1
- Peng, Z., Lin, J., Ye, R., Samuel, E. & Tour, J. Flexible and Stackable Laser-Induced Graphene Supercapacitors. ACS Appl. Mater. Interfaces 7, 3414–3419 (2015). · DOI · Paper page
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Two-Dimensional Ti3C2 MXene for High-Resolution Neural Interfaces
Driscoll, N., Richardson, A. G., Maleski, K., Anasori, B., Adewole, O., Lelyukh, P., Escobedo, L., Cullen, D. K., Lucas, T. H., Gogotsi, Y., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b06014 · Cited by 312
Self-citationEmerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 239
Next-generation interfaces for studying neural function
Frank, J. A., Antonini, M.-J., & Anikeeva, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0198-8 · Cited by 241
Metadata
- Authors
- Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D.
- Affiliations
- University of California San Diego (US)
- University of Pennsylvania (US)
- Venue
- Scientific Reports
- Published
- 2016-09-19
- Volume
- 6
- Issue
- 1
- Pages
- 33526-33526
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5027596
- OpenAlex
- W2521706094
- Cited by
- 213
- References
- 47
- Citations by year
- 2026: 13 · 2025: 19 · 2024: 19 · 2023: 23 · 2022: 22 · 2021: 44 · 2020: 23 · 2019: 17 · 2018: 20 · 2017: 12
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- University of California, San Diego
- Office of Naval Research
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- porous graphene, neural sensing, brain-computer interface, neuromodulation, charge injection, electrode impedance, cortical mapping
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing. https://app.cochat.ai/papers/10.1038/srep33526
- The paper
- Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D. (2016). Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing. Scientific Reports. https://doi.org/10.1038/srep33526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.