The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Gesture recognition by instantaneous surface EMG images
Open accessAbstract
Gesture recognition in non-intrusive muscle-computer interfaces is usually based on windowed descriptive and discriminatory surface electromyography (sEMG) features because the recorded amplitude of a myoelectric signal may rapidly fluctuate between voltages above and below zero. Here, we present that the patterns inside the instantaneous values of high-density sEMG enables gesture recognition to be performed merely with sEMG signals at a specific instant. We introduce the concept of an sEMG image spatially composed from high-density sEMG and verify our findings from a computational perspective with experiments on gesture recognition based on sEMG images with a classification scheme of a deep convolutional network. Without any windowed features, the resultant recognition accuracy of an 8-gesture within-subject test reached 89.3% on a single frame of sEMG image and reached 99.0% using simple majority voting over 40 frames with a 1,000 Hz sampling rate. Experiments on the recognition of 52 gestures of NinaPro database and 27 gestures of CSL-HDEMG database also validated that our approach outperforms state-of-the-arts methods. Our findings are a starting point for the development of more fluid and natural muscle-computer interfaces with very little observational latency. For example, active prostheses and exoskeletons based on high-density electrodes could be controlled with instantaneous responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Scikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016
Matplotlib: a 2D graphics environment
Hunter, J. D. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.55 · Cited by 39,249
(2014) · Cited by 33,419
Reducing the dimensionality of data with neural networks
Hinton, G. E., & Salakhutdinov, R. R. (2006) · Science · doi:10.1126/science.1127647 · Cited by 20,928
Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification
He, K., Zhang, X., Ren, S., & Sun, J. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.123 · Cited by 19,741
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S. (2024) · arXiv (Cornell University) · doi:10.57702/o9raffed · Cited by 14,214
Learning Deep Architectures for AI
Bengio, Y. (2009) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000006 · Cited by 6,938
DeepFace: Closing the Gap to Human-Level Performance in Face Verification
Taigman, Y., Yang, M., Ranzato, M., & Wolf, L. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.220 · Cited by 6,542
Learning Deep Architectures for AI
Bengio, Y. (2009) · now publishers, Inc. eBooks · doi:10.1561/9781601982957 · Cited by 4,941
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
(2013) · Cited by 3,740
OverFeat: Integrated Recognition, Localization and Detection using Convolutional Networks
Sermanet, P., Eigen, D., Zhang, X., Mathieu, M., Fergus, R., & LeCun, Y. (2013) · arXiv · doi:10.48550/arxiv.1312.6229 · Cited by 2,680
MXNet: A Flexible and Efficient Machine Learning Library for Heterogeneous Distributed Systems
Chen, T., Li, M., Li, Y., Lin, M., Wang, N., Wang, M., Xiao, T., Xu, B., Zhang, C., & Zhang, Z. (2015) · arXiv · doi:10.48550/arxiv.1512.01274 · Cited by 1,819
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
Smith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2100828 · Cited by 443
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
Farina, D., & Merletti, R. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00025-0 · Cited by 367
Johnson, A. N., Huo, X., Ghovanloo, M., & Shinohara, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-1 · Cited by 321
Jiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Lu, Z., Chen, X., Li, Q., Zhang, X., & Zhou, P. (2014) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2014.2302794 · Cited by 294
Hargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276
Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357138 · Cited by 275
Stango, A., Negro, F., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2366752 · Cited by 191
High-density surface EMG maps from upper-arm and forearm muscles
Rojas-Martínez, M., Mañanas, M. A., & Alonso, J. F. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-85 · Cited by 181
Myoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
High-Density Myoelectric Pattern Recognition Toward Improved Stroke Rehabilitation
Zhang, X., & Zhou, P. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2191551 · Cited by 170
Advancing Muscle-Computer Interfaces with High-Density Electromyography
Amma, C., Krings, T., Böer, J., & Schultz, T. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702501 · Cited by 168
Making muscle-computer interfaces more practical
Saponas, T. S., Tan, D. S., Morris, D., Turner, J., & Landay, J. A. (2010) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1753326.1753451 · Cited by 141
Kleine, B.-U., Schumann, N.-P., Stegeman, D. F., & Scholle, H. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00306-5 · Cited by 119
EMG-Based Continuous Control Scheme With Simple Classifier for Electric-Powered Wheelchair
Jang, G., Kim, J., Lee, S., & Choi, Y. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2522385 · Cited by 95
Intimate interfaces in action: assessing the usability and subtlety of emg-based motionless gestures
Costanza, E., Inverso, S. A., Allen, R., & Maes, P. (2007) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1240624.1240747 · Cited by 92
Identification of isometric contractions based on High Density EMG maps
Rojas-Martínez, M., Mañanas, M. Á., Alonso, J. F., & Merletti, R. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.06.009 · Cited by 80
Outlier detection in high-density surface electromyographic signals
Marateb, H. R., Rojas-Martínez, M., Mansourian, M., Merletti, R., & Mañanas, M. Á. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0790-7 · Cited by 61
Multi-source Adaptive Learning for Fast Control of Prosthetics Hand
Patricia, N., Tommasit, T., & Barbara Caputo, B. (2014) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2014.477 · Cited by 39
Surface Electromyography signal processing and application: a review
Norali, A. N., & Hanafi, M. S. M. (2009) · Cited by 36
Fatigue and fibromyalgia syndrome: Clinical and neurophysiologic pattern
Casale, R., & Rainoldi, A. (2011) · Best Practice & Research Clinical Rheumatology · doi:10.1016/j.berh.2011.01.016 · Cited by 32
Cited by
Deep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition
Moin, A., Zhou, A., Rahimi, A., Menon, A., Benatti, S., Alexandrov, G., Tamakloe, S., Ting, J., Yamamoto, N., Khan, Y., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-00510-8 · Cited by 680
Ultra-sensitive and resilient compliant strain gauges for soft machines
Araromi, O. A., Graule, M. A., Dorsey, K. L., Castellanos, S., Foster, J. R., Hsu, W.-H., Passy, A. E., Vlassak, J. J., Weaver, J. C., Walsh, C. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2892-6 · Cited by 511
A novel attention-based hybrid CNN-RNN architecture for sEMG-based gesture recognition
Hu, Y., Wong, Y., Wei, W., Du, Y., Kankanhalli, M., & Geng, W. (2018) · PLOS ONE · doi:10.1371/journal.pone.0206049 · Cited by 398
Self-citation
Metadata
- Authors
- Geng, W., Du, Y., Jin, W., Wei, W., Hu, Y., & Li, J.
- Venue
- Scientific Reports
- Published
- 2016-11-15
- Volume
- 6
- Issue
- 1
- Pages
- 36571-36571
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2555541061
- Cited by
- 595
- References
- 44
- FWCI
- 16.72
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.