The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Transport and reaction in microscale segmented gas–liquid flow
Abstract
We use micro particle image velocimetry (microPIV) and fluorescence microscopy techniques to characterize microscale segmented gas-liquid flow at low superficial velocities relevant for chemical reactions with residence times of up to several minutes. Different gas-liquid microfluidic channel networks of rectangular cross section are fabricated in poly(dimethylsiloxane) (PDMS) using soft lithography techniques. The recirculation motion in the liquid segments associated with gas-liquid flows as well as the symmetry characteristics of the recirculations are quantified for straight and meandering channel networks. Even minor surface roughness effects and the compressibility of the gas phase induce loss of symmetry and enhance mixing across the centerline in straight channels. Mixing is further accelerated in meandering channels by the periodic switching of recirculation patterns across the channel center. We demonstrate a new, piezoelectrically activated flow injection technique for determining residence time distributions (RTDs) of fluid elements in multiphase microfluidic systems. The results confirm a narrowed liquid phase RTD in segmented flows in comparison to their single-phase counterparts. The enhanced mixing and narrow RTD characteristics of segmented gas-liquid flows are applied to liquid mixing and in sol-gel synthesis of colloidal nanoparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled growth of monodisperse silica spheres in the micron size range
Stöber, W., Fink, A., & Bohn, E. (1968) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(68)90272-5 · Cited by 14,532
Levenspiel, O. (1999) · Industrial & Engineering Chemistry Research · doi:10.1021/ie990488g · Cited by 9,970
Dispersion of soluble matter in solvent flowing slowly through a tube
Taylor, G. I. (1953) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1953.0139 · Cited by 5,109
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Chemistry in Microstructured Reactors
Jähnisch, K., Hessel, V., Löwe, H., & Baerns, M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300577 · Cited by 1,286
MICRO-ELECTRO-MECHANICAL-SYSTEMS (MEMS) AND FLUID FLOWS
Ho, C.-M., & Tai, Y.-C. (1998) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.30.1.579 · Cited by 1,254
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Microreaction engineering — is small better?
Jensen, K. F. (2001) · Chemical Engineering Science · doi:10.1016/s0009-2509(00)00230-x · Cited by 1,124
Self-citationA Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
PIV measurements of a microchannel flow
Meinhart, C. D., Wereley, S. T., & Santiago, J. G. (1999) · Experiments in Fluids · doi:10.1007/s003480050366 · Cited by 802
Surface-Directed Liquid Flow Inside Microchannels
Zhao, B., Moore, J. S., & Beebe, D. J. (2001) · Science · doi:10.1126/science.291.5506.1023 · Cited by 765
Tice, J. D., Song, H., Lyon, A. D., & Ismagilov, R. F. (2003) · Langmuir · doi:10.1021/la030090w · Cited by 722
Notes on the diffusion-type model for the longitudinal mixing of fluids in flow
Levenspiel, O., & Smith, W. K. (1957) · Chemical Engineering Science · doi:10.1016/0009-2509(57)85021-0 · Cited by 579
Hills, J. (1992) · Chemical Engineering Science · doi:10.1016/0009-2509(92)85172-8 · Cited by 533
The intensification of rapid reactions in multiphase systems using slug flow in capillaries
Burns, J. R., & Ramshaw, C. (2001) · Lab on a Chip · doi:10.1039/b102818a · Cited by 503
Deckwer, W., Cottrell, V., & Field, R. W. (1991) · Medical Entomology and Zoology · Cited by 499
Efficient detection of spurious vectors in particle image velocimetry data
Westerweel, J. (1994) · Experiments in Fluids · doi:10.1007/bf00206543 · Cited by 486
Microfabricated Multiphase Packed-Bed Reactors: Characterization of Mass Transfer and Reactions
Losey, M. W., Schmidt, M. A., & Jensen, K. F. (2001) · Industrial & Engineering Chemistry Research · doi:10.1021/ie000523f · Cited by 446
Self-citationMultiphase catalytic reactors: a perspective on current knowledge and future trends
Duduković, M. P., Larachi, F., & Mills, P. L. (2002) · Catalysis Reviews · doi:10.1081/cr-120001460 · Cited by 362
Multiphase reactors – revisited
Dudukovic, M. P., Larachi, F., & Mills, P. L. (1999) · Chemical Engineering Science · doi:10.1016/s0009-2509(98)00367-4 · Cited by 331
Noninvasive Tomographic and Velocimetric Monitoring of Multiphase Flows
Chaouki, J., Larachi, F., & Duduković, M. P. (1997) · Industrial & Engineering Chemistry Research · doi:10.1021/ie970210t · Cited by 294
Design and fabrication of microfluidic devices for multiphase mixing and reaction
Losey, M. W., Jackman, R. J., Firebaugh, S. L., Schmidt, M. A., & Jensen, K. F. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.803416 · Cited by 232
Self-citationMicrofabricated Multiphase Reactors for the Selective Direct Fluorination of Aromatics
de Mas, N., Günther, A., Schmidt, M. A., & Jensen, K. F. (2003) · Industrial & Engineering Chemistry Research · doi:10.1021/ie020717q · Cited by 185
Self-citation
Cited by
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Metadata
- Authors
- Günther, A., Khan, S. A., Thalmann, M., Trachsel, F., & Jensen, K. F.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 4
- Issue
- 4
- Pages
- 278-286
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1894736934
- Cited by
- 534
- References
- 25
- FWCI
- 17.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.