The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-sensitivity miniaturized immunoassays for tumor necrosis factor ? using microfluidic systems
Abstract
We use microfluidic chips to detect the biologically important cytokine tumor necrosis factor alpha (TNF- alpha) with picomolar sensitivity using sub-microliter volumes of samples and reagents. The chips comprise a number of independent capillary systems (CSs), each of which is composed of a filling port, an appended microchannel, and a capillary pump. Each CS fills spontaneously by capillary forces and includes a self-regulating mechanism that prevents adventitious drainage of the microchannels. Thus, interactive control of the flow in each CS is easily achieved via collective control of the evaporation in all CSs by means of two Peltier elements that can independently heat and cool. Long incubation times are crucial for high sensitivity assays and can be conveniently obtained by adjusting the evaporation rate to have low flow rates of approximately 30 nL min(-1). The assay is a sandwich fluorescence immunoassay and takes place on the surface of a poly(dimethylsiloxane)(PDMS) slab placed across the microchannels. We precoat PDMS with capture antibodies (Abs), localize the capture of analyte molecules using a chip, then bind the captured analyte molecules with fluorescently-tagged detection Abs using a second chip. The assay results in a mosaic of fluorescence signals on the PDMS surface which are measured using a fluorescence scanner. We show that PDMS is a compatible material for high sensitivity fluorescence assays, provided that detection antibodies with long excitation wavelength fluorophores ( > or =580 nm) are employed. The chip design, long incubation times, proper choice of fluorophores, and optimization of the detection Ab concentration all combine to achieve high-sensitivity assays. This is exemplified by an experiment with 170 assay sites, occupying an area of approximately 0.6 mm(2) on PDMS to detect TNF-alpha in 600 nL of a dendritic cell (DC) culture medium with a sensitivity of approximately 20 pg mL(-1)(1.14 pM).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sallusto, F., & Lanzavecchia, A. (1994) · The Journal of Experimental Medicine · doi:10.1084/jem.179.4.1109 · Cited by 5,129
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Self-citationMicrofluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Kim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D. (2018) · Lab on a Chip · doi:10.1039/c8lc00458g · Cited by 451
Self-citationDu, D., Zou, Z., Shin, Y., Wang, J., Wu, H., Engelhard, M. H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac100036p · Cited by 448
Microfluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398
Capillary pumps for autonomous capillary systems
Zimmermann, M., Schmid, H., Hunziker, P., & Delamarche, E. (2007) · Lab Chip · doi:10.1039/b609813d · Cited by 380
Self-citationXu, S., Liu, Y., Wang, T., & Li, J. (2011) · Analytical Chemistry · doi:10.1021/ac200237j · Cited by 367
Kartikasari, A. E. R., Huertas, C. S., Mitchell, A., & Plebanski, M. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.692142 · Cited by 343
“(113) used a range of hydrogel microparticles to analyze IL-2, IL-4, and TNF in complex media, simultaneously using high-velocity microfluidic scanning and reached LOD between 1-8 pg/ml.”
BackgroundMethodInfluentialGervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
Self-citationImmunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Bioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
A fully automated immunoassay from whole blood on a disc
Lee, B. S., Lee, J.-N., Park, J.-M., Lee, J.-G., Kim, S., Cho, Y.-K., & Ko, C. (2009) · Lab on a Chip · doi:10.1039/b820321k · Cited by 302
Hu, M., Yan, J., He, Y., Lu, H., Weng, L., Song, S., Fan, C., & Wang, L. (2010) · ACS Nano · doi:10.1021/nn901404h · Cited by 258
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51
Metadata
- Authors
- Cesaro-Tadic, S., Dernick, G., Juncker, D., Buurman, G., Kropshofer, H., Michel, B., Fattinger, C., & Delamarche, E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 4
- Issue
- 6
- Pages
- 563
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2155213995
- Cited by
- 203
- References
- 1
- FWCI
- 9.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.