The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
A hydrogel-based microfluidic device for the studies of directed cell migration
Abstract
We have developed a hydrogel-based microfluidic device that is capable of generating a steady and long term linear chemical concentration gradient with no through flow in a microfluidic channel. Using this device, we successfully monitored the chemotactic responses of wildtype Escherichia coli (suspension cells) to alpha-methyl-DL-aspartate (attractant) and differentiated HL-60 cells (a human neutrophil-like cell line that is adherent) to formyl-Met-Leu-Phe (f-MLP, attractant). This device advances the current state of the art in microchemotaxis devices in that (1) it demonstrates the validity of using hydrogels as the building material for a microchemotaxis device; (2) it demonstrates the potential of the hydrogel based microfluidic device in biological experiments since most of the proteins and nutrients essential for cell survival are readily diffusible in hydrogel; (3) it is capable of applying chemical stimuli independently of mechanical stimuli; (4) it is straightforward to make, and requires very basic tools that are commonly available in biological labs. This device will also be useful in controlling the chemical and mechanical environment during the formation of tissue engineered constructs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE CHEMOTACTIC EFFECT OF MIXTURES OF ANTIBODY AND ANTIGEN ON POLYMORPHONUCLEAR LEUCOCYTES
Boyden, S. (1962) · The Journal of Experimental Medicine · doi:10.1084/jem.115.3.453 · Cited by 2,733
Berg, H. C. (2025) · Princeton University Press eBooks · doi:10.1515/9780691279886 · Cited by 2,367
Collins, S. J., Ruscetti, F. W., Gallagher, R. E., & Gallo, R. C. (1978) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.75.5.2458 · Cited by 1,594
Making sense of it all: bacterial chemotaxis
Wadhams, G. H., & Armitage, J. P. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1524 · Cited by 1,489
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Ability of polymorphonuclear leukocytes to orient in gradients of chemotactic factors.
Zigmond, S. H. (1977) · The Journal of cell biology · doi:10.1083/jcb.75.2.606 · Cited by 907
Parent, C. A., & Devreotes, P. N. (1999) · Science · doi:10.1126/science.284.5415.765 · Cited by 890
Polarization of Chemoattractant Receptor Signaling During Neutrophil Chemotaxis
Servant, G., Weiner, O. D., Herzmark, P., Balla, T., Sedat, J. W., & Bourne, H. R. (2000) · Science · doi:10.1126/science.287.5455.1037 · Cited by 877
Chemotaxis: signalling the way forward
Van Haastert, P. J. M., & Devreotes, P. N. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1435 · Cited by 693
A new direct-viewing chemotaxis chamber
Zicha, D., Dunn, G. A., & Brown, A. F. (1991) · Journal of Cell Science · doi:10.1242/jcs.99.4.769 · Cited by 386
Receptor clustering and signal processing in E. coli chemotaxis
Sourjik, V. (2004) · Trends in Microbiology · doi:10.1016/j.tim.2004.10.003 · Cited by 354
A sensitive, versatile microfluidic assay for bacterial chemotaxis
Mao, H., Cremer, P. S., & Manson, M. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0931258100 · Cited by 332
Berg, H. C. (1975) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.04.060175.001003 · Cited by 301
Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator
Walker, G. M., Sai, J., Richmond, A., Stremler, M., Chung, C. Y., & Wikswo, J. P. (2005) · Lab on a Chip · doi:10.1039/b417245k · Cited by 266
Biochemistry and Biomechanics of Cell Motility
Li, S., Guan, J.-L., & Chien, S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100340 · Cited by 248
Characterization of a membrane-based gradient generator for use in cell-signaling studies
Abhyankar, V. V., Lokuta, M. A., Huttenlocher, A., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b514133h · Cited by 241
Diao, J., Young, L., Kim, S., Fogarty, E. A., Heilman, S. M., Zhou, P., Shuler, M. L., Wu, M., & DeLisa, M. P. (2006) · Lab Chip · doi:10.1039/b511958h · Cited by 239
Self-citationT cell chemotaxis in a simple microfluidic device
Lin, F., & Butcher, E. C. (2006) · Lab Chip · doi:10.1039/b607071j · Cited by 211
Irimia, D., Liu, S.-Y., Tharp, W. G., Samadani, A., Toner, M., & Poznansky, M. C. (2006) · Lab Chip · doi:10.1039/b511877h · Cited by 196
Wong, K., Pertz, O., Hahn, K., & Bourne, H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600092103 · Cited by 168
Measuring Chemotaxis and Chemokinesis: The Under-Agarose Cell Migration Assay
Heit, B., & Kubes, P. (2003) · Science Signaling · doi:10.1126/stke.2003.170.pl5 · Cited by 160
Diffusion Measurements in Agar Gel
Schantz, E. J., & Lauffer, M. A. (1962) · Biochemistry · doi:10.1021/bi00910a019 · Cited by 153
Micropatterned agarose gels for stamping arrays of proteins and gradients of proteins
Mayer, M., Yang, J., Gitlin, I., Gracias, D. H., & Whitesides, G. M. (2004) · PROTEOMICS · doi:10.1002/pmic.200300748 · Cited by 130
Frevert, C. W., Boggy, G. J., Keenan, T. M., & Folch, A. (2006) · Lab on a Chip · doi:10.1039/b515560f · Cited by 80
Chemotaxis Assays of Mouse Sperm on Microfluidic Devices
小山, 幸., Amarie, D., Soini, H. A., Novotný, M. V., & Jacobson, S. C. (2006) · Analytical Chemistry · doi:10.1021/ac052087i · Cited by 66
Meyer, W., & Howard, T. (1987) · Blood · doi:10.1182/blood.v70.2.363.363 · Cited by 38
Cited by
Hydrogel biomaterials: A smart future?
Kopeček, J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.044 · Cited by 1,003
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Sedimentation and Effective Temperature of Active Colloidal Suspensions
Palacci, J., Cottin-Bizonne, C., Ybert, C., & Bocquet, L. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.088304 · Cited by 525
Cell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
Collective Hydrodynamics of Swimming Microorganisms: Living Fluids
Koch, D. L., & Subramanian, G. (2011) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-121108-145434 · Cited by 433
Metadata
- Authors
- Cheng, S.-Y., Heilman, S., Wasserman, M., Archer, S., Shuler, M. L., & Wu, M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 6
- Pages
- 763
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2013717626
- Cited by
- 359
- References
- 26
- FWCI
- 13.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.